Yanqiang Di

Dr. Yanqiang Di


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 August 2023 in Buildings
Verified
Journal Article
Open access
PDF file
YDYanqiang Di
Yanqiang Di
CZChen Zhao
Chen Zhao
XLXueli Lian
Xueli Lian
XLXiaolong Li
Xiaolong Li
DBDaorina Bao
Daorina Bao
JLJinxing Liu
Jinxing Liu
Low air temperature and frosting have been reported as the critical factors that greatly attenuate the efficiency and performance of the ASHP in cold regions. In order to ensure the potential prevalence of the ASHP in cold regions of China, a new ultra-low temperature ASHP unit was developed, and the field measurement was carried out in an office building where these ASHP units were installed in Shanxi Province. Results showed that a coefficient of performance (COP) of 1.83 was obtained at the ultra-low environmental temperature of −25 °C. Meanwhile, measured results indicated significant frosting suppression and improved heating performance under three typical frosting conditions. In addition, long-term measurement results revealed that the mean COP and COPsys reached up to 3.34 and 2.63, respectively, indicating a higher performance in the cold regions of China. Consequently, the corresponding CO2 emission reached 11.3 kg per year and per square meter, and the annual total cost on the unit reduced by 15.8% compared with the conventional ASHP, which meant that the total investment could be covered in the second year. The reduced CO2 emission and the annual cost implied that the ASHP unit could produce better environmental and economic benefits. Findings of this study revealed that this ultra-low temperature ASHP unit had a better performance under cold environment, which offered a possibility for the prevailing of the ASHP in cold or extremely cold regions, as well as could contribute to the carbon peaking and neutralization.

26 September 2023 in Sustainability
Verified
Journal Article
Open access
PDF file
QWQingqin Wang
Qingqin Wang
XSXiaofeng Sun
Xiaofeng Sun
RWRuonan Wang
Ruonan Wang
LZLining Zhou
Lining Zhou
HZHaizhu Zhou
Haizhu Zhou
QZQi Zhang
Qi Zhang
Rational planning and the use of renewable energy are effective means to reduce urban carbon emissions. In view of the few urban renewable energy planning cases and unclear methods, the paper takes the Sino-Singapore Tianjin Eco-City renewable energy planning project as a case to provide a renewable energy planning method under the guidance of carbon constraints. Based on scenario analysis, the energy demand of urban buildings, industry and transportation is analyzed and predicted. On the basis of meeting the needs of terminal energy use, with the goal of reducing carbon emissions, the renewable energy planning scheme from 2021 to 2050 under the low-carbon scenario has been formulated, including the promotion of energy-efficient buildings, the utilization of renewable energy in buildings, the electrification of terminal energy use, and the application of large-scale municipal renewable energy. It is planned that, by 2050, the overall renewable energy utilization rate of the Sino-Singapore Tianjin Eco-City will reach 76.76%. It will use renewable energy to heat about 60 million square meters, generate about 766 million kWh of electricity, save about 0.723 million tons of standard coal and reduce 1.287 million tons of carbon dioxide every year, which will have a good effect of energy conservation and emission reduction. In this paper, the renewable energy planning method under the guidance of carbon constraint is established, which can achieve the purposes of saving resources, protecting the environment and driving sustainable development. The Sino-Singapore Tianjin Eco-City is an international co-creation city, which will receive extensive attention and provide theoretical guidance and demonstration cases for urban renewable energy planning in the context of carbon peak and carbon neutrality in the new era.

27 January 2024 in Buildings
Verified
Journal Article
Open access
PDF file
YDYanqiang Di
Yanqiang Di
HDHaiyan Di
Haiyan Di
CZChen Zhao
Chen Zhao
ZLZichen Lu
Zichen Lu
XLXiaona Li
Xiaona Li
JLJuan Leng
Juan Leng
The applications of conventional heat pipes have been hindered by a few weaknesses, such as the low heat recovery effectiveness, the cross-pollution of fresh and exhaust air, and the difficult switch modes between winter and summer working conditions. In order to find solutions for those problems, a three-dimensional heat pipe exchanger was developed, and an experimental platform was built to test the heat recovery effectiveness of this heat pipe exchanger under different working conditions. Moreover, the operating performances of the three-dimensional heat pipe exchanger unit were monitored throughout one year in a hospital located in the hot summer and cold winter region of China. The field measurement results indicated that the heat recovery effectiveness could be effectively improved by reducing the air volume and the up-wind speed, increasing the cold air and hot air inlet temperature, and increasing the rows of pipes. According to optimizing the structure and operation parameters, the heat recovery efficiencies of the three-dimensional heat pipe exchanger increased by 65~85%. The recommended operation parameters of the three-dimensional heat pipe exchanger in winter and summer for indoor exhaust air temperature were 20 ± 2 °C and 22 ± 2 °C, respectively. The heat recovery effectiveness could reach up to 66% and 64.5% when the indoor and outdoor air temperature differences were higher than 11 °C and 5 °C in winter and summer, respectively. This study provides effective, reliable, and easily implementable methods for the application of three-dimensional heat pipe heat recovery devices in building HVAC systems. It offers guidance for the future design of heat pipe heat recovery devices.

