23 September 2019 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
Luka StrezoskiLuka Strezoski
Luka Strezoski
BDBoris Dumnic
Boris Dumnic
BPBane Popadic
Bane Popadic
MPMarija Prica
Marija Prica
KLKenneth A. Loparo
Kenneth A. Loparo
In this paper, novel models for electronically coupled distributed energy resources (ECDERs) for online fault calculations of large-scale systems are proposed. ECDERs have different fault responses than traditional synchronous and induction (AC) machines, and generally accepted models for these emerging DERs do not exist. The deployment of ECDERs is constantly increasing worldwide and there is an urgent need for developing appropriate models for fault calculations. In order to have fast calculations, applicable to large-scale systems, the dynamic behavior of traditional AC machines have been approximated in three steady state time-periods (sub-transient, transient, and steady-state). Accordingly, the online fault calculations of large-scale systems have been conducted for these three periods. To simulate the ECDERs' dynamic behavior, and develop models that are compliant with traditional fault calculations, fault models of ECDERs in the sub-transient, transient, and steady-state periods are proposed, with a short peak current period included in the proposed models during the sub-transient period. To validate the proposed models, they are integrated into recently developed online fault calculations, and tested on various large-scale systems. Results from computer simulations are compared with results obtained using state-of-the-art laboratory equipment, as well as with relevant reports on fault current contributions of ECDERs. The results match very well, further validating the proposed models.

27 February 2019 in Energies
Verified
Journal Article
Open access
PDF file
MŽMatej Žnidarec
Matej Žnidarec
Zvonimir KlaićZvonimir Klaić
Zvonimir Klaić
Damir ŠljivacDamir Šljivac
Damir Šljivac
BDBoris Dumnic
Boris Dumnic
Expanding the number of photovoltaic (PV) systems integrated into a grid raises many concerns regarding protection, system safety, and power quality. In order to monitor the effects of the current harmonics generated by PV systems, this paper presents long-term current harmonic distortion prediction models. The proposed models use a multilayer perceptron neural network, a type of artificial neural network (ANN), with input parameters that are easy to measure in order to predict current harmonics. The models were trained with one-year worth of measurements of power quality at the point of common coupling of the PV system with the distribution network and the meteorological parameters measured at the test site. A total of six different models were developed, tested, and validated regarding a number of hidden layers and input parameters. The results show that the model with three input parameters and two hidden layers generates the best prediction performance.

5 October 2021 in Energies
Verified
Journal Article
Open access
PDF file
NSNikola Simic
Nikola Simic
Luka StrezoskiLuka Strezoski
Luka Strezoski
BDBoris Dumnic
Boris Dumnic
Since microgrids should be able to smoothly operate in two distinct modes—grid-connected and islanded, their fault currents can widely fluctuate depending on the operational mode. When the microgrid is connected to the grid, the highest fault current, by far, is supplied by the utility grid. In this mode, the fault current contribution from distributed energy resources (DERs) is less than 20%. However, when the microgrid switches to the islanded mode, the fault current contribution from the utility grid is lost and DERs are the sole fault current sources. Thus, the overall fault current in the islanded mode is multiple times lower when compared to the grid connected mode. Moreover, most of the DERs are inverter-based, with limited fault currents, which further reduces the overall fault current in the islanded mode. With the rapid rise of the microgrid penetration around the globe, this phenomenon can adversely influence the relay protection, and thus the microgrid fault current needs to be precisely analyzed. Therefore, the main purpose of this paper is to thoroughly analyze the fault current differences in two distinct operation modes of a microgrid, and to consequently derive conclusions regarding the required improvements in fault calculations and relay protection analysis in emerging microgrids. A representative microgrid test bed is developed and modelled using the in-house developed software as well as in a state-of-the-art hardware-in-the-loop environment. Several different short-circuit faults were simulated and analyzed in both grid-connected and islanded modes. The results show that the fault currents significantly differ depending on the operating mode, and thus highly influence the protection system. Moreover, test results show that the fault calculation algorithms aimed at radial distribution grids, mostly used for microgrid fault calculations in the available literature, need to be further improved to provide precise and time-efficient results when the emerging microgrids are considered. These results provide a valuable insight into the current state of the microgrids’ fault calculation and protection and reveal several important directions for future research.

