Qing Zeng

Qing Zeng


Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2015 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Closed access
QZQing Zeng
Qing Zeng
XXXiu-Li Xie
Xiu-Li Xie
QCQian Chen
Qian Chen
To analyze causes leading to explantation and exchange of Implantable Collamer Lens phakic intraocular lenses (pIOLs) and examine the surgical techniques of pIOL exchange. Wuhan Aier Eye Hospital, Wuhan, China. Retrospective analysis of prospectively collected data. Different techniques were used to explant the pIOLs based on the amount of vaulting. Preoperative and postoperative data were collected to evaluate possible causes leading to pIOL exchange and the safety of pIOL exchange. Of 616 myopic eyes with previous pIOL implantation, 16 eyes of 15 patients having pIOL exchange were reviewed. Eight surgeries (50%) were performed because of low vaulting (≤100 μm) and another 8 (50%) because of too high vaulting (≥1000 μm). The causes leading to low vaulting included increased crystalline lens thickness (≥4.0 mm), low anterior chamber depth (ACD) (<3.1 mm), and a too-small pIOL (<12.0 mm). The high vaulting was primarily the result of oversized white-to-white (WTW) measurements with Scheimpflug pachymetry (Pentacam) or the use of a digital caliper by an unskilled examiner and of ciliary body cysts. Six months after pIOL exchange, the vaulting ranged from 162 to 715 μm. No anterior subcapsular cataracts or other complications occurred during the observation period. The main causes of abnormal vaulting and subsequent pIOL exchange included a thick crystalline lens, low ACD, too-small pIOL, WTW measurement error, and ciliary body cysts. Phakic IOL explantations were individually designed based on the vaulting to achieve proper safety and efficacy. No author has a financial or proprietary interest in any material or method mentioned.

1 June 2020 in Journal of Refractive Surgery
Verified
Journal Article
Closed access
PDF file
QCQian Chen
Qian Chen
WTWeina Tan
Weina Tan
XLXiaohua Lei
Xiaohua Lei
CPChao Pan
Chao Pan
LJLina Jin
Lina Jin
ZWZheng Wang
Zheng Wang
PURPOSE: To determine the factors related to the ciliary body that are predictive of outcomes of excessive vault (> 1,000 µm) after Implantable Collamer Lens (ICL V4c; STAAR Surgical) implantation. METHODS: In this retrospective case-control study, 27 eyes of 27 patients who presented with excessive vault (> 1,000 µm) following implantation of an ICL V4c were matched in a 1:2 ratio with those who presented with a normal vault (250 to 1,000 µm) on white-to-white distance, anterior chamber depth, and ICL size. The preoperative biometric parameters and clinical outcomes were compared between the two groups. The relationship between the postoperative vault and various variables was assessed by multiple linear regression analysis. Conditional logistic regression models were used to estimate odds ratios (ORs) and 95% CIs for excessive vault. RESULTS: The vault value 1 month postoperatively was associated with preoperative anterior chamber volume, iris-ciliary angle, and crystalline lens rise ( P < .05). In the conditional regression logistic analysis, every 1° reduction in iris-ciliary angle was associated with 4% increased odds of vault greater than 1,000 µm (OR = 0.96; 95% CI = 0.93 to 0.99; P < .001) and the anteriorly positioned ciliary body was associated with an increased risk of excessive vault after ICL implantation (OR = 3.57; 95% CI = 1.67 to 7.63; P < .001). In the excessive vault group, 1 eye underwent the ICL extraction and 3 eyes had an ICL exchange for a smaller ICL. After the ICL exchange, the mean value of postoperative vault decreased from 1,525.67 ± 468.22 to 810.33 ± 254.92 µm. CONCLUSIONS: Eyes with an anteriorly positioned ciliary body were associated with a higher rate of excessive vault after ICL implantation, so the size of the ICL may need to be adjusted in these patients. Assessment of ciliary body characteristics adds significant information to the prediction of excessive vault after surgery. [ J Refract Surg . 2020;36(6):380–387.]

