Salvatore Andrea Pullano

Prof. Dr. Salvatore Andrea Pullano

Department of Health Sciences, Magna Graecia University of Catanzaro, Catanzaro, Italy
orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2018 in Sensors and Actuators A: Physical
Verified
Journal Article
Closed access
AFA.S. Fiorillo
A.S. Fiorillo
CCCostantino Davide Critello
Costantino Davide Critello
Salvatore Andrea PullanoSalvatore Andrea Pullano
Salvatore Andrea Pullano

1 January 2022 in Theranostics
Verified
Journal Article
Open access
Salvatore Andrea PullanoSalvatore Andrea Pullano
Salvatore Andrea Pullano
MGMarta Greco
Marta Greco
MBMaria Giovanna Bianco
Maria Giovanna Bianco
DFDaniela Foti
Daniela Foti
Antonio BrunettiAntonio Brunetti
Antonio Brunetti
Antonino S. FiorilloAntonino S. Fiorillo
Antonino S. Fiorillo
The demand of glucose monitoring devices and even of updated guidelines for the management of diabetic patients is dramatically increasing due to the progressive rise in the prevalence of diabetes mellitus and the need to prevent its complications. Even though the introduction of the first glucose sensor occurred decades ago, important advances both from the technological and clinical point of view have contributed to a substantial improvement in quality healthcare. This review aims to bring together purely technological and clinical aspects of interest in the field of glucose devices by proposing a roadmap in glucose monitoring and management of patients with diabetes. Also, it prospects other biological fluids to be examined as further options in diabetes care, and suggests, throughout the technology innovation process, future directions to improve the follow-up, treatment, and clinical outcomes of patients.

20 November 2018 in Sensors
Verified
Journal Article
Open access
PDF file
Salvatore Andrea PullanoSalvatore Andrea Pullano
Salvatore Andrea Pullano
CCCostantino Davide Critello
Costantino Davide Critello
Ifana MahbubIfana Mahbub
Ifana Mahbub
Nishat TasneemNishat Tasneem
Nishat Tasneem
SSSamira Shamsir
Samira Shamsir
Antonino S. FiorilloAntonino S. Fiorillo
Antonino S. Fiorillo
Since the 1970s, a great deal of attention has been paid to the development of semiconductor-based biosensors because of the numerous advantages they offer, including high sensitivity, faster response time, miniaturization, and low-cost manufacturing for quick biospecific analysis with reusable features. Commercial biosensors have become highly desirable in the fields of medicine, food, and environmental monitoring as well as military applications, whereas increasing concerns about food safety and health issues have resulted in the introduction of novel legislative standards for these sensors. Numerous devices have been developed for monitoring biological processes such as nucleic acid hybridization, protein–protein interaction, antigen–antibody bonds, and substrate–enzyme reactions, just to name a few. Since the 1980s, scientific interest moved to the development of semiconductor-based devices, which also include integrated front-end electronics, such as the extended-gate field-effect transistor (EGFET) biosensor, one of the first miniaturized chemical sensors. This work is intended to be a review of the state of the art focused on the development of biosensors and chemosensors based on extended-gate field-effect transistor within the field of bioanalytical applications, which will highlight the most recent research reported in the literature. Moreover, a comparison among the diverse EGFET devices will be presented, giving particular attention to the materials and technologies.