9 April 2019 in Energies
Verified
Journal Article
Open access
PDF file
BDBoris Dumnic
Boris Dumnic
BPBane Popadic
Bane Popadic
DMDragan Mitar Milicevic
Dragan Mitar Milicevic
NVNikola D. Vukajlovic
Nikola D. Vukajlovic
Marko DelimarMarko Delimar
Marko Delimar
The development in distributed energy resources technology has led to a significant amount of non-linear power electronics converters to be integrated in the power system. Although this leads to a more sustainable system, it also can have adverse impacts on system stability and energy power quality. More importantly, the majority of the distribution power systems currently are unbalanced (with asymmetrical voltages) due to load unbalance, while the most common fault types are unbalanced grid faults that can have many adverse effects on distributed resource operations. In that regard, proper control of the grid connected converters in active unbalanced distribution systems will become very important. This paper aims to present the behavior of the advanced grid connected converter control technique under different voltage states at the point of common coupling (according to the ABC classification). The main insufficiencies of the classical control technique will be highlighted, while the paper will propose an appropriate solution for mitigation of negative sequence currents under asymmetrical voltages at the point of common coupling. An extensive experimental verification of the proposed techniques is performed using an advanced laboratory prototype for research in grid integration of distributed resources. The experimental verification clearly demonstrates the benefits offered by the advanced control strategy.

14 September 2020 in Energies
Verified
Journal Article
Open access
PDF file
ZCZoltan Corba
Zoltan Corba
BPBane Popadic
Bane Popadic
DMDragan Mitar Milicevic
Dragan Mitar Milicevic
BDBoris Dumnic
Boris Dumnic
Vladimir KatićVladimir Katić
Vladimir Katić
Partial shading conditions of photovoltaic (PV) modules often occurs in urban areas leading to losses in electricity power generation of the PV power plant. The purpose of this study is to present how the PV power plant with high value of inverter power sizing factor (Kinv) can achieve high performance and power production under partial shading conditions with high shading losses. In this paper the results of long-term monitoring, performance analysis and experimental results are presented, while the results are compared to the estimated values calculated using PVsyst software. The study focused on the PV power plant at the Faculty of Technical Sciences (FTS) in Novi Sad, Republic of Serbia, for the period between the years 2012 and 2019. It has been shown that the values of PV power plant performance parameters are better than expected (very high), and resemble the power plants operating without shading. The high value of the inverter power sizing factor may lead to occasional saturation of the inverter when certain conditions are met, but most of the times it allows the inverter to operate at a more optimal power level. PV module soiling and power degradation is within the limits mentioned in the literature. The increase in Kinv in the partial shading conditions favorably affects the performance, does not degrade the efficiency of the inverter at saturation, reduces the effect of soiling and aging of PV modules, leading to higher power production.

1 October 2012 in Journal of Applied Research and Technology
Verified
Journal Article
Open access
PDF file
BDBoris Dumnic
Boris Dumnic
VKV. Katic
V. Katic
VVV. Vasic
V. Vasic
DMD. Milicevic
D. Milicevic
Marko DelimarMarko Delimar
Marko Delimar
This paper describes an improved sensorless vector control strategy for a squirrel cage induction generator used invariable speed wind energy conversion systems (WECS). The main goal is to design a robust control algorithmimmune to generator parameter variations. In order to estimate the rotational speed of the induction generator, amodel reference adaptive system (MRAS observer) is used. It is shown that a generator parameter mismatch has agreat influence on the rotor speed estimation. In order to estimate the speed accurately, the generator statorresistance must be identified at the same time to correct the mismatched resistance value used in the observer. Theproposed rotor speed estimator with parallel stator resistance identification is first verified by computer simulation.Finally, the experiment is conducted in order to verify the obtained simulation results. It is proved that this controlscheme can enhance the efficiency of a variable speed WECS.