Mohammad Iman Mokhlespour Esfahani

Dr. Mohammad Iman Mokhlespour Esfahani

Department of Mechanical Engineering, The University of Michigan, Ann Arbor, MI 48105, USA
orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2018 in Applied Ergonomics
Verified
Journal Article
Closed access
SKSunwook Kim
Sunwook Kim
MNMaury Nussbaum
Maury Nussbaum
Mohammad Iman Mokhlespour EsfahaniMohammad Iman Mokhlespour Esfahani
Mohammad Iman Mokhlespour Esfahani
MAMohammad Mehdi Alemi
Mohammad Mehdi Alemi
SASaad Alabdulkarim
Saad Alabdulkarim
EREhsan Rashedi
Ehsan Rashedi

1 July 2018 in Applied Ergonomics
Verified
Journal Article
Closed access
SKSunwook Kim
Sunwook Kim
MNMaury Nussbaum
Maury Nussbaum
Mohammad Iman Mokhlespour EsfahaniMohammad Iman Mokhlespour Esfahani
Mohammad Iman Mokhlespour Esfahani
MAMohammad Mehdi Alemi
Mohammad Mehdi Alemi
BJBochen Jia
Bochen Jia
EREhsan Rashedi
Ehsan Rashedi

25 July 2018 in IEEE Sensors Journal
Verified
Journal Article
Closed access
Mohammad Iman Mokhlespour EsfahaniMohammad Iman Mokhlespour Esfahani
Mohammad Iman Mokhlespour Esfahani
MNMaury Nussbaum
Maury Nussbaum
The use of interactive or “smart” textiles that have sensing material(s) incorporated into them supports an emerging technology for physical activity assessment called smart textile systems (STSs). STSs are an increasingly useful technology for researchers, athletes, patients, and others. In this paper, we developed and assessed a novel smart undershirt (SUS) that was designed to monitor low-back (thorax versus pelvis) and shoulder motions. The SUS consists of stretchable undershirt, electronic components, and an array of 11 body-worn sensors (BWSs) printed on the clothing. The BWSs are developed by coating electroactive polymers (i.e., polymerization) on the fabric and are wired using conductive threads. This shirt is the first smart garment for tracking both lower back and shoulder motions using printed textile sensors. The 16 participants performed 10 upper body movements while wearing the SUS for the purpose of assessing the accuracy of task classification and angle estimation. Input from the SUS led to classification accuracy at the individual levels up to 94% and planar angle estimations with errors on the order of 1.3° and 9.4° for the low back and shoulder, respectively. The performance was poorer, though, at the group level. The SUS appears to be a promising alternative for the purpose of monitoring upper body motions and activities.

1 August 2018 in Sensors
Verified
Journal Article
Open access
PDF file
Mohammad Iman Mokhlespour EsfahaniMohammad Iman Mokhlespour Esfahani
Mohammad Iman Mokhlespour Esfahani
MNMaury Nussbaum
Maury Nussbaum
Wearable sensors and systems have become increasingly popular in recent years. Two prominent wearable technologies for human activity monitoring are smart textile systems (STSs) and inertial measurement units (IMUs). Despite ongoing advances in both, the usability aspects of these devices require further investigation, especially to facilitate future use. In this study, 18 participants evaluate the preferred placement and usability of two STSs, along with a comparison to a commercial IMU system. These evaluations are completed after participants engaged in a range of activities (e.g., sitting, standing, walking, and running), during which they wear two representatives of smart textile systems: (1) a custom smart undershirt (SUS) and commercial smart socks; and (2) a commercial whole-body IMU system. We first analyze responses regarding the usability of the STS, and subsequently compared these results to those for the IMU system. Participants identify a short-sleeved shirt as their preferred activity monitor. In additional, the SUS in combination with the smart socks is rated superior to the IMU system in several aspects of usability. As reported herein, STSs show promise for future applications in human activity monitoring in terms of usability.

8 January 2017 in Sensors
Verified
Journal Article
Open access
PDF file
Mohammad Iman Mokhlespour EsfahaniMohammad Iman Mokhlespour Esfahani
Mohammad Iman Mokhlespour Esfahani
OZOmid Zobeiri
Omid Zobeiri
BMBehzad Moshiri
Behzad Moshiri
RNRoya Narimani
Roya Narimani
MMMohamad Mehravar
Mohamad Mehravar
MPMohamad Parnianpour
Mohamad Parnianpour
Human movement analysis is an important part of biomechanics and rehabilitation, for which many measurement systems are introduced. Among these, wearable devices have substantial biomedical applications, primarily since they can be implemented both in indoor and outdoor applications. In this study, a Trunk Motion System (TMS) using printed Body-Worn Sensors (BWS) is designed and developed. TMS can measure three-dimensional (3D) trunk motions, is lightweight, and is a portable and non-invasive system. After the recognition of sensor locations, twelve BWSs were printed on stretchable clothing with the purpose of measuring the 3D trunk movements. To integrate BWSs data, a neural network data fusion algorithm was used. The outcome of this algorithm along with the actual 3D anatomical movements (obtained by Qualisys system) were used to calibrate the TMS. Three healthy participants with different physical characteristics participated in the calibration tests. Seven different tasks (each repeated three times) were performed, involving five planar, and two multiplanar movements. Results showed that the accuracy of TMS system was less than 1.0°, 0.8°, 0.6°, 0.8°, 0.9°, and 1.3° for flexion/extension, left/right lateral bending, left/right axial rotation, and multi-planar motions, respectively. In addition, the accuracy of TMS for the identified movement was less than 2.7°. TMS, developed to monitor and measure the trunk orientations, can have diverse applications in clinical, biomechanical, and ergonomic studies to prevent musculoskeletal injuries, and to determine the impact of interventions.

16 July 2019 in Sensors
Verified
Journal Article
Open access
PDF file
Mohammad Iman Mokhlespour EsfahaniMohammad Iman Mokhlespour Esfahani
Mohammad Iman Mokhlespour Esfahani
MNMaury Nussbaum
Maury Nussbaum
Physical activities can have important impacts on human health. For example, a physically active lifestyle, which is one of the most important goals for overall health promotion, can diminish the risk for a range of physical disorders, as well as reducing health-related expenditures. Thus, a long-term goal is to detect different physical activities, and an important initial step toward this goal is the ability to classify such activities. A recent and promising technology to discriminate among diverse physical activities is the smart textile system (STS), which is becoming increasingly accepted as a low-cost activity monitoring tool for health promotion. Accordingly, our primary aim was to assess the feasibility and accuracy of using a novel STS to classify physical activities. Eleven participants completed a lab-based experiment to evaluate the accuracy of an STS that featured a smart undershirt (SUS) and commercially available smart socks (SSs) in discriminating several basic postures (sitting, standing, and lying down), as well as diverse activities requiring participants to walk and run at different speeds. We trained three classification methods—K-nearest neighbor, linear discriminant analysis, and artificial neural network—using data from each smart garment separately and in combination. Overall classification performance (global accuracy) was ~98%, which suggests that the STS was effective for discriminating diverse physical activities. We conclude that, overall, smart garments represent a promising area of research and a potential alternative for discriminating a range of physical activities, which can have positive implications for health promotion.