5 June 2017 in PLOS ONE
Verified
Journal Article
Open access
PDF file
FAFrancesca Accattato
Francesca Accattato
MGMarta Greco
Marta Greco
Salvatore Andrea PullanoSalvatore Andrea Pullano
Salvatore Andrea Pullano
ICIlaria Carè
Ilaria Carè
AFAntonino S. Fiorillo
Antonino S. Fiorillo
EGElio Gulletta
Elio Gulletta
Circulating oxidative stress and pro-inflammatory markers change after regular physical exercise; however, how a short session of acute physical activity affects the inflammatory status and redox balance in sedentary individuals is still unclear. Aim of this study is to assess antioxidant and inflammatory parameters, both at rest and after acute exercise, in sedentary young men with or without obesity. Thirty sedentary male volunteers, aged 20–45 (mean age 32 ± 7 years), were recruited, divided into 3 groups (normal weight: BMI < 25 kg/m2; overweight to moderate obesity: 25–35 kg/m2; severe obesity: 35–40 kg/m2), and their blood samples collected before and after a 20-min run at ~ 70% of their VO2max for the measurement of Glutathione Reductase, Glutathione Peroxidase, Superoxide Dismutase, Total Antioxidant Status (TAS) and cytokines (IL-2, IL-4, IL-6, IL-8, IL-10, IL-1α, IL-1β, TNFα, MCP-1, VEGF, IFNγ, EGF). Inter-group comparisons demonstrated significantly higher Glutathione Reductase activity in severely obese subjects in the post-exercise period (P = 0.036), and higher EGF levels in normal weight individuals, either before (P = 0.003) and after exercise (P = 0.05). Intra-group comparisons showed that the acute exercise stress induced a significant increase in Glutathione Reductase activity in severely obese subjects only (P = 0.007), a significant decrease in MCP-1 in the normal weight group (P = 0.02), and a decrease in EGF levels in all groups (normal weight: P = 0.025, overweight/moderate obesity: P = 0.04, severe obesity: P = 0.018). Altogether, these findings suggest that in sedentary individuals with different ranges of BMI, Glutathione Reductase and distinct cytokines are differentially involved into the adaptive metabolic changes and redox responses induced by physical exercise. Therefore, these biomarkers may have the potential to identify individuals at higher risk for developing diseases pathophysiologically linked to oxidative stress.

10 January 2017 in IEEE Sensors Journal
Verified
Journal Article
Closed access
Ifana MahbubIfana Mahbub
Ifana Mahbub
Salvatore Andrea PullanoSalvatore Andrea Pullano
Salvatore Andrea Pullano
HWHanfeng Wang
Hanfeng Wang
SISyed Kamrul Islam
Syed Kamrul Islam
AFAntonino S. Fiorillo
Antonino S. Fiorillo
MMM. R. Mahfouz
M. R. Mahfouz
This paper presents a methodology of monitoring respiration pattern using piezoelectric transducer incorporating CMOS integrated circuits for signal processing and data transmission. As a proof of concept, the system has been tested by placing electrodes on human chest using adhesive hydrogel to detect the pulsatile vibration due to respiration. The system can be used either as a wearable device itself or alternatively can be attached to a jacket or a chest belt. The front-end transducer is a piezoelectric material-based sensor, which is comprised of a ferroelectric polymer named polyvinylidene-fluoride (PVDF). PVDF is also biocompatible, which makes the sensor suitable to be used as a wearable device. The charge produced by the sensor is converted to a proportional voltage signal with the help of a charge amplifier designed in a standard 130-nm CMOS process with eight metal and one poly layer. The analog voltage signal acquired from the charge amplifier is then converted into a digital signal using a reconfigurable pipelined analog-to-digital converter for ease of transmission. An impulse-radio ultra-wideband transmitter operating in the frequency range of 3.1-5 GHz is designed for wireless transmission of the data. The smaller footprint, lighter weight, wireless telemetry, and low-cost material along with the low-power integrated CMOS circuitry for signal processing and data transmission make the proposed system an attractive choice for stable respiration monitoring system.

1 November 2016 in Carbohydrate Polymers
Verified
Journal Article
Closed access
Donato CoscoDonato Cosco
Donato Cosco
PFPaola Failla
Paola Failla
NCNicola Costa
Nicola Costa
Salvatore Andrea PullanoSalvatore Andrea Pullano
Salvatore Andrea Pullano
AFAntonino Fiorillo
Antonino Fiorillo
Donatella PaolinoDonatella Paolino
Donatella Paolino