Xiao Su

Dr. Xiao Su


Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 September 2025 in Buildings
Verified
Journal Article
Open access
PDF file
DCDun Cao
Dun Cao
XLXiaona Li
Xiaona Li
XSXiao Su
Xiao Su
YDYanqiang Di
Yanqiang Di
YLYanyi Li
Yanyi Li
YCYansu Chen
Yansu Chen
Building geometric parameters are key factors influencing energy-efficient building design. However, the systematic influence of building geometric parameters on energy use intensity (EUI) across varying climate regions and building envelope thermal performance levels remains incompletely elucidated, hindering the quantitative assessment of their energy-saving benefits in diverse regions and operational scenarios. This study employs a zonal sensor-optimized coupled daylighting–thermal simulation to analyze the impact of building geometric parameters and their values on annual total EUI across different climate regions and building envelope thermal performance levels. The interquartile range (IQR), sensitivity analysis (SA), and energy saving rate (ESR) analysis are utilized. The results showed the following: (1) The energy-saving benefits of geometric parameters were the greatest in severe cold (SevC) and temperate regions (TRs), with IQRs ranging from 28.50 to 39.87 kWh/m2, followed by hot summer–warm winter (HS-WW), cold (Cld), and hot summer–cold winter (HS-CW) regions. While high-performance building envelopes significantly reduce EUI, the energy-saving benefits associated with geometric parameters remain undiminished. (2) The WWR is the parameter most sensitive to EUI, with SA reaching a maximum of 41.19%, notably exceeding 20% in HS-CW regions, HS-WW regions, and TRs; floor height has the lowest sensitivity, with SA reaching a maximum of 5.65%. (3) In different climate regions, the influence of floor height and building footprint area on the ESR shifts between positive and negative correlations, while the WWR and window sill height consistently exhibit positive correlations with the ESR in all climate regions. This study provides a quantitative decision-making basis for optimizing building geometric parameters in different climate regions to achieve high-performance building shapes during the early stages of architectural design.

26 March 2025 in Buildings
Verified
Journal Article
Open access
PDF file
ZHZhanguo Hao
Zhanguo Hao
RHRibo Hu
Ribo Hu
YGYi Gao
Yi Gao
JLJinyuan Liu
Jinyuan Liu
XSXiao Su
Xiao Su
With the increasing global demand for sustainable energy, energy conservation and efficiency in buildings located in severe cold climate regions have attracted considerable research attention. Conventional exterior wall insulation and energy utilization strategies in such environments often fail to achieve the desired levels of efficiency, energy conservation, and productivity. To address these challenges, this study proposes a thermoelectric power generation–wall system (TEPG–Wall System) designed specifically for prefabricated buildings. The system utilizes Ni90Cr10-Ni45Cu55 thermoelectric material, integrated with a wall collector cavity design, to harness the temperature difference between indoor and outdoor environments for electricity generation. Through software simulations and experimental investigations, the thermoelectric performance of the system under severe cold climate conditions was analyzed. With only 15 parallel devices, the system achieved an average output power of 0.02 W under typical operating conditions, corresponding to an annual energy output of approximately 0.0586 kWh. Such an energy output is sufficient to power low-power building equipment.

9 January 2026 in Coatings
Verified
Journal Article
Open access
PDF file
XWXin Wen
Xin Wen
SWShiqiang Wang
Shiqiang Wang
YMYi Meng
Yi Meng
DCDian Dian Chen
Dian Dian Chen
XSXiao Su
Xiao Su
Soot particle deposition is a common form of surface contamination in enclosed architectural environments and can significantly alter the optical appearance of painted surfaces. In the Zhaomiao temple halls of Inner Mongolia, long-term exposure to soot generated by butter lamps and incense burning has led to pronounced color darkening of mural pigments. To clarify the mechanisms by which soot deposition affects pigment optical behavior, this study investigates the surface deposition-induced color degradation of mineral pigment coatings, using Zhaomiao temple murals as a representative application context. Thirty-six typical mineral pigments were prepared as standardized coating specimens, and controlled soot deposition experiments were conducted to simulate progressive particulate accumulation on pigment surfaces. Variations in Commission Internationale de l’Éclairage (CIE) XYZ tristimulus values, luminance, and color difference (ΔE) were quantitatively analyzed under different soot-loading conditions. The results show systematic luminance attenuation and chromatic compression with increasing soot deposition, indicating that optical degradation is primarily governed by surface absorption and scattering effects introduced by carbonaceous particles. These results establish a quantitative framework based on measurable optical parameters—rather than a single absolute value—for evaluating particulate-induced optical degradation of pigment coatings. This study provides a quantitative basis for evaluating particulate-induced optical degradation of pigment coatings and supports surface condition assessment and digital reconstruction of soot-contaminated painted surfaces in architectural contexts such as the Zhaomiao temples.