Analysis of a countable number of protein molecules released from living single cells was realized by a micro/nanofluidic device entirely integrating cellular processing and molecular processing into pL-microchannels and fL-nanochannels, respectively.
Nanofluidics have recently attracted significant attention with regard to the development of new functionalities and applications, and producing new functional devices utilizing nanofluidics will require the fabrication of nanochannels. Fused silica nanofluidic devices fabricated by top-down methods are a promising approach to realizing this goal. Our group previously demonstrated the analysis of a living single cell using such a device, incorporating nanochannels having different sizes (102–103 nm) and with branched and confluent structures and surface patterning. However, fabrication of geometrically-controlled nanochannels on the 101 nm size scale by top-down methods on a fused silica substrate, and the fabrication of micro-nano interfaces on a single substrate, remain challenging. In the present study, the smallest-ever square nanochannels (with a size of 50 nm) were fabricated on fused silica substrates by optimizing the electron beam exposure time, and the absence of channel breaks was confirmed by streaming current measurements. In addition, micro-nano interfaces between 103 nm nanochannels and 101 μm microchannels were fabricated on a single substrate by controlling the hydrophobicity of the nanochannel surfaces. A micro-nano interface for a single cell analysis device, in which a nanochannel was connected to a 101 μm single cell chamber, was also fabricated. These new fabrication procedures are expected to advance the basic technologies employed in the field of nanofluidics.
Understanding near-wall diffusion of small particles and biomolecules is important in colloid science and many microfluidic devices. Our experimental measurements of the diffusion of 110–460 nm radii suspended particles in the presence of electric fields up to 3.1 kV/m using particle tracking are in agreement with theoretical predictions for diffusion hindered by the presence of a solid surface. The results suggest that the external electric field has little, if any, effect upon the hindered diffusion of colloidal particles, even when the electrophoretic force exceeds the Stokes drag.
In the field of micro/nanofluidics, the channel open/close valves are among the most important technologies for switching and partitioning actions and integration of various operations into fluidic circuits. While several types of valves have been developed in microfluidics, few are capable in nanofluidics. In this study, we proposed a femtoliter (fL) volume nanochannel open/close valve fabricated in glass substrates. The valve consists of a shallow, circular and stepped-bottom valve chamber connected to nanochannels and an actuator. Even with tiny deformation occurring at the nanolevel in glass, an open/closed state of a nanochannel (10–1000 nm) can be achieved. We designed a fL-valve based on an analytical material deformation model, and developed a valve fabrication process. We then verified the open/closed state of the valve using a 308 fL-valve chamber with a four-stepped nanostructure fitting an arc-shape of deflected glass, confirmed its stability and durability over 50 open/close operations, and succeeded in stopping/flowing an aqueous solution at 209 fL s−1 under a 100 kPa pressure in a 900 nm nanochannel with a fast response of ∼0.65 s. A leak flow from the closed valve was sufficiently small even at a 490 kPa pressure-driven flow. Since the developed fL-valve can be applied to various nanofluidic devices made of glass and other rigid materials such as plastic, it is expected that this work will contribute significantly to the development of novel integrated micro/nanofluidics chemical systems for use in various applications, such as single cell/single molecule analysis.
The bonding of glass substrates is necessary when constructing micro/nanofluidic devices for sealing micro- and nanochannels. Recently, a low-temperature glass bonding method utilizing surface activation with plasma was developed to realize micro/nanofluidic devices for various applications, but it still has issues for general use. Here, we propose a simple process of low-temperature glass bonding utilizing typical facilities available in clean rooms and applied it to the fabrication of micro/nanofluidic devices made of different glasses. In the process, the substrate surface was activated with oxygen plasma, and the glass substrates were placed in contact in a class ISO 5 clean room. The pre-bonded substrates were heated for annealing. We found an optimal concentration of oxygen plasma and achieved a bonding energy of 0.33–0.48 J/m2 in fused-silica/fused-silica glass bonding. The process was applied to the bonding of fused-silica glass and borosilicate glass, which is generally used in optical microscopy, and revealed higher bonding energy than fused-silica/fused-silica glass bonding. An annealing temperature lower than 200 °C was necessary to avoid crack generation by thermal stress due to the different thermal properties of the glasses. A fabricated micro/nanofluidic device exhibited a pressure resistance higher than 600 kPa. This work will contribute to the advancement of micro/nanofluidics.