José D. Gutiérrez-Cano

Mr. José D. Gutiérrez-Cano

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 July 2015 in IEEE Transactions on Microwave Theory and Techniques
Verified
Journal Article
Closed access
JCJose M. Catala-Civera
Jose M. Catala-Civera
ACAntoni J. Canos
Antoni J. Canos
PPPedro Plaza-Gonzalez
Pedro Plaza-Gonzalez
JGJosé D. Gutiérrez-Cano
José D. Gutiérrez-Cano
Beatriz Garcia-BanosBeatriz Garcia-Banos
Beatriz Garcia-Banos
FPFelipe L. Penaranda-Foix
Felipe L. Penaranda-Foix
A microwave cavity and heating system for microwave processing and in situ dynamic measurements of the complex permittivity of dielectric materials at high temperatures ( ~ 1000 ° C) has been developed. The method is based on a dual-mode cylindrical cavity where heating and testing are performed by two different swept frequency microwave sources. A cross-coupling filter isolates the signals coming from both sources. By adjusting the frequency bandwidth of the heating source and the level of coupling to the cavity, an automatic procedure allows for the establishment of a desirable level of heating rate to the dielectric sample to reach high temperatures in short cycles. Dielectric properties of materials as a function of temperature are calculated by an improved cavity perturbation method during heating. Accuracy of complex permittivity results has been evaluated and an error lower than 5% with respect to a rigorous analysis of the cavity has been achieved. The functionality of the microwave dielectric measurement system has been demonstrated by heating and measuring glass and ceramic samples up to 1000 ° C. The correlation of the complex permittivity with the heating rate, temperature, absorbed power, and other processing parameters can help to better understand the interactions that take place during microwave heating of materials at high temperatures compared to conventional heating.

1 June 2017 in Journal of Food Engineering
Verified
Journal Article
Closed access
JGJosé D. Gutiérrez-Cano
José D. Gutiérrez-Cano
JCJosé M. Catalá-Civera
José M. Catalá-Civera
JBJohn Bows
John Bows
FPFelipe L. Peñaranda-Foix
Felipe L. Peñaranda-Foix

11 January 2017 in IEEE Transactions on Microwave Theory and Techniques
Verified
Journal Article
Closed access
DMDavid Marques-Villarroya
David Marques-Villarroya
Felipe L. Penaranda-FoixFelipe L. Penaranda-Foix
Felipe L. Penaranda-Foix
Beatriz Garcia-BanosBeatriz Garcia-Banos
Beatriz Garcia-Banos
JCJose M. Catala-Civera
Jose M. Catala-Civera
JGJosé D. Gutiérrez-Cano
José D. Gutiérrez-Cano
An enhanced full-wave method based on circuit analysis is presented in this paper, where the whole set of modes TE mnp and TM mnp are taken into account. The modeling of a split cylinder resonator is done with two circuit networks of one and three ports, characterized by their generalized admittance matrix, which is computed making use of the mode matching method. The improved full-wave circuit method has been applied to the accurate determination of dielectric properties of materials. The proposed method has been validated through comparisons with other published models and also with measurements.

1 September 2018 in Journal of Food Engineering
Verified
Journal Article
Open access
JGJosé D. Gutiérrez-Cano
José D. Gutiérrez-Cano
IHIan E. Hamilton
Ian E. Hamilton
JCJosé M. Catalá-Civera
José M. Catalá-Civera
JBJohn Bows
John Bows
FPFelipe L. Peñaranda-Foix
Felipe L. Peñaranda-Foix

2 February 2022 in Sensors
Verified
Journal Article
Open access
PDF file
JGJosé D. Gutiérrez-Cano
José D. Gutiérrez-Cano
JCJOSE MANUEL CATALA CIVERA
JOSE MANUEL CATALA CIVERA
ALAngel M. López-Buendía
Angel M. López-Buendía
PPPedro J. Plaza-González
Pedro J. Plaza-González
Felipe L. Penaranda-FoixFelipe L. Penaranda-Foix
Felipe L. Penaranda-Foix
The identification of the minerals composing rocks and their dielectric characterization is essential for the utilization of microwave energy in the rock industry. This paper describes the use of a near-field scanning microwave microscope with enhanced sensitivity for non-invasive measurements of permittivity maps of rock specimens at the micrometer scale in non-contact mode. The microwave system comprises a near-field probe, an in-house single-port vectorial reflectometer, and all circuitry and software needed to make a stand-alone, portable instrument. The relationship between the resonance parameters of the near-field probe and the dielectric properties of materials was determined by a combination of classical cavity perturbation theory and an image charge model. The accuracy of this approach was validated by a comparison study with reference materials. The device was employed to determine the permittivity maps of a couple of igneous rock specimens with low-loss and high-loss minerals. The dielectric results were correlated with the minerals comprising the samples and compared with the dielectric results reported in the literature, with excellent agreements.

21 October 2013 in IEEE Transactions on Microwave Theory and Techniques
Verified
Journal Article
Closed access
AMAntoni Josep Canos Marin
Antoni Josep Canos Marin
Beatriz Garcia-BanosBeatriz Garcia-Banos
Beatriz Garcia-Banos
JCJOSE MANUEL CATALA CIVERA
JOSE MANUEL CATALA CIVERA
Felipe L. Penaranda-FoixFelipe L. Penaranda-Foix
Felipe L. Penaranda-Foix
JGJosé D. Gutiérrez-Cano
José D. Gutiérrez-Cano
An improvement of the accuracy of dielectric measurements of the open-ended coaxial resonator method is described. The technique is based on an empirical technique for de-embedding the coupling network excited by electric probes. By this procedure, the influence of the coupling structure on the resonance can be precisely eliminated independently of the coupling conditions, which guarantees a high accuracy in the permittivity determination of materials by open-ended coaxial resonators. The technique is applicable to materials with a wide range of dielectric constants and losses. The results of dielectric measurements are compared with those obtained using other standard methods.