Craig Jin

Craig Jin

Auto-generated profile, based on publicly available information

Craig Jin

The University of Sydney

Research Focus & Metrics

Academic Career Length

40Years (1987-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 November 2019 in Frontiers in Bioengineering and Biotechnology
Verified
Journal Article
Open access
PDF file
PTPriyanka Tharkar
Priyanka Tharkar
RVRamya Varanasi
Ramya Varanasi
WWWu Shun Felix Wong
Wu Shun Felix Wong
CJCraig T. Jin
Craig T. Jin
Wojciech ChrzanowskiWojciech Chrzanowski
Wojciech Chrzanowski
While ultrasound is most widely known for its use in diagnostic imaging, the energy carried by ultrasound waves can be utilized to influence cell function and drug delivery. Consequently, our ability to use ultrasound energy at a given intensity unlocks the opportunity to use the ultrasound for therapeutic applications. Indeed, in the last decade ultrasound-based therapies have emerged with promising treatment modalities for several medical conditions. More recently, ultrasound in combination with nanomedicines, i.e., nanoparticles, has been shown to have substantial potential to enhance the efficacy of many treatments including cancer, Alzheimer disease or osteoarthritis. The concept of ultrasound combined with drug delivery is still in its infancy and more research is needed to unfold the mechanisms and interactions of ultrasound with different nanoparticles types and with various cell types. Here we present the state-of-art in ultrasound and ultrasound-assisted drug delivery with a particular focus on cancer treatments. Notably, this review discusses the application of high intensity focus ultrasound for non-invasive tumor ablation and immunomodulatory effects of ultrasound, as well as the efficacy of nanoparticle-enhanced ultrasound therapies for different medical conditions. Furthermore, this review presents safety considerations related to ultrasound technology and gives recommendations in the context of system design and operation.

1 May 2010 in Clinical Neurophysiology
Verified
Journal Article
Closed access
GGGaetano Gargiulo
Gaetano Gargiulo
RCRafael A. Calvo
Rafael A. Calvo
PBPaolo Bifulco
Paolo Bifulco
Mario CesarelliMario Cesarelli
Mario Cesarelli
CJCraig Jin
Craig Jin
ASAndre van Schaik
Andre van Schaik

1 July 2005 in The Journal of the Acoustical Society of America
Verified
Journal Article
Closed access
PDF file
VBVirginia Best
Virginia Best
SCSimon Carlile
Simon Carlile
CJCraig Jin
Craig Jin
ASAndre van Schaik
Andre van Schaik
This study measured the accuracy with which human listeners can localize spoken words. A broadband (300Hz–16kHz) corpus of monosyllabic words was created and presented to listeners using a virtual auditory environment. Localization was examined for 76 locations on a sphere surrounding the listener. Experiment 1 showed that low-pass filtering the speech sounds at 8kHz degraded performance, causing an increase in polar angle errors associated with the cone of confusion. In experiment 2 it was found that performance in fact varied systematically with the level of the signal above 8kHz . Although the lower frequencies (below 8kHz ) are known to be sufficient for accurate speech recognition in most situations, these results demonstrate that natural speech contains information between 8 and 16kHz that is essential for accurate localization.

24 April 2012 in Physiological Measurement
Verified
Journal Article
Closed access
DND T Nguyen
D T Nguyen
CJC Jin
C Jin
ATA Thiagalingam
A Thiagalingam
Alistair McEwanAlistair McEwan
Alistair McEwan
Although electrical impedance tomography (EIT) for ventilation monitoring is on the verge of clinical trials, pulmonary perfusion imaging with EIT remains a challenge, especially in spontaneously breathing subjects. In anticipation of more research on this subject, we believe a thorough review is called for. In this paper, findings related to the physiological origins and electrical characteristics of this signal are summarized, highlighting properties that are particularly relevant to EIT. The perfusion impedance change signal is significantly smaller in amplitude compared with the changes due to ventilation. Therefore, the hardware used for this purpose must be more sensitive and more resilient to noise. In previous works, some signal- or image-processing methods have been required to separate these two signals. Three different techniques are reviewed in this paper, including the ECG-gating method, frequency-domain-filtering-based methods and a principal-component-analysis-based method. In addition, we review a number of experimental studies on both human and animal subjects that employed EIT for perfusion imaging, with promising results in the diagnosis of pulmonary embolism (PE) and pulmonary arterial hypertension as well as other potential applications. In our opinion, PE is most likely to become the main focus for perfusion EIT in the future, especially for heavily instrumented patients in the intensive care unit (ICU).

1 March 2012 in Applied Mathematical Modelling
Verified
Journal Article
Closed access
JTJ. Nasehi Tehrani
J. Nasehi Tehrani
Alistair McEwanAlistair McEwan
Alistair McEwan
CJC. Jin
C. Jin
ASAndre van Schaik
Andre van Schaik

15 April 2008 in IEEE Transactions on Biomedical Circuits and Systems
Verified
Journal Article
Closed access
Tara HamiltonTara Hamilton
Tara Hamilton
CJCraig Jin
Craig Jin
ASAndre van Schaik
Andre van Schaik
JTJohnathon Tapson
Johnathon Tapson
In this paper, we present an analog integrated circuit design for an active 2-D cochlea and measurement results from a fabricated chip. The design includes a quality factor control loop that incorporates some of the nonlinear behavior exhibited in the real cochlea. This control loop varies the gain and the frequency selectivity of each cochlear resonator based on the amplitude of the input signal.