Zheng Wang

Zheng Wang

Auto-generated profile, based on publicly available information

Zheng Wang

Department of Refractive Surgery, Guangzhou Aier Eye Hospital, Jinan University, Guangzhou, China

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2020 in Journal of Refractive Surgery
Verified
Journal Article
Closed access
PDF file
QCQian Chen
Qian Chen
WTWeina Tan
Weina Tan
XLXiaohua Lei
Xiaohua Lei
CPChao Pan
Chao Pan
LJLina Jin
Lina Jin
ZWZheng Wang
Zheng Wang
PURPOSE: To determine the factors related to the ciliary body that are predictive of outcomes of excessive vault (> 1,000 µm) after Implantable Collamer Lens (ICL V4c; STAAR Surgical) implantation. METHODS: In this retrospective case-control study, 27 eyes of 27 patients who presented with excessive vault (> 1,000 µm) following implantation of an ICL V4c were matched in a 1:2 ratio with those who presented with a normal vault (250 to 1,000 µm) on white-to-white distance, anterior chamber depth, and ICL size. The preoperative biometric parameters and clinical outcomes were compared between the two groups. The relationship between the postoperative vault and various variables was assessed by multiple linear regression analysis. Conditional logistic regression models were used to estimate odds ratios (ORs) and 95% CIs for excessive vault. RESULTS: The vault value 1 month postoperatively was associated with preoperative anterior chamber volume, iris-ciliary angle, and crystalline lens rise ( P < .05). In the conditional regression logistic analysis, every 1° reduction in iris-ciliary angle was associated with 4% increased odds of vault greater than 1,000 µm (OR = 0.96; 95% CI = 0.93 to 0.99; P < .001) and the anteriorly positioned ciliary body was associated with an increased risk of excessive vault after ICL implantation (OR = 3.57; 95% CI = 1.67 to 7.63; P < .001). In the excessive vault group, 1 eye underwent the ICL extraction and 3 eyes had an ICL exchange for a smaller ICL. After the ICL exchange, the mean value of postoperative vault decreased from 1,525.67 ± 468.22 to 810.33 ± 254.92 µm. CONCLUSIONS: Eyes with an anteriorly positioned ciliary body were associated with a higher rate of excessive vault after ICL implantation, so the size of the ICL may need to be adjusted in these patients. Assessment of ciliary body characteristics adds significant information to the prediction of excessive vault after surgery. [ J Refract Surg . 2020;36(6):380–387.]

1 November 2020 in Journal of Refractive Surgery
Verified
Journal Article
Closed access
PDF file
JWJiawei Wu
Jiawei Wu
LXLu Xiong
Lu Xiong
ZWZheng Wang
Zheng Wang
DRDan Z. Reinstein
Dan Z. Reinstein
RVRyan S. Vida
Ryan S. Vida
TATimothy J. Archer
Timothy J. Archer
PURPOSE: To describe the visual outcomes of correcting moderate to high hyperopia after two different surgical procedures of lenticular implantation. METHODS: This prospective small case series study used epikeratophakia combined with transepithelial phototherapeutic keratectomy (PTK-EP) and femtosecond laser–assisted lenticule intrastromal keratoplasty (LIKE) using myopic small incision lenticule extraction (SMILE)–derived refractive lenticule for correcting hyperopia ranging from +3.00 to +10.00 diopters (D). The implanted refractive lenticule was matched with the recipient's manifest refraction. The visual, refractive, corneal tomographic, and epithelial thickness outcomes were analyzed after surgery. RESULTS: Four eyes underwent PTK-EP and 6 eyes underwent LIKE. At the last postoperative visit, 6 of 10 eyes had uncorrected distance visual acuity equal to or better than the preoperative corrected distance visual acuity (CDVA). No eyes lost one line or more of CDVA postoperatively. Postoperative spherical equivalent was within ±0.50 D of the target for 9 of 10 eyes. Posterior corneal curvature slightly steepened for PTK-EP and LIKE. Postoperative epithelial thickness demonstrated the expected doughnut pattern in both groups characterized by epithelium in the central zone (5 mm) thinner than that in the peripheral zone (5 to 7 mm). CONCLUSIONS: Visual outcomes, refraction, posterior corneal surface changes, and epithelial remodeling after PTKEP or LIKE show a potentially useful modality for correcting moderate to high hyperopia. [ J Refract Surg . 2020;36(11):772–779.]

