Omid Zobeiri

Dr. Omid Zobeiri


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 January 2017 in Sensors
Verified
Journal Article
Open access
PDF file
Mohammad Iman Mokhlespour EsfahaniMohammad Iman Mokhlespour Esfahani
Mohammad Iman Mokhlespour Esfahani
OZOmid Zobeiri
Omid Zobeiri
BMBehzad Moshiri
Behzad Moshiri
RNRoya Narimani
Roya Narimani
MMMohamad Mehravar
Mohamad Mehravar
MPMohamad Parnianpour
Mohamad Parnianpour
Human movement analysis is an important part of biomechanics and rehabilitation, for which many measurement systems are introduced. Among these, wearable devices have substantial biomedical applications, primarily since they can be implemented both in indoor and outdoor applications. In this study, a Trunk Motion System (TMS) using printed Body-Worn Sensors (BWS) is designed and developed. TMS can measure three-dimensional (3D) trunk motions, is lightweight, and is a portable and non-invasive system. After the recognition of sensor locations, twelve BWSs were printed on stretchable clothing with the purpose of measuring the 3D trunk movements. To integrate BWSs data, a neural network data fusion algorithm was used. The outcome of this algorithm along with the actual 3D anatomical movements (obtained by Qualisys system) were used to calibrate the TMS. Three healthy participants with different physical characteristics participated in the calibration tests. Seven different tasks (each repeated three times) were performed, involving five planar, and two multiplanar movements. Results showed that the accuracy of TMS system was less than 1.0°, 0.8°, 0.6°, 0.8°, 0.9°, and 1.3° for flexion/extension, left/right lateral bending, left/right axial rotation, and multi-planar motions, respectively. In addition, the accuracy of TMS for the identified movement was less than 2.7°. TMS, developed to monitor and measure the trunk orientations, can have diverse applications in clinical, biomechanical, and ergonomic studies to prevent musculoskeletal injuries, and to determine the impact of interventions.

1 September 2018 in Medical Engineering & Physics
Verified
Journal Article
Closed access
Mohammad Iman Mokhlespour EsfahaniMohammad Iman Mokhlespour Esfahani
Mohammad Iman Mokhlespour Esfahani
AAAli Akbari
Ali Akbari
OZOmid Zobeiri
Omid Zobeiri
EREhsan Rashedi
Ehsan Rashedi
MPMohamad Parnianpour
Mohamad Parnianpour
The interest in wearable systems among the biomedical engineering and clinical community continues to escalate as technical refinements enhance their potential use for both indoor and outdoor applications. For example, an important wearable technology known as a microelectromechanical system (MEMS) is demonstrating promising applications in the area of biomedical engineering. Accordingly, this study was designed to investigate the Sharif-Human Movement Instrumentation System (SHARIF-HMIS), consisting of inertial measurement units (IMUs), stretchable clothing, and a data logger-all of which can be used outside the controlled environment of a laboratory, thus enhancing its overall utility. This system is lightweight, portable, able to be deliver data for almost 10 h, and features a new data-fusion algorithm using the Kalman filter with an adaptive approach. In specific terms, the data from the system's gyroscope, accelerometer, and magnetometer sensors can be combined to estimate total-body orientation; additionally, the noise level of these sensors can be changed to accommodate faster motions as well as magnetic disturbances. These variations can be incorporated within the extended Kalman filter by changing the parameters of the filter adaptively. In specific terms, the system's interface was developed to acquire data from eighteen IMUs located on the body to collect kinematic data associated with human motion. Meanwhile, a validation test involving one subject performing different shoulder motions was designed to compare data captured by SHARIF-HMIS and the VICON motion-capture system. This validation test demonstrated correlation values of >0.9. Results also confirmed that the output accuracy of the new system's sensor was <0.55, 1.5 and 3.5° for roll, pitch, and yaw directions, respectively. In summary, SHARIF-HMIS successfully collected kinematic data for specific human movements, which has promising implications for a range of sporting, biomedical, and healthcare-related applications.