Nikola Simic

Mr. Nikola Simic


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 October 2021 in Energies
Verified
Journal Article
Open access
PDF file
NSNikola Simic
Nikola Simic
Luka StrezoskiLuka Strezoski
Luka Strezoski
BDBoris Dumnic
Boris Dumnic
Since microgrids should be able to smoothly operate in two distinct modes—grid-connected and islanded, their fault currents can widely fluctuate depending on the operational mode. When the microgrid is connected to the grid, the highest fault current, by far, is supplied by the utility grid. In this mode, the fault current contribution from distributed energy resources (DERs) is less than 20%. However, when the microgrid switches to the islanded mode, the fault current contribution from the utility grid is lost and DERs are the sole fault current sources. Thus, the overall fault current in the islanded mode is multiple times lower when compared to the grid connected mode. Moreover, most of the DERs are inverter-based, with limited fault currents, which further reduces the overall fault current in the islanded mode. With the rapid rise of the microgrid penetration around the globe, this phenomenon can adversely influence the relay protection, and thus the microgrid fault current needs to be precisely analyzed. Therefore, the main purpose of this paper is to thoroughly analyze the fault current differences in two distinct operation modes of a microgrid, and to consequently derive conclusions regarding the required improvements in fault calculations and relay protection analysis in emerging microgrids. A representative microgrid test bed is developed and modelled using the in-house developed software as well as in a state-of-the-art hardware-in-the-loop environment. Several different short-circuit faults were simulated and analyzed in both grid-connected and islanded modes. The results show that the fault currents significantly differ depending on the operating mode, and thus highly influence the protection system. Moreover, test results show that the fault calculation algorithms aimed at radial distribution grids, mostly used for microgrid fault calculations in the available literature, need to be further improved to provide precise and time-efficient results when the emerging microgrids are considered. These results provide a valuable insight into the current state of the microgrids’ fault calculation and protection and reveal several important directions for future research.

1 January 2024 in Journal of Modern Power Systems and Clean Energy
Verified
Journal Article
Closed access
Luka StrezoskiLuka Strezoski
Luka Strezoski
NSNikola Simic
Nikola Simic
KLKenneth A. Loparo
Kenneth A. Loparo
In this paper, a robust method for quantifying the impact of short-circuit faults on microgrids is proposed. Microgrids can operate in both islanded (grid-forming) and grid-connected (grid-following) modes, and the ownership and responsibility for the microgrid operation can vary significantly from distribution system operators (DSOs) to third-party microgrid operators. This necessitates the development of a robust short-circuit calculation (SCC) method that can provide accurate results for all the possible microgrid topologies, operational modes, and ownership models. Unlike previously developed SCC methods for microgrids, the SCC method proposed in this paper provides highly accurate results for all possible microgrid topologies: islanded microgrid, grid-connected microgrid, and utility microgrid as a part of a larger distribution grid. In addition, the proposed SCC method solves the short-circuit faults of any complexity, with the same simplicity. The proposed SCC method is tested on a complete model of a real-life microgrid on the Case Western Reserve University campus, operating in both islanded and grid-connected modes. The computational results show the advantages of the proposed SCC method in comparison to the previous ones for microgrids, regarding the robustness (ability to solve complex short-circuit faults with an arbitrary number of faulted buses and phases that affect a microgrid of any topology), as well as the accuracy of the results.

1 December 2021 in Energija Ekonomija Ekologija
Verified
Journal Article
Closed access
NSNikola Simic
Nikola Simic
Luka StrezoskiLuka Strezoski
Luka Strezoski
SSSimiša Simić
Simiša Simić
DČDušan Čohadžić
Dušan Čohadžić
The emerging microgrids are mainly powered by renewable distributed energy resources (DERs), such as solar and wind, with batteries as a backup power. These DERs are decoupled from the grid by inverters and thus, their fault currents are dictated by the control strategies programmed in the inverter itself. The inverters’ control strategies are in most cases dictated by the Grid Code requirements, in order to help the microgrid ride through the fault as painless as possible. Thus, in order to have accurate results for microgrid fault calculations, crucially important for setting the relay protection and protecting the entire microgrid, these DERs must be accurately modelled. Unfortunately, these models have not yet been fully developed nor standardized. In this paper, a recently developed model for inverter-based DERs are integrated into the fault current calculation based on the IEC 60909 standard for fault calculations and tested in the state-of-the-art hardware-in-the-loop environment. The test results are very promising, which opens the possibility to standardize these novel models, filling the seriously dangerous gap of not having the standardized fault models for inverter-based DERs.