Microscale uncertainties related to the geometry and morphology of polycrystalline silicon films, constituting the movable structures of micro electro-mechanical systems (MEMS), were investigated through a joint numerical/experimental approach. An on-chip testing device was designed and fabricated to deform a compliant polysilicon beam. In previous studies, we showed that the scattering in the input–output characteristics of the device can be properly described only if statistical features related to the morphology of the columnar polysilicon film and to the etching process adopted to release the movable structure are taken into account. In this work, a high fidelity finite element model of the device was used to feed a transitional Markov chain Monte Carlo (TMCMC) algorithm for the estimation of the unknown parameters governing the aforementioned statistical features. To reduce the computational cost of the stochastic analysis, a synergy of proper orthogonal decomposition (POD) and kriging interpolation was adopted. Results are reported for a batch of nominally identical tested devices, in terms of measurement error-affected probability distributions of the overall Young’s modulus of the polysilicon film and of the overetch depth.
When the dimensions of polycrystalline structures become comparable to the average grain size, some reliability issues can be reported for the moving parts of inertial microelectromechanical systems (MEMS). Not only the overall behavior of the device turns out to be affected by a large scattering, but also the sensitivity to imperfections gets enhanced. In this work, through on-chip tests, we experimentally investigate the behavior of thin polysilicon samples using standard electrostatic actuation/sensing. The discrepancy between the target and actual responses of each sample has then been exploited to identify: (i) the overall stiffness of the film and, according to standard continuum elasticity, a morphology-based value of its Young’s modulus; (ii) the relevant over-etch induced by the fabrication process. To properly account for the aforementioned stochastic features at the micro-scale, the identification procedure has been based on particle filtering. A simple analytical reduced-order model of the moving structure has been also developed to account for the nonlinearities in the electrical field, up to pull-in. Results are reported for a set of ten film samples of constant slenderness, and the effects of different actuation mechanisms on the identified micromechanical features are thoroughly discussed.
In this paper, we investigate the stochastic effects of the microstructure of polysilicon films on the overall response of microelectromechanical systems (MEMS). A device for on-chip testing has been purposely designed so as to maximize, in compliance with the production process, its sensitivity to fluctuations of the microstructural properties; as a side effect, its sensitivity to geometrical imperfections linked to the etching process has also been enhanced. A reduced-order, coupled electromechanical model of the device is developed and an identification procedure, based on a genetic algorithm, is finally adopted to tune the parameters ruling microstructural and geometrical uncertainties. Besides an initial geometrical imperfection that can be considered specimen-dependent due to its scattering, the proposed procedure has allowed identifying an average value of the effective polysilicon Young’s modulus amounting to 140 GPa, and of the over-etch depth with respect to the target geometry layout amounting to m. The procedure has been therefore shown to be able to assess how the studied stochastic effects are linked to the scattering of the measured input–output transfer function of the device under standard working conditions. With a continuous trend in miniaturization induced by the mass production of MEMS, this study can provide information on how to handle the foreseen growth of such scattering.
In this work, we provide a numerical/experimental investigation of the micromechanics-induced scattered response of a polysilicon on-chip MEMS testing device, whose moving structure is constituted by a slender cantilever supporting a massive perforated plate. The geometry of the cantilever was specifically designed to emphasize the micromechanical effects, in compliance with the process constraints. To assess the effects of the variability of polysilicon morphology and of geometrical imperfections on the experimentally observed nonlinear sensor response, we adopt statistical Monte Carlo analyses resting on a coupled electromechanical finite element model of the device. For each analysis, the polysilicon morphology was digitally built through a Voronoi tessellation of the moving structure, whose geometry was in turn varied by sampling out of a uniform probability density function the value of the over-etch, considered as the main source of geometrical imperfections. The comparison between the statistics of numerical and experimental results is adopted to assess the relative significance of the uncertainties linked to variations in the micro-fabrication process, and the mechanical film properties due to the polysilicon morphology.
Fluid damping is studied for resonant torsional micromirrors, electrostatically actuated by comb fingers. A three-dimensional computational fluid dynamics (CFD) model of the air flow around the moving parts of the mirror is developed, coping with dynamic remeshing procedures to properly account for the large displacement setting required by the motion of the compliant structure. The time evolution of the damping torque contributions, due to shear at comb fingers and to drag over the surfaces of the micromirror plate, are computed. The relevant numerical estimation of the overall quality factor of the system is shown to compare well with available experimental results.
Microelectromechanical systems (MEMS) have been already successfully commercialized for around 20 years. The design of novel MEMS sensors currently targets two important features: smaller dimensions and higher reliability. As the characteristic size of the mechanical components of the devices decreases, uncertainties in the mechanical and geometrical properties induced by the microfabrication process become more and more important. To address these issues, an on-chip testing device has been proposed to avoid any visual inspection for the read-out. The electromechanical responses of ten nominally identical specimens have been recorded, and experimental data have shown a significant scattering due to the presence of relevant uncertainty sources. To interpret the response of the device, an analytical reduced-order model of the whole device has been developed. A genetic algorithm has then been adopted to identify features of the mechanical and geometrical uncertainties in the batch of test structures.