Ion concentration polarization (ICP) is a promising mechanism for concentrating and/or separating charged molecules. This work simulates the extraction of Li+ ions in a diluted high Mg2+/Li+ ratio salt lake brines based on free flow ICP focusing (FF-ICPF). The model solution of diluted brine continuously flows through the system with Li+ slightly concentrated and Mg2+ significantly removed by ICP driven by external pressure and perpendicular electric field. In a typical case, our results showed that this system could focus Li+ concentration by ~1.28 times while decreasing the Mg2+/Li+ ratio by about 85% (from 40 to 5.85). Although Li+ and Mg2+ ions are not separated as an end product, which is preferably required by the lithium industry, this method is capable of decreasing the Mg2+/Li+ ratio significantly and has great potential as a preprocessing technology for lithium extraction from salt lake brines.
Elliptical elements are essential optical surfaces for modifying optical systems. For polishing the whole elliptical surface using doughnut-shaped MCF polishing tool with variable tilt angle, an experimental investigation was conducted in this work. Firstly, a flat workpiece was polished to determine the polishing feasibility. It was found that the middle portion of the polishing tool had optimal ability to remove materials, and the surface roughness Sa at the material removal peak was changed from 134 nm to 17.5 nm within 50 min of polishing. A smoother surface could be obtained using MCF2 slurry and MCF3 slurry, but the use of MCF1 slurry resulted in a rough surface. Then, the effects of working gap h, revolution speed of MCF polishing tool and polishing time on the polishing results were tested to study the polishing characteristics. Sa 9.6 nm and glossiness 278 Gu were obtained, and form error improved from 2.3 μm to 1.3 μm. Finally, the MCF polishing tool was dried to observe the microstructure of the MCF polishing tool after polishing. Abrasive particles were distributed evenly after polishing. It was seen that the abrasive particles were grabbed by the ferric clusters, and the α-celluloses were interleaved between the clusters.
Thrombus is an extremely dangerous factor in the human body that can block the blood vessel. Once thrombus happens in venous of lower limbs, local blood flow is impeded. This leads to varicosity and even pulmonary embolism. In recent years, venous thromboembolism has frequently occurred in a variety of people, and there is no effective treatment for patients with different venous structures. For the patients with venous isomer with venous valve insufficiency, we establish a coupled computational model to simulate the process of thrombolysis with multi-dose treatment schemes by considering the blood as non-Newtonian fluid. And build corresponding in vitro experimental platform for verifying the performance of the developed mathematical model. Then, the effects of different fluid models, valve structures and drug doses on thrombolysis are comprehensively studied through numerical and experimental observations. Comparing with the experimental results, the relative error of blood boosting index (BBI) obtained from non-Newtonian fluid model is 11% times smaller than Newtonian fluid. In addition, the BBI from venous isomer is 13 times stronger than normal patient while the valve displacement is 5 times smaller. As consequence, low eddy current and strong molecular diffusion near the thrombus in case of isomer promote thrombolysis rate up to 18%. Furthermore, the 80 uM dosage of thrombolytic drugs gets the maximum thrombus dissolution rate 18% while the scheme of 50 uM doses obtains a thrombolysis rate of 14% in case of venous isomer. Under the two administration schemes for isomer patients, the rates from experiments are around 19.1% and 14.9%, respectively. It suggests that the proposed computational model and the designed experiment platform can potentially help different patients with venous thromboembolism to carry out clinical medication prediction.