1 December 2021 in Frontiers in Medicine
Verified
Journal Article
Open access
WYWanju Yang
Wanju Yang
YLYanzhu Luo
Yanzhu Luo
SWShangcao Wu
Shangcao Wu
XNXiaoxia Niu
Xiaoxia Niu
YYYanshuang Yan
Yanshuang Yan
QZQing Zeng
Qing Zeng
Purpose: To conduct a multi-center analysis and assess the economic burden due to dry eye disease (DED) in China.Design: A retrospective and cross-sectional study.Methods: Patients (n = 598) with diagnosed DED were recruited from 3 eye centers (in central, southeast, and northeast China) from 1 January 2018 to 31 December 2018. Data were collected regarding the examination, pharmacological therapy, and non-pharmacological therapy fees. Sub-group analyses were stratified by eye center, DED severity, types of DED, number of visits to physicians, and residential area. A logistic regression analysis was conducted to investigate the variables influencing total costs.Results: The per capita costs devoted to DED at the 3 centers were 422.6, 391.3, and 265.4 USD, respectively. The costs of non-pharmacological therapy accounted the largest part in three centers (75.6, 76.4, 76.5%, respectively). Patients with severe DED sustained the largest economic burden. Patients with mixed type of DED spent the most comparing to patients with either evaporative or aqueous-deficient types of DED. Patients spent more during the first visit compared with subsequent visits. Patients living in urban areas spent significantly more than did those living in rural areas (P = 0.001). The logistics regression analysis showed that total costs were significantly influenced by DED severity, number of visits to physicians, and area of residence (beta = 2.83, 0.83, 1.48; P < 0.0001).Conclusions: DED is a chronic ocular disease that timely non-cost counseling, early diagnosis, and efficacious treatment can reduce its economic burden on patients and the society.

11 April 2019 in BioMed Research International
Verified
Journal Article
Open access
PSpeng song
peng song
ZSZhuo Sun
Zhuo Sun
SRShengwei Ren
Shengwei Ren
KYKaili Yang
Kaili Yang
GDGuohua Deng
Guohua Deng
YSYajie Sun
Yajie Sun
Purpose. To investigate the effect of preoperative treatment and postoperative enhanced anti-inflammatory treatment on alleviating meibomian gland dysfunction (MGD) and dry eye induced by cataract surgery. Design. Prospective, randomized clinical trial. Methods. A total of 120 cataract patients with moderate obstructive-MGD were enrolled and randomized with 60:30:30 number of patients in cohorts I, II, and III, respectively: Cohort I: routine postoperative anti-inflammatory treatment; Cohort II: preoperative treatment (warming compress, lid hygiene, and anti-inflammatory treatment) and routine postoperative anti-inflammatory treatment; Cohort III: enhanced postoperative anti-inflammatory treatment. Main Outcomes Measures. All participants were examined preoperatively and postoperatively for ocular symptom score (OSS), noninvasive keratographic tear break-up time (NIKBUT), corneal fluorescein staining, Schirmer I test, lid margin, meibum quality and expressibility, and meibomian gland dropout. Results. Ocular surface disorders and MGD showed aggravated status at 1 month postoperatively in Cohort I and Cohort III, and the aggravated MGD resolved by 3 months postoperatively. At 1 month postoperatively, Cohort II and Cohort III presented high NIKBUT and low OSS, lid margin, and meibum quality and expressibility (Cohort II vs Cohort I: all P<0.001, respectively; Cohort III vs Cohort I: P=0.011, P=0.024, P=0.046, P=0.045, and P=0.012, respectively). Additionally, Cohort II had better outcomes of lid margin and meibum quality and expressibility than Cohort III at 1 month postoperatively (P=0.031, P=0.026, and P<0.001, respectively). At 3 months postoperatively, Cohort II presented a significantly higher NIKBUT than Cohort I and Cohort III (P<0.001 and P=0.001, respectively). Conclusion. Preoperative management of MGD is effective and optimal in alleviating obstructive-MGD and dry eye induced by cataract surgery.

