Duy Duong Nguyen

Dr. Duy Duong Nguyen

orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2010 in Phonetica
Verified
Journal Article
Closed access
PDF file
MBMarc Brunelle
Marc Brunelle
DNDuy Duong Nguyen
Duy Duong Nguyen
KNKhac Hùng Nguyên
Khac Hùng Nguyên
A laryngographic and laryngoscopic study of tone production in Northern Vietnamese, a language whose tones combine both fundamental frequency (f0) modulations and voice qualities (phonation types), was conducted with 5 male and 5 female speakers. Results show that the f0 contours of Northern Vietnamese tones are not only attributable to changes in vocal fold length and tension (partly through changes in larynx height), but that f0 drops are also largely caused by the glottal configurations responsible for the contrastive voice qualities associated with some of the tones. We also find that voice quality contrasts are mostly due to glottal constriction: they occasionally involve additional ventricular fold incursion and epiglottal constriction, but these articulations are usually absent.

1 March 2009 in Journal of Voice
Verified
Journal Article
Closed access
DNDuy Duong Nguyen
Duy Duong Nguyen
Dianna Theadora KennyDianna Theadora Kenny
Dianna Theadora Kenny
NTNinh Duy Tran
Ninh Duy Tran
JLJonathan R. Livesey
Jonathan R. Livesey

24 February 2024 in BMJ Open
Verified
Journal Article
Open access
PDF file
RGRijul Gupta
Rijul Gupta
DGDhanshree R Gunjawate
Dhanshree R Gunjawate
DNDuy Duong Nguyen
Duy Duong Nguyen
CJCraig Jin
Craig Jin
CMCatherine Madill
Catherine Madill
Introduction Over the past decade, several machine learning (ML) algorithms have been investigated to assess their efficacy in detecting voice disorders. Literature indicates that ML algorithms can detect voice disorders with high accuracy. This suggests that ML has the potential to assist clinicians in the analysis and treatment outcome evaluation of voice disorders. However, despite numerous research studies, none of the algorithms have been sufficiently reliable to be used in clinical settings. Through this review, we aim to identify critical issues that have inhibited the use of ML algorithms in clinical settings by identifying standard audio tasks, acoustic features, processing algorithms and environmental factors that affect the efficacy of those algorithms. Methods We will search the following databases: Web of Science, Scopus, Compendex, CINAHL, Medline, IEEE Explore and Embase. Our search strategy has been developed with the assistance of the university library staff to accommodate the different syntactical requirements. The literature search will include the period between 2013 and 2023, and will be confined to articles published in English. We will exclude editorials, ongoing studies and working papers. The selection, extraction and analysis of the search data will be conducted using the ‘Preferred Reporting Items for Systematic Reviews and Meta-Analyses extension for scoping reviews’ system. The same system will also be used for the synthesis of the results. Ethics and dissemination This scoping review does not require ethics approval as the review solely consists of peer-reviewed publications. The findings will be presented in peer-reviewed publications related to voice pathology.

25 December 2018 in The Laryngoscope
Verified
Journal Article
Open access
PDF file
CMCatherine Madill
Catherine Madill
DNDuy Duong Nguyen
Duy Duong Nguyen
KCKristie Yick‐Ning Cham
Kristie Yick‐Ning Cham
DNDaniel Novakovic
Daniel Novakovic
PMPatricia McCabe
Patricia McCabe
Objectives/Hypothesis: Cepstral peak prominence (CPP) has been reported as a reliable measure of dysphonia and a preferred alternative to harmonics‐to‐noise ratio (HNR). However, CPP has been observed to be sensitive to articulatory variation and vocal intensity. The aim of this study was to examine the impact of nasalance on CPP and HNR of voice signals. It was hypothesized that increased nasalance would be associated with decreased CPP.Study Design: Within‐subject correlation design.Methods: Thirty vocally healthy female participants were recorded reading and producing a vowel in alternation with a nasal consonant while wearing a nasometer for calculation of nasalance. Recorded vowel, nasalized, and nasal segments of speech were used to calculate CPP using Analysis of Dysphonia in Speech and Voice software, and HNR and vocal intensity using Praat software.Results: Significant main effects of conditions were observed for CPP. CPP values decreased significantly when phonation changed from vowel to nasalized vowel and to nasal. There was correlation between CPP and nasalance and between CPP and intensity. HNR was slightly higher in the nasal condition than in vowel. There was a weak correlation between HNR and nasalance. No correlation was found between HNR and intensity.Conclusions: CPP is sensitive to changes in vocal tract configuration caused by nasalization as well as intensity, whereas HNR is not. Therefore, CPP may reflect the periodicity in source signal or the filtering effects of vocal tract. Further research is needed to clarify the application and interpretation of CPP in clinical practice.Level of Evidence: 4Laryngoscope, 129:E299–E304, 2019