20 November 2024 in Ophthalmology
Verified
Journal Article
Open access
YWYan Wang
Yan Wang
LXLixin Xie
Lixin Xie
KYKe Yao
Ke Yao
WSWalter Sekundo
Walter Sekundo
JAJorge L. Alió
Jorge L. Alió
ZDZhiyu Du
Zhiyu Du
Development of evidence-based guidelines for keratorefractive lenticule extraction (KLEx). Keratorefractive lenticule extraction refers to various corneal refractive procedures involving removal of refractive lenticules of intrastromal corneal tissue, typically through a small incision, eliminating creation of a corneal flap. This technique has gained popularity rapidly; however, no clinical practice guidelines exist. These evidence-based guidelines were developed following the World Health Organization guidebook using the Appraisal of Guidelines for Research and Evaluation II tool and adhering to the Reporting Items for Practice Guideline in Healthcare statement. The body of evidence was drawn from 8 literature databases, 5 clinical guideline databases, and 2 academic organizations. Recommendations were developed via a Delphi consensus of 44 global experts in refractive surgery, cornea, retina, glaucoma, and optometry. The certainty of evidence, balance of benefits and harms, patient preferences and values, and economic evaluations were considered fully. The Grading of Recommendations Assessment, Development, and Evaluation approach was used to assess evidence quality and recommendation strengths. From 385 initial clinical questions, 15 were identified, prompting a review of 250 717 studies, with 609 included for conducting and updating 26 and 2 systematic reviews, respectively. Subsequently, consensus was reached on 38 recommendations for preoperative screening, candidate selection, intraoperative quality control, operating principles, postoperative monitoring, and complication management. For KLEx, an effective and accurate refractive correction is attributed to various factors such as corneal thickness, degree of myopia, treatment nomogram, and optical zone. For complications that could affect vision, comprehensive and effective management strategies were proposed, particularly for wrong-plane dissection and difficult lenticule removal, suction loss, and perioperative infection. Customized surgical planning protocols and operative techniques were analyzed. Among all recommendations, 29 (76%) were labelled as strong, each externally reviewed. The corneal biomechanical properties may help to improve safety and predictability, although they need further validation. Several research gaps for enhancing KLEx safety were also revealed. These guidelines provide evidence-based recommendations for KLEx in clinical practice, such as for preoperative screening for keratoconus, surgical planning, and management and prevention of complications and infection. The guidelines are expected to minimize the complications and achieve better outcomes. Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.

1 February 2019 in Journal of Refractive Surgery
Verified
Journal Article
Closed access
PDF file
LFLimin Fan
Limin Fan
LXLu Xiong
Lu Xiong
BZBo Zhang
Bo Zhang
ZWZheng Wang
Zheng Wang
PURPOSE: To observe the epithelial remodeling over a 9-mm diameter cornea induced by topography-guided femtosecond laser–assisted in situ keratomileusis (FS-LASIK) for myopia correction using spectral-domain optical coherence tomography (SD-OCT). METHODS: Forty-three eyes of 22 patients who underwent topography-guided FS-LASIK for myopic correction were included. The “Pachymetrywide” scan pattern was used to generate the epithelial thickness map using SD-OCT preoperatively and 1, 3, and 6 months postoperatively. Epithelial thickness was compared and analyzed by section and zone. RESULTS: Compared to the preoperative values, the change in the average epithelial thickness in the central, paracentral, and mid-peripheral zones was 2.09, 4.53, and −0.87 µm at 1 month; 3.00, 4.61, and −0.97 µm at 3 months; and 3.28, 4.55, and −0.81 µm at 6 months postoperatively, respectively. From 1 to 3 months postoperatively, the central epithelial thickness changed significantly ( P = .021), whereas the epithelial thickness in the paracentral ( P = .973) and mid-peripheral ( P = .996) zones stabilized. No significant epithelial thickness change was observed in the zones between 3 and 6 months postoperatively (all P > .05). The epithelial thickness in the paracentral inferotemporal section increased by 12.7% at 6 months after surgery. The central epithelial hyperplasia showed no correlation with the change in postoperative manifest refraction spherical equivalent ( P = .313). CONCLUSIONS: After topography-guided FS-LASIK, the 9-mm diameter epithelial thickness showed a longitudinal and regional non-uniform redistribution. Central epithelial remodeling stabilized more slowly. The greatest increase in epithelial thickness was observed in the paracentral inferotemporal section. This epithelial remodeling did not cause refractive regression. [ J Refract Surg . 2019;35(2):88–95.]