1 April 2023 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Closed access
WTWeina Tan
Weina Tan
QCQian Chen
Qian Chen
RYRuibo Yang
Ruibo Yang
ZWZheng Wang
Zheng Wang
QZQing Zeng
Qing Zeng
SZShaozhen Zhao
Shaozhen Zhao
Purpose: To assess the position of implantable collamer lens (ICL) haptic after ICL V4C implantation using standardized panoramic ultrasound bimicroscopy (UBM), to analyze its characteristics, associated factors, and the relationship with the clinical vault quantitatively. Setting: Hankou Aier Eye Hospital, Wuhan, Hubei, China. Design: Cross-sectional study. Methods: 167 subjects (323 eyes) implanted with ICL V4C who had a 3-month follow-up with UBM examination were included in this study. The relative position of ICL to the adjacent structure and ICL haptic-related parameters (the final tip point of ICL haptic [ftICL haptic], measured from the scleral spur to the final tip of the ICL haptic, the posterior of the ICL to ICL haptic [ICL arc], measured from the posterior surface of the ICL to the ICL haptic plane, and the height of the crystalline lens from the ICL haptic (lens arc), measured from the anterior surface of the crystalline lens to the ICL haptic plane and other parameters), were estimated on the UBM image. Eyes were divided into 3 subgroups according to the ftICL haptic (Group 1: ≤0.5 mm; Group 2: 0.5 to 1.0 mm; and Group 3:≥1.0 mm, respectively), and the factors associated with the ICL haptic-related parameters and their impact on the clinical vault were evaluated. Results: The haptics could be imaged in the ciliary sulcus, on the ciliary body, and under the ciliary body in 629 (48.7%), 525 (40.6%), and 138 (10.7%) eyes, respectively. The ftICL haptic and the summation of ICL arc and lens arc showed a correlation with the clinical vault (r = −0.34, P = .00; r = 0.87, P = .00). When the ftICL haptic results were divided into 3 groups, the percentage of eyes that exhibited clinical vault >750 μm were lowest in Group 3. Multivariate regression analysis showed spherical equivalent, white-to-white (WTW), anterior chamber volume (ACV) and iris–ciliary angle (ICA); the difference between the implanted ICL size and horizontal sulcus-to-sulcus (ICL size-STS) were associated with the ftICL haptic. The IOP, WTW, ACV, and the ICL size-STS were significantly associated with ICL arc, while the ICA and lens rise were associated with lens arc. Conclusions: The position of ICL haptic was associated with the clinical vault. Its quantitative evaluation may provide valuable information to help clinicians to select the best ICL size before surgery and understand the formation of clinical vault after surgery.

29 March 2022 in Scientific Reports
Verified
Journal Article
Open access
PDF file
PSPeng Song
Peng Song
SRShengwei Ren
Shengwei Ren
YLYu Liu
Yu Liu
PLPei Li
Pei Li
QZQing Zeng
Qing Zeng
Early detection of keratoconus is a crucial factor in monitoring its progression and making the decision to perform refractive surgery. The aim of this study was to use the decision tree technique in the classification and prediction of subclinical keratoconus (SKC). A total of 194 eyes (including 105 normal eyes and 89 with SKC) were included in the double-center retrospective study. Data were separately used for training and validation databases. The baseline variables were derived from tomography and biomechanical imaging. The decision tree models were generated using Chi-square automatic interaction detection (CHAID) and classification and regression tree (CART) algorithms based on the training database. The discriminating rules of the CART model selected metrics of the Belin/Ambrósio deviation (BAD-D), stiffness parameter at first applanation (SPA1), back eccentricity (Becc), and maximum pachymetric progression index in that order; On the other hand, the CHAID model selected BAD-D, deformation amplitude ratio, SPA1, and Becc. Further, the CART model allowed for discrimination between normal and SKC eyes with 92.2% accuracy, which was higher than that of the CHAID model (88.3%), BAD-D (82.0%), Corvis biomechanical index (CBI, 77.3%), and tomographic and biomechanical index (TBI, 78.1%). The discriminating performance of the CART model was validated with 92.4% accuracy, while the CHAID model was validated with 86.4% accuracy in the validation database. Thus, the CART model using tomography and biomechanical imaging was an excellent model for SKC screening and provided easy-to-understand discriminating rules.