18 January 2021 in The Laryngoscope
Verified
Journal Article
Open access
PDF file
DNDuy Duong Nguyen
Duy Duong Nguyen
JPJing‐Yin Pang
Jing‐Yin Pang
CMCatherine Madill
Catherine Madill
DNDaniel Novakovic
Daniel Novakovic
Objective: Previous research has shown that effective application of angiolytic lasers in microlaryngeal surgery is determined by wavelength, pulse width (PW), and fluence. Recently, a 445‐nm (blue) laser (BL) has been developed with a potentially greater hemoglobin absorption than previous lasers. The chick chorioallantoic membrane (CAM) represents a suitable model for testing various settings to find out the most optimal settings of this laser. This study used the CAM model to examine whether successful photoangiolytic effects could be obtained using BL.Methods: Seven hundred and ninety three third‐order vascular segments of viable CAM were irradiated using BL via 400‐μm diameter fiber, 1 pulse/second, with PW and power varied systematically at standardized fiber‐to‐vessel distances of 1 and 3 mm. Outcome measures including vessel ablation rate (AR), rupture rate (RR), and visible tissue effects were analyzed using Chi‐square test.Results: Energy levels of 400, 540, and 600 mJ (per pulse) were most effective for vessel ablation. A working distance of 3 mm resulted in higher ablation and less vessel rupture compared with 1 mm at these optimal energy levels. At 3 mm, a longer PW resulted in higher AR. At 1 mm, AR increased with shorter PW and higher power. The 1‐mm working distance resulted in lower tissue effects than 3 mm.Conclusion: Findings in this study showed that BL was effective in vessel ablation using relevant combination of working distance, PW, and energy levels. To obtain high AR, longer working distance plus longer PW was required and if working distance was reduced, shorter PW should be set.Level of Evidence: NA Laryngoscope, 131:E1950–E1956, 2021

15 February 2022 in International Journal of Language & Communication Disorders
Verified
Journal Article
Open access
PDF file
DNDuy Duong Nguyen
Duy Duong Nguyen
ACAntonia Margarita Chacon
Antonia Margarita Chacon
CPChristopher Payten
Christopher Payten
RBRebecca Black
Rebecca Black
Meet Chetan ShethMeet Chetan Sheth
Meet Chetan Sheth
CMCatherine Madill
Catherine Madill
Background: Previous research has found that high‐frequency energy of speech signals decreased while wearing face masks. However, no study has examined the specific spectral characteristics of fricative consonants and vowels and the perception of clarity of speech in mask wearing.Aims: To investigate acoustic–phonetic characteristics of fricative consonants and vowels and auditory perceptual rating of clarity of speech produced with and without wearing a face mask.Methods & Procedures: A total of 16 healthcare workers read the Rainbow Passage using modal phonation in three conditions: without a face mask, with a standard surgical mask and with a KN95 mask (China GB2626‐2006, a medical respirator with higher barrier level than the standard surgical mask). Speech samples were acoustically analysed for root mean square (RMS) amplitude (ARMS) and spectral moments of four fricatives /f/, /s/, /ʃ/ and /z/; and amplitude of the first three formants (A1, A2 and A3) measured from the reading passage and extracted vowels. Auditory perception of speech clarity was performed. Data were compared across mask and non‐mask conditions using linear mixed models.Outcomes & Results: The ARMS of all included fricatives was significantly lower in surgical mask and KN95 mask compared with non‐mask condition. Centre of gravity of /f/ decreased in both surgical and KN95 mask while other spectral moments did not show systematic significant linear trends across mask conditions. None of the formant amplitude measures was statistically different across conditions. Speech clarity was significantly poorer in both surgical and KN95 mask conditions.Conclusions & Implications: Speech produced while wearing either a surgical mask or KN95 mask was associated with decreased fricative amplitude and poorer speech clarity.WHAT THIS PAPER ADDS: What is already known on the subject: Previous studies have shown that the overall spectral levels in high frequency ranges and intelligibility are decreased for speech produced with a face mask. It is unclear how different types of the speech signals that is, fricatives and vowels are presented in speech produced with wearing either a medical surgical or KN95 mask. It is also unclear whether ratings of speech clarity are similar for speech produced with these face masks. What this paper adds to existing knowledge: Speech data collected using a real‐world, clinical and non‐laboratory‐controlled settings showed differences in the amplitude of fricatives and speech clarity ratings between non‐mask and mask‐wearing conditions. Formant amplitude did not show significant differences in mask‐wearing conditions compared with non‐mask. What are the potential or actual clinical implications of this work?: Wearing a surgical mask or a KN95 mask had different effects on consonants and vowels. It appeared from the findings in this study that these masks only affected fricative consonants and did not affect vowel production. The poorer speech clarity in these mask‐wearing conditions has important implications for speech perception in communication between clinical staff and between medical officers and patients in clinics, and between people in everyday situations. The impact of these masks on speech perception may be more pronounced in people with hearing impairment and communication disorders. In voice evaluation and/or therapy sessions, the effects of wearing a medical mask can occur bidirectionally for both the clinician and the patient. The patient may find it more challenging to understand the speech conveyed by the clinician while the clinician may not perceptually assess patient's speech and voice accurately. Given the significant correlation between clarity ratings and fricative amplitude, improving fricative signals would be useful to improve speech clarity while wearing these medical face masks.