4 September 2025 in Buildings
Verified
Journal Article
Open access
PDF file
DCDun Cao
Dun Cao
XLXiaona Li
Xiaona Li
XSXiao Su
Xiao Su
YDYanqiang Di
Yanqiang Di
YLYanyi Li
Yanyi Li
YCYansu Chen
Yansu Chen
Building geometric parameters are key factors influencing energy-efficient building design. However, the systematic influence of building geometric parameters on energy use intensity (EUI) across varying climate regions and building envelope thermal performance levels remains incompletely elucidated, hindering the quantitative assessment of their energy-saving benefits in diverse regions and operational scenarios. This study employs a zonal sensor-optimized coupled daylighting–thermal simulation to analyze the impact of building geometric parameters and their values on annual total EUI across different climate regions and building envelope thermal performance levels. The interquartile range (IQR), sensitivity analysis (SA), and energy saving rate (ESR) analysis are utilized. The results showed the following: (1) The energy-saving benefits of geometric parameters were the greatest in severe cold (SevC) and temperate regions (TRs), with IQRs ranging from 28.50 to 39.87 kWh/m2, followed by hot summer–warm winter (HS-WW), cold (Cld), and hot summer–cold winter (HS-CW) regions. While high-performance building envelopes significantly reduce EUI, the energy-saving benefits associated with geometric parameters remain undiminished. (2) The WWR is the parameter most sensitive to EUI, with SA reaching a maximum of 41.19%, notably exceeding 20% in HS-CW regions, HS-WW regions, and TRs; floor height has the lowest sensitivity, with SA reaching a maximum of 5.65%. (3) In different climate regions, the influence of floor height and building footprint area on the ESR shifts between positive and negative correlations, while the WWR and window sill height consistently exhibit positive correlations with the ESR in all climate regions. This study provides a quantitative decision-making basis for optimizing building geometric parameters in different climate regions to achieve high-performance building shapes during the early stages of architectural design.

18 August 2026 in Sustainability
Verified
Journal Article
Open access
PDF file
DBDaorina Bao
Daorina Bao
GYGuangqiang Yu
Guangqiang Yu
SZShaohua Zhang
Shaohua Zhang
YTYuang Tang
Yuang Tang
YDYanqiang Di
Yanqiang Di
CZChuanjiu Zhang
Chuanjiu Zhang
Degraded industrial sites in arid and semi-arid regions often suffer from loose surface substrates, weak water-retention capacity, high wind-erosion risk, and poor early vegetation establishment. Combining photovoltaic (PV) deployment with ecological utilization may improve near-surface habitats by shading, reducing wind speed, and regulating soil heat and moisture. This study investigated an ash storage yard of a coal-fired power plant in Ordos, Inner Mongolia, China, by comparing soil temperature, soil moisture, and near-surface wind-speed responses under three representative fixed PV tilt angles of 36°, 43°, and 50°, together with the corresponding early plant-growth suitability. A multi-physics model coupling near-surface airflow, water-vapor transport, and porous-media hydrothermal migration was established. A Gaussian suitability function combined with AHP-CRITIC weighting was used to construct a model-based comprehensive growth index (CGI) from soil temperature and moisture, while short-term field monitoring was used to validate afternoon soil hydrothermal trends. Among the three scenarios, the 36° configuration produced the widest horizontal heat–moisture-affected zone and the highest CGI values for alfalfa and Elymus nutans, reaching 0.7741 and 0.6875, respectively. Relative to the outside reference area, the rear PV zone reduced the near-surface wind speed by 33–40% and increased the plant heights of alfalfa and Elymus nutans by 49.4% and 37.8%, respectively. A first-order PVsyst assessment showed that the 43° configuration achieved the highest specific energy yield of 1814 kWh kWp−1 year−1, whereas the annual grid-connected output at 36° was only 0.59% lower. These findings indicate that the 36° configuration may provide a favorable compromise between early vegetation establishment and photovoltaic electricity generation among the tested scenarios. By linking renewable-energy production with microenvironment regulation and early vegetation establishment, the proposed framework provides a decision basis for the multifunctional and sustainable reuse of degraded industrial land. Nevertheless, the results represent a site-specific, single-season assessment and should not be interpreted as a universal optimum.

27 November 2022
Verified
Book Chapter
Closed access
PDF file
HLHe Long
He Long
YDYanqiang Di
Yanqiang Di
YGYafeng Gao
Yafeng Gao
CZChen Zhao
Chen Zhao
SKShuting Kong
Shuting Kong