Luiz Ricardo G. Silva

Luiz Ricardo G. Silva

Auto-generated profile, based on publicly available information

Luiz Ricardo G. Silva

UNIVERSIDADE FEDERAL DO MARANHÃO

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 December 2024 in Electrochimica Acta
Verified
Journal Article
Closed access
LSLuiz R.G. Silva
Luiz R.G. Silva
LBLucas Ventosa Bertolim
Lucas Ventosa Bertolim
JSJessica Santos Stefano
Jessica Santos Stefano
JBJuliano A. Bonacin
Juliano A. Bonacin
EREduardo M. Richter
Eduardo M. Richter
BJBruno C. Janegitz
Bruno C. Janegitz

29 September 2024 in Microchimica Acta
Verified
Journal Article
Closed access
PDF file
MSMichele V. C. O. Silva
Michele V. C. O. Silva
MCMayane S. Carvalho
Mayane S. Carvalho
LSLuiz R. G. Silva
Luiz R. G. Silva
RRRaquel G. Rocha
Raquel G. Rocha
LCLuciana V. Cambraia
Luciana V. Cambraia
JSJessica Santos Stefano
Jessica Santos Stefano

1 January 2025 in Electrochimica Acta
Verified
Journal Article
Closed access
LSLuiz Ricardo G. Silva
Luiz Ricardo G. Silva
RRRaquel G. Rocha
Raquel G. Rocha
DRDiego P. Rocha
Diego P. Rocha
ENEdson Nossol
Edson Nossol
BJBruno C. Janegitz
Bruno C. Janegitz
JSJessica Santos Stefano
Jessica Santos Stefano

8 February 2024 in Materials Chemistry and Physics
Verified
Journal Article
Closed access
BSBruna S. de Sá
Bruna S. de Sá
JSJessica Santos Stefano
Jessica Santos Stefano
LSLuiz Ricardo G. e Silva
Luiz Ricardo G. e Silva
TPTarcísio M. Perfecto
Tarcísio M. Perfecto
TMTalita Mazon
Talita Mazon
Caue RibeiroCaue Ribeiro
Caue Ribeiro

4 May 2026 in Brazilian Journal of Analytical Chemistry
Verified
Journal Article
Closed access
MFMylla Fróz
Mylla Fróz
DFDianderson Ferreira
Dianderson Ferreira
MGMatheus Garcez
Matheus Garcez
GDGustavo Diniz
Gustavo Diniz
LSLuiz Silva
Luiz Silva
LDLUIZA MARIA FERREIRA DANTAS
LUIZA MARIA FERREIRA DANTAS
Nimesulide (NMS) is a sulfonamide-class non-steroidal anti-inflammatory drug widely used in pharmaceutical formulations, whose reliable quantification is essential for quality control. In this work, an unmodified laser-induced graphene electrode (LIGe), fabricated by direct CO2 laser ablation of polyimide, is proposed for the electrochemical determination of NMS using square-wave voltammetry (SWV). Voltammetric studies revealed that NMS oxidation is an irreversible, diffusion-controlled process that involves the transfer of two protons and two electrons. After systematic optimization of pH and instrumental parameters, the method exhibited a wide linear working range from 11.0 to 131 µmol L-1, with a detection limit of 1.30 µmol L-1. The sensor showed good repeatability (RSD < 5%, n = 10) and was successfully applied to the analysis of pharmaceutical tablets, yielding results consistent with the declared content. Accuracy was further evaluated in synthetic urine, with recovery rates between 97% and 111%. Interference studies demonstrated that common non-electroactive urinary constituents caused only minor signal variations (<3%). Although the detection limit is higher than that reported for heavily modified electrodes, the proposed approach offers simplicity of fabrication, rapid analysis, disposability, and a broad linear range, which are notably advantageous for pharmaceutical quality control applications where analyte concentrations are relatively high. These results highlight unmodified LIG as a practical, cost-effective, and scalable sensing platform for routine nimesulide analysis.

1 January 2026 in Journal of the Brazilian Chemical Society
Verified
Journal Article
Closed access
DFDianderson Cristiano M. Ferreira
Dianderson Cristiano M. Ferreira
DSDomingos R. Santos-Neto
Domingos R. Santos-Neto
CLCarlos Eduardo C. Lopes
Carlos Eduardo C. Lopes
RPRebeca B. Praseres
Rebeca B. Praseres
LSLuiz Ricardo G. e Silva
Luiz Ricardo G. e Silva
ISIranaldo S. da Silva
Iranaldo S. da Silva
During the severe acute respiratory syndrome coronavirus (SARS-CoV-2) pandemic, ivermectin (IVM), a broad-spectrum antiparasitic drug, was one of the medications prescribed to manage symptoms. However, its effectiveness against the virus has not been conclusively demonstrated. The increased consumption of IVM raised environmental and health concerns, including bioaccumulation and microbial resistance. To address these issues, electroanalytical methods have been explored for IVM detection, offering advantages such as low cost, portability, and high sensitivity. Super-P carbon black (SPCB) is a conductive nanomaterial used to modify glassy carbon electrodes, enhancing electrochemical performance. In this work, electrochemical sensors based on SPCB were developed using the drop-casting technique for IVM sensing. Through studies using cyclic voltammetry (CV), it was determined that the mass transport for the glassy carbon electrode modified with Super-P carbon black (SPCB/GCE) is governed by the adsorption of the species. After parameter optimization for differential pulse voltammetry technique, the sensor exhibited a linear working range of 10-100 µmol L−1, a limit of detection (LOD) of 1.3 µmol L−1 , a limit of quantification (LOQ) of 4.2 µmol L−1, and a sensitivity of 0.101 µA µmol L−1 . The developed method was applied to analysis of pharmaceutical tablets, tap water, and synthetic urine.