Accurate source location is a critical component of microseismic monitoring and early warning systems. To improve the accuracy of microseismic source location, this manuscript proposes a GA-PSO algorithm that combines the Genetic Algorithm (GA) with Particle Swarm Optimization (PSO). The GA-PSO algorithm enhances the PSO algorithm by dynamically adjusting the balance between global exploration and local exploitation through a sinusoidal function for the nonlinear adjustment of both learning factors, and an adaptive inertia weight that decreases quadratically with iterations. Additionally, the precision of the solutions is further improved through the crossover and mutation operations of the GA. In the simulated location model, the GA-PSO algorithm demonstrated the smallest error value, outperforming both the GA and PSO algorithm in terms of accuracy. Furthermore, the GA-PSO algorithm exhibited minimal sensitivity to wave speed fluctuations of ±1%, ±3%, and ±5%, maintaining the error within 0.5 m. The validation through the blasting experiment at the Shizhuyuan mine further confirmed the enhanced accuracy of the GA-PSO algorithm, with a location error of 20.08 m, representing an improvement of 59% over the GA and 43% over the PSO algorithm.
31 December 2017 in Journal of Measurements in Engineering
The subject of the studies presented in this paper is the fabrication of electrochemical geophone, especially the electrochemical transducer with symmetrical four-electrode cell by FPCB process technology. The geophone assembled by transducer, dumbbell-shaped tube, highly-flexible membranes, electrolyte solution and signal-amplification circuit, is calibrated using a standard vibration platform, and the results show a good consistency of each geophone parameters. Coupled with low cost, the electrochemical geophone by FPCB shows a good potential application prospect.
Based on the dynamic force feedback network, a fast self-adjusting method with field working ability is designed for the electrochemical seismometer. Dynamic feedback network provides the characteristics of adaptability in complex environments for the seismometer. And the reusage of feedback source provides a very low-cost self-testing ability without a laboratory environment or any external equipment. To implement this method, an analytical adjusting algorithm is derived. The simulation shows the adjusting adaptability for arbitrary targets and multiple electrochemical seismometers. A prototype is developed to verify the method, the prototype can be adjusted to the optimal second-order system under arbitrarily cutoff frequency between 0.5Hz and 1Hz, and the self-adjusting process finished within 10 minutes.
25 February 2022 in IEEE Transactions on Instrumentation and Measurement
Seismic node is an important geological exploration equipment. The seismic node has a complex near-ground application environment. The near-ground seriously interferes with the wireless signal of the seismic node and affects its data transmission capability. This article proposes a link and energy-aware gradient routing (LEGR) method, which can effectively reduce the interference of the near-ground on the seismic node. LEGR introduces the concept of link potential energy (LPE) to represent the gradient and establishes the LPE loss model using the link quality and the remaining power. The LPE is generated by the data acquisition center (DAC) and spreads to each node with some loss which is depending on the LPE loss model during the propagation process, and finally, a gradient field about the LPE is formed. Data are transmitted along the steepest direction of the gradient to the DAC. The simulation results show that LEGR significantly reduces the impact of wireless signal strength fluctuations on the seismic node compared with other traditional routing methods. The experimental results show that LEGR is superior to the commonly used routing method for seismic nodes network in term of packets latency and packet delivery rate, improves the anti-interference ability, and enhances the wireless communication reliability for the seismic node networks.
We propose a novel liquid jet gyroscope based on electrochemical transducers, which uses electrolyte as the jet medium, and two electrochemical transducers placed symmetrically as the velocity measuring unit. The gyroscope includes a fluid pump to generate a jet flow, which flows into the jet chamber. Then, it is diverged into the shunt channels, pumped into reflux channels and merged by a fluid pump. The velocities of shunt flows are measured by two electrochemical transducers. The feasibility of the method was demonstrated in theory, and a 2D finite element model was built to simulate the dynamics of the liquid jet gyroscope. Simulation results confirm the effectiveness of the gyroscope, which has higher sensitivity in the near DC frequency band.
Hydrophone is a key component of marine seismic exploration systems, divided into a scalar hydrophone and vector hydrophone. The electrochemical vector hydrophone has attracted much attention due to its high sensitivity and low-frequency detection capability. With the development of noise reduction technology, high-frequency noise has been effectively suppressed, while low-frequency noise is still difficult to control, which has become a key issue in the monitoring of underwater target radiation noise. The traditional electrochemical vector hydrophone based on the molecular electron transfer (MET) principle is limited in the working bandwidth in the low-frequency band, which affects the detection capability of low-frequency radiation signals from underwater targets. In order to solve this problem, a frequency response extension method of a MET electrochemical vector hydrophone based on dynamic feedback network is proposed. By introducing a dynamic force balance negative feedback system based on a digital signal processor (DSP), the working bandwidth of the hydrophone is extended, and the detection capability of low-frequency signals is enhanced. At the same time, the system has field adjustability and can resist the long-term system frequency characteristic drift. Experimental results show that the proposed method effectively improves the frequency response performance of the electrochemical vector hydrophone, providing a new technical solution for its application in the monitoring of low-frequency radiation noise from underwater targets.