Milan  Srndovic

Milan Srndovic

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 November 2017 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
MSMilan Srndovic
Milan Srndovic
AZAidar Zhetessov
Aidar Zhetessov
Tohid AlizadehTohid Alizadeh
Tohid Alizadeh
YFYakov L. Familiant
Yakov L. Familiant
Gabriele GrandiGabriele Grandi
Gabriele Grandi
ARAlexander Ruderman
Alexander Ruderman
Power electronic converters for medium and high power / voltage applications employ low frequency fundamental switching frequencies and therefore minimize switching losses. There are two main control techniques of switching angle estimation - Total Harmonic Distortion (THD) minimization and Selective Harmonic Elimination (SHE). In case of the first control technique, the switching angles are found based on the THD minimization without being specifically focused on eliminating some exact harmonics. For the SHE control technique, all degrees of freedom, due to available number of switching angles, are used for the elimination of certain low order harmonics. The basic idea of combining those two control techniques consists of using some degrees of freedom for eliminating certain harmonics and using the others for minimizing the remaining THD content. This generalized problem formulation includes classic minimal THD and SHE problems as special cases. Theoretical developments are verified by the set of experimental cases for the voltage and current THDs selecting characteristic working points over the modulation index range.

23 February 2018 in Energies
Verified
Journal Article
Open access
PDF file
MVMarija Vujacic
Marija Vujacic
MHManel Hammami
Manel Hammami
MSMilan Srndovic
Milan Srndovic
Gabriele GrandiGabriele Grandi
Gabriele Grandi
The three-phase voltage source inverter (VSI) is de facto standard in power conversion systems. To realize high power density systems, one of the items to be correctly addressed is the design and selection of the dc-link capacitor in relation to the voltage switching ripple. In this paper, effective formulas for designing the dc-link capacitor as a function of the switching voltage ripple amplitude are obtained, considering the operating conditions such as the modulation index and the output current amplitude. The calculations are obtained considering the requirements and restrictions referring to the high (switching)-frequency dc-link voltage ripple component. Analyses have been performed considering the dc source impedance (non-ideal dc voltage source at the switching frequency) and a balanced load. Analytical expressions are derived for the dc-link voltage switching ripple amplitude and its maximum value over the fundamental period. Different values of modulation index and output phase angle have been considered and different diagrams are presented. Analytical results were validated both by simulations and comprehensive experimental tests.

11 August 2017 in Energies
Verified
Journal Article
Open access
PDF file
MVMarija Vujacic
Marija Vujacic
MHManel Hammami
Manel Hammami
MSMilan Srndovic
Milan Srndovic
Gabriele GrandiGabriele Grandi
Gabriele Grandi
Direct current (DC)-link voltage ripple analysis is essential for determining harmonic noise and for DC-link capacitor design and selection in single-phase pulse-width modulation (PWM) inverters. This paper provides an extensive theoretical analysis of DC-link voltage ripple for full-bridge (H-bridge) inverters, with simulation and experimental verifications, considering a DC source impedance (non-ideal DC voltage source). The DC voltage ripple amplitude is theoretically estimated as a function of the output current, both amplitude and phase angle, and the modulation index. It consists of a switching frequency component and a double-fundamental frequency component (i.e., 100 Hz), thereby both components are considered in the analysis. In particular, the peak-to-peak distribution, maximum amplitude, and root mean square (RMS) values of the voltage switching ripple over the fundamental period are obtained. Based on the DC voltage requirements, simple and effective guidelines for designing DC-link capacitors are obtained.

30 April 2015 in Energies
Verified
Journal Article
Open access
PDF file
Jelena LoncarskiJelena Loncarski
Jelena Loncarski
MLMats Leijon
Mats Leijon
MSMilan Srndovic
Milan Srndovic
CRClaudio Rossi
Claudio Rossi
Gabriele GrandiGabriele Grandi
Gabriele Grandi
The standard solution for the traction system in battery powered electric vehicles (EVs) is a two-level (2L) inverter feeding a three-phase motor. A simple and effective way to achieve a three-level (3L) inverter in battery-supplied electric vehicles consists of using two standard three-phase 2L inverters with the open-end winding connection of standard three-phase ac motors. The 3L inverter solution can be usefully adopted in EVs since it combines several benefits such as current ripple reduction, increment of phase motor voltage with limited voltage ratings of the two battery banks, improvement in system reliability, etc. The reduction in current ripple amplitude is particularly relevant since it is a source of electromagnetic interference and audio noise from the inverter-motor power connection cables and from the motor itself. By increasing the inverter switching frequency the ripple amplitude is reduced, but the drive efficiency decreases due to the proportionally increased switching losses. In this paper the peak-to-peak ripple amplitude of the dual-2L inverter is evaluated and compared with the corresponding ripple of the single-2L inverter, considering the same voltage and power motor ratings. The ripple analysis is carried out as a function of the modulation index to cover the whole modulation range of the inverter, and the theoretical results are verified with experimental tests carried out by an inverter-motor drive prototype.

12 October 2016 in Energies
Verified
Journal Article
Open access
PDF file
MSMilan Srndovic
Milan Srndovic
YFYakov L. Familiant
Yakov L. Familiant
Gabriele GrandiGabriele Grandi
Gabriele Grandi
ARAlexander Ruderman
Alexander Ruderman
This paper presents the optimization technique for minimizing the voltage and current total harmonic distortion (THD) in a single-phase multilevel inverter controlled by staircase modulation. The previously reported research generally considered the optimal THD problem in the frequency domain, taking into account a limited harmonic number. The novelty of the suggested approach is that voltage and current minimal THD problems are being formulated in the time domain as constrained optimization ones, making it possible to determine the optimal switching angles. In this way, all switching harmonics can be considered. The target function expression becomes very compact and existing efficient solvers for this kind of optimization problems can find a solution in negligible processor time. Current THD is understood as voltage frequency weighted THD that assumes pure inductive load—this approximation is practically accurate for inductively dominant RL-loads. In this study, the optimal switching angles and respective minimal THD values were obtained for different inverter level counts and overall fundamental voltage magnitude (modulation index) dynamic range. Developments are easily modified to cover multilevel inverter grid-connected applications. The results have been verified by experimental tests.

22 January 2019 in Electronics
Verified
Journal Article
Open access
PDF file
MSMilan Srndovic
Milan Srndovic
RFRastko Fišer
Rastko Fišer
Gabriele GrandiGabriele Grandi
Gabriele Grandi
The equivalent inductance of three-phase induction motors is experimentally investigated in this paper, with particular reference to the frequency range from 1 kHz to 20 kHz, typical for the switching frequency in inverter-fed electrical drives. The equivalent inductance is a basic parameter when determining the inverter-motor current distortion introduced by switching modulation, such as rms of current ripple, peak-to-peak current ripple amplitude, total harmonic distortion (THD), and synthesis of the optimal PWM strategy to minimize the THD itself. In case of squirrel-cage rotors, the experimental evidence shows that the equivalent inductance cannot be considered constant in the frequency range up to 20 kHz, and it considerably differs from the value measured at 50 Hz. This frequency-dependent behaviour can be justified mainly by the skin effect in rotor bars affecting the rotor leakage inductance in the considered frequency range. Experimental results are presented for a set of squirrel-cage induction motors with different rated power and one wound-rotor motor in order to emphasize the aforesaid phenomenon. The measurements were carried out by a three-phase sinusoidal generator with the maximum operating frequency of 5 kHz and a voltage source inverter operating in the six-step mode with the frequency up to 20 kHz.