Integrated energy system is important for the high-efficient utilization of multitype energy systems. In this paper, the stochastic optimal operation is investigated for the micro integrated electric power, natural gas, and heat delivery system (IPGHS). First, a low-carbon micro-IPGHS is proposed with the comprehensive consideration of renewable generation, carbon-capture-based power-to-gas technology, and the combined power and heat units. Second, a scenario-based optimal operation model for micro-IPGHS is proposed to handle uncertainties in energy demand and renewable generation. In the proposed model, energy transactions between micro-IPGHS and upstream energy systems as well as constraints for battery storage, natural gas storage, and heat storage systems are considered. Finally, a case study is used for the proposed low-carbon micro-IPGHS to validate the optimal stochastic operation approach. The proposed integrated system can effectively utilize the variable clean energy for optimizing the delivery of the green operation in micro-IPGHS.
Fast and reliable service restoration strategy is necessary to restore as many out-of-service loads as possible in a short time. In this article, a mixed-integer second-order cone programming (MISOCP) formulation is proposed for service restoration of distribution network with distributed generations (DGs). This formulation relaxes the original non-convex power flow equations into conic quadratic format. The employment of the conic relaxation is of great importance because it ensures the quality of the obtained solution. The service restoration is formulated as a multi-objective optimization problem considering the minimization of de-energized loads and total number of switching operations. Moreover, PQ and PV model of DGs are considered in this formulation. The proposed method is tested on the 33-bus system and the Taiwan Power Company 84-bus system to show its effectiveness.
The ever-growing requirement for reliability and quality of power supply suggests to enable self-healing features of smart distribution network using intelligent communication and control. In this article, a concept of fully decentralized multi-agent system (FDMAS) automation is proposed to build a unified restoration service framework for distribution network with distribution generators (DGs), where an FDMAS interaction mechanism is designed for establishing a reduced model which can significantly reduce the computational dimensions of service restoration. Furthermore, an FDMAS-based strategy is proposed for service restoration by combining network reconfiguration with intentional islanding; especially a network reconfiguration algorithm based on network flow model is presented, which, along with parameter justification, can mitigate the variations of loads and intermittence of DGs. The simulation studies are carried out on the 84-bus and 22-bus distribution system respectively, using MATLAB and java agent development framework (JADE) simulation system and dynamic model test platform. The test results show that the proposed strategy can maximize restoration of out-of-service loads with minimum switching times and has an excellent performance on service restoration time.
20 February 2020 in IEEE Transactions on Power Systems
Linear power flow model is advantageous for the fast operational analysis and the efficient optimization of the power systems. In this letter, we propose a hybrid physical model-driven and data-driven approach for linearizing power flow model. In this proposed approach, the linear power flow model contains two parts, i.e., the existing physical-equation-based linear power flow model and the linearized error model. The linearized errors are obtained by the partial least squares regression based data-driven approach. The proposed linear power flow model can retain the useful inherent information from the physical model and utilize the ability of data analysis to extract the inexplicit linear relationship. Simulations on the four test systems have validated that the proposed hybrid linear model exhibits a much better performance on the branch power flow calculation than other linear power flow models.
31 August 2022 in IEEE Transactions on Sustainable Energy
With the increasing integration of the multi-energy microgrid (MEM) with the distribution network (DN), the distributed coordination between MEM and DN becomes critical. This paper proposes a distributed scheduling method for the coupled MEM-DN under operational uncertainties. First, a worst-expectation min-max-max-min robust optimization model is formulated for MEM considering the uncertainties of renewable distributed generation (wind and photovoltaic) as well as its class probability. Second, the column and constraint generation algorithm with an alternating iteration strategy (C&CG-AIS) is proposed to accelerate the solution by decoupling the subproblems. Third, the multi-interval convex hull uncertainty set (MCHUS) is proposed to reduce the conservatism of robust optimization by decreasing the low-probability scenarios. Furthermore, the Bregman alternating direction method with multipliers (BADMM) is combined with the alternating optimization procedure (AOP) to overcome the convergence difficulty in the nonconvex distributed MEM-DN model. Finally, the effectiveness of the proposed model and method is verified by simulation tests based on IEEE-33 node DN and a park-level MEM.
18 May 2020 in IEEE Transactions on Sustainable Energy
This article proposes an unbalanced voltage compensation method for a dispersed wind farm (DWF) by cooperating permanent magnetic synchronous generators (PMSGs) with a star-connected cascaded H-bridges (CHB) static synchronous compensator (STATCOM). The topology of a typical DWF is given and the mathematical models of CHB-STATCOM and PMSG inverter are established to show that the unbalanced grid voltage can be suppressed by controlling their virtual negative-sequence output admittance (NSOA). The relationship between maximum phase voltage and dc voltage corresponding to zero-sequence voltage injection is obtained to quantitatively analyze the negative-sequence current injection ability of the CHB-STATCOM. Moreover, the phase current limit is introduced to address the over-current problem, and a virtual NSOA method for sharing unbalanced voltage is proposed. An allocation coefficient calculation method is also proposed in consideration of both remaining capacity and voltage unbalanced factor (VUF) for different PMSGs. Furthermore, a coordinated control strategy of PMSGs and CHB-STATCOM for unbalanced voltage suppression is proposed. The effectiveness of the proposed coordinated control strategy is verified by simulation on a 50 MW DWF with a ±5 MVar star-connected CHB-STATCOM.