Julien Perchoux

Dr. Julien Perchoux

Laboratory of Analysis and Architecture of Systems, Institut National Polytechnique de Toulouse, 2 rue Camichel, 31500 Toulouse, France
orcid

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 July 2012 in Microfluidics and Nanofluidics
Verified
Journal Article
Closed access
PDF file
LCLucie Campagnolo
Lucie Campagnolo
MNMilan Nikolić
Milan Nikolić
JPJulien Perchoux
Julien Perchoux
YLYah Leng Lim
Yah Leng Lim
KBKarl Bertling
Karl Bertling
TBThierry Bosch
Thierry Bosch

26 November 2014 in Optics Express
Verified
Journal Article
Open access
PDF file
KBKarl Bertling
Karl Bertling
JPJulien Perchoux
Julien Perchoux
TTThomas Taimre
Thomas Taimre
RMRobert Malkin
Robert Malkin
DRDaniel Robert
Daniel Robert
TBThierry Bosch
Thierry Bosch
Optics InfoBase is the Optical Society's online library for flagship journals, partnered and copublished journals, and recent proceedings from OSA conferences.

9 June 2014 in Applied Optics
Verified
Journal Article
Closed access
PDF file
RKRussell Kliese
Russell Kliese
TTThomas Taimre
Thomas Taimre
ABAhmad Ashrif A Bakar
Ahmad Ashrif A Bakar
YLYah Leng Lim
Yah Leng Lim
KBKarl Bertling
Karl Bertling
ARAleksandar D. Rakić
Aleksandar D. Rakić
Self-mixing laser sensors show promise for a wide range of sensing applications, including displacement, velocimetry, and fluid flow measurements. Several techniques have been developed to simulate self-mixing signals; however, a complete and succinct process for synthesizing self-mixing signals has so far been absent in the open literature. This article provides a systematic numerical approach for the analysis of self-mixing sensors using the steady-state solution to the Lang and Kobayashi model. Examples are given to show how this method can be used to synthesize self-mixing signals for arbitrary feedback levels and for displacement, distance, and velocity measurement. We examine these applications with a deterministic stimulus and discuss the velocity measurement of a rough surface, which necessitates the inclusion of a random stimulus.

13 May 2016 in Sensors
Verified
Journal Article
Open access
PDF file
JPJulien Perchoux
Julien Perchoux
AQAdam QUOTB
Adam QUOTB
RAReza Atashkhooei
Reza Atashkhooei
FAFrancisco Azcona
Francisco Azcona
EMEvelio RAMIREZ MIQUET
Evelio RAMIREZ MIQUET
Santiago RoyoSantiago Royo
Santiago Royo
Optical feedback interferometry (OFI) sensors are experiencing a consistent increase in their applications to biosensing due to their contactless nature, low cost and compactness, features that fit very well with current biophotonics research and market trends. The present paper is a review of the work in progress at UPC-CD6 and LAAS-CNRS related to the application of OFI to different aspects of biosensing, both in vivo and ex vivo. This work is intended to present the variety of opportunities and potential applications related to OFI that are available in the field. The activities presented are divided into two main sensing strategies: The measurement of optical path changes and the monitoring of flows, which correspond to sensing strategies linked to the reconstruction of changes of amplitude from the interferometric signal, and to classical Doppler frequency measurements, respectively. For optical path change measurements, measurements of transient pulses, usual in biosensing, together with the measurement of large displacements applied to designing palliative care instrumentation for Parkinson disease are discussed. Regarding the Doppler-based approach, progress in flow-related signal processing and applications in real-time monitoring of non-steady flows, human blood flow monitoring and OFI pressure myograph sensing will be presented. In all cases, experimental setups are discussed and results presented, showing the versatility of the technique. The described applications show the wide capabilities in biosensing of the OFI sensor, showing it as an enabler of low-cost, all-optical, high accuracy biomedical applications.

5 October 2016 in Optics Express
Verified
Journal Article
Open access
PDF file
YZYU ZHAO
YU ZHAO
JPJulien Perchoux
Julien Perchoux
LCLucie Campagnolo
Lucie Campagnolo
TCThierry Camps
Thierry Camps
RAReza Atashkhooei
Reza Atashkhooei
VBVeronique Bardinal
Veronique Bardinal
Optical feedback interferometry (OFI) performance for microscale-flow sensing is studied theoretically and experimentally. A new numerical modeling approach for OFI flow meter spectrum reproduction is presented in this work to study the optical effect on the signal due to the micro-scale channel geometry. Two well-defined frequency peaks are found in the OFI spectrum, this phenomenon can be attributed to the reflection of the forward scattered light on the channel rear interface. The flow rate measurement shows good accuracy over a range of fluid velocities from 16.8 mm/s to 168 mm/s, thus providing a promising tool to study and to optimize the OFI microfluidic sensor system.

9 January 2015 in Applied Optics
Verified
Journal Article
Open access
PDF file
JRJalal Al Roumy
Jalal Al Roumy
JPJulien Perchoux
Julien Perchoux
YLYah Leng Lim
Yah Leng Lim
TTThomas Taimre
Thomas Taimre
ARAleksandar D. Rakić
Aleksandar D. Rakić
TBThierry Bosch
Thierry Bosch
We present a simple analytical model that describes the injection current and temperature dependence of optical feedback interferometry signal strength for a single-mode laser diode. The model is derived from the Lang and Kobayashi rate equations, and is developed both for signals acquired from the monitoring photodiode (proportional to the variations in optical power) and for those obtained by amplification of the corresponding variations in laser voltage. The model shows that both the photodiode and the voltage signal strengths are dependent on the laser slope efficiency, which itself is a function of the injection current and the temperature. Moreover, the model predicts that the photodiode and voltage signal strengths depend differently on injection current and temperature. This important model prediction was proven experimentally for a near-infrared distributed feedback laser by measuring both types of signals over a wide range of injection currents and temperatures. Therefore, this simple model provides important insight into the radically different biasing strategies required to achieve optimal sensor sensitivity for both interferometric signal acquisition schemes.