The premise that the virtual synchronous generator (VSG) can actively support the weak grid is that the VSG can operate stably. In this paper, the small-signal sequence impedance models of the voltage-controlled VSG and the current-controlled VSG are built and the sequence impedance characteristics of these two types of VSGs are compared and analyzed. The sequence impedance of the voltage-controlled VSG, being consistent with the grid impedance characteristics, is generally inductive. By contrast, the sequence impedance of the current-controlled VSG is mainly negative impedance in the middle- and high-frequency areas and the impedance amplitude is quite low. Based on the built sequence impedance models and the impedance stability criterion, the influence of the weakness of the grid on the stability of these two types of VSG grid-connected system is analyzed. The results of stability analysis show that the current-controlled VSG is prone to instability while the voltage-controlled VSG remains stable. Therefore, the voltage-controlled VSG is more suitable than the current-controlled VSG for grid-connected renewable energy generation in an ultra-weak grid from the point of view of system stability. Finally, experiment results validate the stability analysis.
18 May 2020 in IEEE Transactions on Sustainable Energy
This article proposes an unbalanced voltage compensation method for a dispersed wind farm (DWF) by cooperating permanent magnetic synchronous generators (PMSGs) with a star-connected cascaded H-bridges (CHB) static synchronous compensator (STATCOM). The topology of a typical DWF is given and the mathematical models of CHB-STATCOM and PMSG inverter are established to show that the unbalanced grid voltage can be suppressed by controlling their virtual negative-sequence output admittance (NSOA). The relationship between maximum phase voltage and dc voltage corresponding to zero-sequence voltage injection is obtained to quantitatively analyze the negative-sequence current injection ability of the CHB-STATCOM. Moreover, the phase current limit is introduced to address the over-current problem, and a virtual NSOA method for sharing unbalanced voltage is proposed. An allocation coefficient calculation method is also proposed in consideration of both remaining capacity and voltage unbalanced factor (VUF) for different PMSGs. Furthermore, a coordinated control strategy of PMSGs and CHB-STATCOM for unbalanced voltage suppression is proposed. The effectiveness of the proposed coordinated control strategy is verified by simulation on a 50 MW DWF with a ±5 MVar star-connected CHB-STATCOM.
31 January 2023 in IEEE Transactions on Power Electronics
Taking actual engineering as a case study, this article provides a novel scheme of applying the inductive power filtering method (IPFM) to resolve the harmonic resonance issues in large-scale photovoltaic (PV) plant. By using IPFM's special structure and dual zero-impedance design, the impedance network of large-scale PV plant is reshaped while the performance of power filters is improved, so that the harmonic resonance due to the interaction between the inverters and the power grid is suppressed. First, the topology and components of the IPFM-based large-scale PV plant are introduced. The three-phase mathematical model in harmonic domain is then established. Based on the deduced transfer matrix, the simplified circuit of the studied large-scale PV plant is obtained. Moreover, the IPFM's resonance damping mechanisms on resonant frequency shift and harmonic amplification mitigation are analyzed. Both simulation and engineering tests verify the feasibility of the proposal.
20 November 2018 in IEEE Transactions on Industry Applications
Harmonics in microgrids have attracted intensive power quality concern. It is analyzed in this paper that both currents in the voltage-controlled DG inverter side and the main grid side are easily involved in harmonic distortion due to nonlinear loads and background harmonics. To deal with this issue, a cooperative operation strategy for the DG inverters and a reactor-integrated hybrid active power filter (RIHAF) are proposed based on an integrated transformer-structured grid-connected microgrid. First, for the purpose of cost reduction and covering space saving, an integrated transformer based on a reactor integration technique (RIT) is conceived and the principle of the RIT is illustrated. To improve the current quality in the DG inverter side, a harmonic impedance reinforcement control method is employed to enhance the harmonic rejection performance of the voltage-controlled DG inverter. Besides, taking advantage of the integrated transformer, a RIHAF is proposed to suppress the current harmonics in the main grid side. Detailed simulation results show that current harmonics in both the DG inverter side and the main grid side can be simultaneously suppressed with the proposed cooperative operation strategy. Finally, experimental results from a scaled-down integrated transformer-structured microgrid platform are presented to verify the effectiveness of the RIT and the proposed cooperative operation strategy.
With the increasing use of sensitive loads in frequency converters and in relays in distribution networks, voltage sag has become a major power quality issue that urgently needs to be solved. For the purpose of improving the understanding of voltage sag severity in distribution networks, a comprehensive weight-based severity evaluation method of voltage sag is presented in this paper. First, a multi-side index system that takes into account the combined influence of the source, network, and the load is established. A comprehensive weight method, which combines the improved analytic hierarchy process (IAHP) and the entropy method, is then adopted to determine the index weight. The weight of each index and the degree of superiority are linearly weighted to obtain the severity of voltage sag at different observation points. Finally, the effectiveness of the proposed method is verified using a distribution network model established in DIgSILENT PowerFactory (15.1.7, Gomaringen, Germany).
To ensure safe and reliable operation, the ability to ride through various disturbances is vital for a microgrid with multi-inverters. As the voltage and frequency support comes from the power-electronic-based inverters, it is necessary to find a proper control strategy to improve the rejection ability of the DG inverter against disturbances. In this regard, this paper proposes a new distributed secondary frequency control approach for islanded microgrids, in which the main purpose is to remove the frequency deviation under droop control method with better disturbance rejection performance. Unlike many traditional approaches which rely on a detailed control model, the proposed one needs little model information thanks to the model-independent characteristic of active disturbance rejection control (ADRC) technique. A linear extended state observer is introduced to estimate the useless model dynamics (including unknown disturbances, unmodeled dynamics and nonlinear dynamics) which are then compensated in the control input. After the active compensation procedure, the nonlinear frequency control model can be converted into a quasi-linear model, based on which a proportional distributed control algorithm is established to restore the frequency and equalize the active power among the DGs. Simulation results based on a four-inverter-based microgrid show that the proposed approach achieves frequency restoration, active power sharing, as well as satisfactory disturbance rejection performance.