1 April 2023 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Closed access
WTWeina Tan
Weina Tan
QCQian Chen
Qian Chen
RYRuibo Yang
Ruibo Yang
ZWZheng Wang
Zheng Wang
QZQing Zeng
Qing Zeng
SZShaozhen Zhao
Shaozhen Zhao
Purpose: To assess the position of implantable collamer lens (ICL) haptic after ICL V4C implantation using standardized panoramic ultrasound bimicroscopy (UBM), to analyze its characteristics, associated factors, and the relationship with the clinical vault quantitatively. Setting: Hankou Aier Eye Hospital, Wuhan, Hubei, China. Design: Cross-sectional study. Methods: 167 subjects (323 eyes) implanted with ICL V4C who had a 3-month follow-up with UBM examination were included in this study. The relative position of ICL to the adjacent structure and ICL haptic-related parameters (the final tip point of ICL haptic [ftICL haptic], measured from the scleral spur to the final tip of the ICL haptic, the posterior of the ICL to ICL haptic [ICL arc], measured from the posterior surface of the ICL to the ICL haptic plane, and the height of the crystalline lens from the ICL haptic (lens arc), measured from the anterior surface of the crystalline lens to the ICL haptic plane and other parameters), were estimated on the UBM image. Eyes were divided into 3 subgroups according to the ftICL haptic (Group 1: ≤0.5 mm; Group 2: 0.5 to 1.0 mm; and Group 3:≥1.0 mm, respectively), and the factors associated with the ICL haptic-related parameters and their impact on the clinical vault were evaluated. Results: The haptics could be imaged in the ciliary sulcus, on the ciliary body, and under the ciliary body in 629 (48.7%), 525 (40.6%), and 138 (10.7%) eyes, respectively. The ftICL haptic and the summation of ICL arc and lens arc showed a correlation with the clinical vault (r = −0.34, P = .00; r = 0.87, P = .00). When the ftICL haptic results were divided into 3 groups, the percentage of eyes that exhibited clinical vault >750 μm were lowest in Group 3. Multivariate regression analysis showed spherical equivalent, white-to-white (WTW), anterior chamber volume (ACV) and iris–ciliary angle (ICA); the difference between the implanted ICL size and horizontal sulcus-to-sulcus (ICL size-STS) were associated with the ftICL haptic. The IOP, WTW, ACV, and the ICL size-STS were significantly associated with ICL arc, while the ICA and lens rise were associated with lens arc. Conclusions: The position of ICL haptic was associated with the clinical vault. Its quantitative evaluation may provide valuable information to help clinicians to select the best ICL size before surgery and understand the formation of clinical vault after surgery.

28 August 2020 in BMC Ophthalmology
Verified
Journal Article
Open access
PDF file
QCQian Chen
Qian Chen
QZQing Zeng
Qing Zeng
ZWZheng Wang
Zheng Wang
CPChao Pan
Chao Pan
XLXiaohua Lei
Xiaohua Lei
WTWeina Tan
Weina Tan
Background: This is a case of spontaneous toric implantable collamer lens (TICL) rotation that occurred twice in the left eye of a patient. Case presentation: A 24-year-old gentleman received TICL implantation for treatment of myopic astigmatism encountered with spontaneous rotation of approximately 90° from its original position. TICL reposition procedure was performed with visual outcome of 20/16. Surprisingly, a re-rotation of TICL occurred. The patient underwent a replacement of non-toric ICL with a larger size after careful re-evaluation with final visual outcome of 20/20. A short and small ciliary process with shallow ciliary sulcus and posteriorly positioned ciliary body was found by Ultrasound Biomicroscopy (UBM). Conclusions: The unique morphology of the ciliary body may have a potential association with the vault and instability of implanted ICL. Careful examination of the ciliary body morphology is essential in preoperative evaluation.