Antoni Josep Canos Marin

Antoni Josep Canos Marin

Auto-generated profile, based on publicly available information

Antoni Josep Canos Marin

Instituto ITACA, Universitat Politècnica de València, Valencia, Spain

Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 July 2015 in IEEE Transactions on Microwave Theory and Techniques
Verified
Journal Article
Closed access
JCJose M. Catala-Civera
Jose M. Catala-Civera
ACAntoni J. Canos
Antoni J. Canos
PPPedro Plaza-Gonzalez
Pedro Plaza-Gonzalez
JGJosé D. Gutiérrez-Cano
José D. Gutiérrez-Cano
Beatriz Garcia-BanosBeatriz Garcia-Banos
Beatriz Garcia-Banos
FPFelipe L. Penaranda-Foix
Felipe L. Penaranda-Foix
A microwave cavity and heating system for microwave processing and in situ dynamic measurements of the complex permittivity of dielectric materials at high temperatures ( ~ 1000 ° C) has been developed. The method is based on a dual-mode cylindrical cavity where heating and testing are performed by two different swept frequency microwave sources. A cross-coupling filter isolates the signals coming from both sources. By adjusting the frequency bandwidth of the heating source and the level of coupling to the cavity, an automatic procedure allows for the establishment of a desirable level of heating rate to the dielectric sample to reach high temperatures in short cycles. Dielectric properties of materials as a function of temperature are calculated by an improved cavity perturbation method during heating. Accuracy of complex permittivity results has been evaluated and an error lower than 5% with respect to a rigorous analysis of the cavity has been achieved. The functionality of the microwave dielectric measurement system has been demonstrated by heating and measuring glass and ceramic samples up to 1000 ° C. The correlation of the complex permittivity with the heating rate, temperature, absorbed power, and other processing parameters can help to better understand the interactions that take place during microwave heating of materials at high temperatures compared to conventional heating.

7 August 2006 in IEEE Transactions on Microwave Theory and Techniques
Verified
Journal Article
Closed access
ACA.J. Canos
A.J. Canos
JCJOSE MANUEL CATALA CIVERA
JOSE MANUEL CATALA CIVERA
Felipe L. Penaranda-FoixFelipe L. Penaranda-Foix
Felipe L. Penaranda-Foix
EREdl. Reyes-Davo
Edl. Reyes-Davo
A novel technique to extract the influence of coupling networks on the resonant frequency of cavities in one-port measurements is presented. The determination of the unloaded resonant frequency is performed directly from measurements without either the need to obtain the electromagnetic fields in the resonator or to deembed the delay of transmission lines from the measuring equipment to the resonator. The importance of the Foster's form on the modeling of the frequency detuning of the resonators is also discussed and a criterion for the choice of the appropriate Foster's form is suggested. The procedure is validated with simulations and experimental measurements of manufactured cavities

12 July 2012 in IEEE Transactions on Microwave Theory and Techniques
Verified
Journal Article
Closed access
Felipe L. Penaranda-FoixFelipe L. Penaranda-Foix
Felipe L. Penaranda-Foix
MJMichael D. Janezic
Michael D. Janezic
JCJOSE MANUEL CATALA CIVERA
JOSE MANUEL CATALA CIVERA
ACAntoni J. Canos
Antoni J. Canos
In this paper, a full-wave method for the electromagnetic analysis of dielectric-loaded cylindrical and coaxial waveguides and cavities is developed. For this purpose, a new four-port ring network is proposed, and the mode-matching method is applied to calculate the generalized admittance matrix of this new structure. A number of analyses on dielectric-loaded waveguide structures and cavities have been conducted in order to validate and to assess the accuracy of the new approach. The results have been compared with theoretical values, numerical modeling from the literature, and data from commercial electromagnetic simulators. The method has been also applied to the accurate determination of dielectric properties, and we provide an example of these measurements as another way to validate this new method.

11 April 2005 in Measurement Science and Technology
Verified
Journal Article
Closed access
Beatriz Garcia-BanosBeatriz Garcia-Banos
Beatriz Garcia-Banos
JCJOSE MANUEL CATALA CIVERA
JOSE MANUEL CATALA CIVERA
ACAntoni J Canós
Antoni J Canós
Felipe L. Penaranda-FoixFelipe L. Penaranda-Foix
Felipe L. Penaranda-Foix

21 October 2013 in IEEE Transactions on Microwave Theory and Techniques
Verified
Journal Article
Closed access
AMAntoni Josep Canos Marin
Antoni Josep Canos Marin
Beatriz Garcia-BanosBeatriz Garcia-Banos
Beatriz Garcia-Banos
JCJOSE MANUEL CATALA CIVERA
JOSE MANUEL CATALA CIVERA
Felipe L. Penaranda-FoixFelipe L. Penaranda-Foix
Felipe L. Penaranda-Foix
JGJosé D. Gutiérrez-Cano
José D. Gutiérrez-Cano
An improvement of the accuracy of dielectric measurements of the open-ended coaxial resonator method is described. The technique is based on an empirical technique for de-embedding the coupling network excited by electric probes. By this procedure, the influence of the coupling structure on the resonance can be precisely eliminated independently of the coupling conditions, which guarantees a high accuracy in the permittivity determination of materials by open-ended coaxial resonators. The technique is applicable to materials with a wide range of dielectric constants and losses. The results of dielectric measurements are compared with those obtained using other standard methods.

10 June 2010 in IEEE Sensors Journal
Verified
Journal Article
Closed access
Beatriz Garcia-BanosBeatriz Garcia-Banos
Beatriz Garcia-Banos
ACAntoni J. Canos
Antoni J. Canos
Felipe L. Penaranda-FoixFelipe L. Penaranda-Foix
Felipe L. Penaranda-Foix
JCJOSE MANUEL CATALA CIVERA
JOSE MANUEL CATALA CIVERA
A microwave sensor system for the noninvasive monitoring of the curing process of a thermoset material placed inside a metallic mold is described. The microwave sensor is designed as an open-ended coaxial resonator with a curved surface adapted to the mold inner shape. The analysis of the microwave resonator comprises a recently developed method for deembedding the effect of coupling network in overcoupled resonators, so the range of permitted measurements encompass both low and high dielectric losses of polymeric materials. Results show that noninvasive, continuous monitoring of the microwave dielectric properties of the thermoset material can be performed in real time, allowing one to check initial conditions and to verify the evolution of the cure process.