The technology of 3D printing, particularly fused deposition modeling (FDM) 3D printing, has revolutionized the development of electrochemical biosensors, offering a versatile and cost-effective approach for clinical applications. This review explores the integration of FDM in fabricating biosensing platforms tailored for clinical diagnostics, emphasizing its role in detecting various biomarkers and viral pathogens. Advances in 3D printing materials, especially the emergence of bespoke conductive filaments, have allowed the production of highly customizable and efficient biosensors. A detailed discussion focuses on the design and application of these biosensors for viral detection, highlighting their potential to improve diagnostic accuracy. Furthermore, the review addresses current trends, including the push towards miniaturization and multianalyte detection, alongside challenges such as material optimization and regulatory hurdles. By providing a comprehensive overview, this work underscores the transformative impact of 3D-printed electrochemical biosensors in clinical diagnostics while also identifying critical areas for future research and development.
6 August 2021 in Monatshefte für Chemie - Chemical Monthly
During the severe acute respiratory syndrome coronavirus (SARS-CoV-2) pandemic, ivermectin (IVM), a broad-spectrum antiparasitic drug, was one of the medications prescribed to manage symptoms. However, its effectiveness against the virus has not been conclusively demonstrated. The increased consumption of IVM raised environmental and health concerns, including bioaccumulation and microbial resistance. To address these issues, electroanalytical methods have been explored for IVM detection, offering advantages such as low cost, portability, and high sensitivity. Super-P carbon black (SPCB) is a conductive nanomaterial used to modify glassy carbon electrodes, enhancing electrochemical performance. In this work, electrochemical sensors based on SPCB were developed using the drop-casting technique for IVM sensing. Through studies using cyclic voltammetry (CV), it was determined that the mass transport for the glassy carbon electrode modified with Super-P carbon black (SPCB/GCE) is governed by the adsorption of the species. After parameter optimization for differential pulse voltammetry technique, the sensor exhibited a linear working range of 10-100 µmol L−1, a limit of detection (LOD) of 1.3 µmol L−1 , a limit of quantification (LOQ) of 4.2 µmol L−1, and a sensitivity of 0.101 µA µmol L−1 . The developed method was applied to analysis of pharmaceutical tablets, tap water, and synthetic urine.