Yazine Mahjoub

Dr. Yazine Mahjoub


Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 November 2015 in Critical Care
Verified
Journal Article
Open access
PDF file
NANorair Airapetian
Norair Airapetian
JMJulien Maizel
Julien Maizel
OAOla Alyamani
Ola Alyamani
YMYazine Mahjoub
Yazine Mahjoub
ELEmmanuel Lorne
Emmanuel Lorne
MSMichel Slama
Michel Slama
Introduction: We have almost no information concerning the value of inferior vena cava (IVC) respiratory variations in spontaneously breathing ICU patients (SBP) to predict fluid responsiveness. Methods: SBP with clinical fluid need were included prospectively in the study. Echocardiography and Doppler ultrasound were used to record the aortic velocity-time integral (VTI), stroke volume (SV), cardiac output (CO) and IVC collapsibility index (cIVC) ((maximum diameter (IVCmax)– minimum diameter (IVCmin))/ IVCmax) at baseline, after a passive leg-raising maneuver (PLR) and after 500 ml of saline infusion. Results: Fifty-nine patients (30 males and 29 females; 57 ± 18 years-old) were included in the study. Of these, 29 (49 %) were considered to be responders (≥10 % increase in CO after fluid infusion). There were no significant differences between responders and nonresponders at baseline, except for a higher aortic VTI in nonresponders (16 cm vs. 19 cm, p = 0.03). Responders had a lower baseline IVCmin than nonresponders (11 ± 5 mm vs. 14 ± 5 mm, p = 0.04) and more marked IVC variations (cIVC: 35 ± 16 vs. 27 ± 10 %, p = 0.04). Prediction of fluid-responsiveness using cIVC and IVCmax was low (area under the curve for cIVC at baseline 0.62 ± 0.07; 95 %, CI 0.49-0.74 and for IVCmax at baseline 0.62 ± 0.07; 95 % CI 0.49-0.75). In contrast, IVC respiratory variations >42 % in SBP demonstrated a high specificity (97 %) and a positive predictive value (90 %) to predict an increase in CO after fluid infusion. Conclusions: In SBP with suspected hypovolemia, vena cava size and respiratory variability do not predict fluid responsiveness. In contrast, a cIVC >42 % may predict an increase in CO after fluid infusion.

1 September 2009 in Critical Care Medicine
Verified
Journal Article
Closed access
YMYazine Mahjoub
Yazine Mahjoub
CPCyrille Pila
Cyrille Pila
AFArnaud Friggeri
Arnaud Friggeri
EZElie Zogheib
Elie Zogheib
ELEric Lobjoie
Eric Lobjoie
HDHervé Dupont
Hervé Dupont
To determine whether peak systolic velocity of tricuspid annular motion assessed by tissue Doppler echocardiography (Sta), a right ventricular function parameter, can discriminate patients with true- and false-positive pulse pressure variation. Pulse pressure variation is used to predict fluid responsiveness in mechanically ventilated patients. However, this parameter has been reported to be falsely positive, especially in patients with right ventricular dysfunction. A prospective study. Medical and surgical intensive care unit of a university hospital. Thirty- five mechanically ventilated patients hospitalized for >24 hrs with a pulse pressure variation of >12%. Doppler echocardiography (including measurement of Sta and stroke volume) was performed before and after infusion of 500 mL of colloid solution. Patients were classified into two groups according to their response to fluid infusion: responders (at least 15% increase in stroke volume) and nonresponders. Twenty-three patients (66%) were responders (true-positive group) and 12 (34%) were nonresponders (false-positive group). Before volume expansion, Sta was statistically lower in the nonresponder group (0.13 [0.04] vs. 0.20 [0.05], p = .0004). The area under the curve of the receiver operating characteristic curve was 0.87 (95% confidence interval, 0.74-1). In patients with pulse pressure variation of >12%, a Sta cutoff value of 0.15 m/s discriminated between responders and nonresponders with a sensitivity of 91% (80-100) and a specificity of 83% (62-100). A Sta value of 12%.

1 September 2010 in Critical Care Medicine
Verified
Journal Article
Closed access
YMYazine Mahjoub
Yazine Mahjoub
JTJérémie Touzeau
Jérémie Touzeau
NANorair Airapetian
Norair Airapetian
ELEmmanuel Lorne
Emmanuel Lorne
MHMustapha Hijazi
Mustapha Hijazi
HDHervé Dupont
Hervé Dupont
The passive leg-raising maneuver is a reversible fluid-loading procedure used to predict fluid responsiveness in mechanically ventilated patients. The aim of the present study was to determine whether intra-abdominal hypertension (which impairs venous return) reduces the ability of passive leg raising to detect fluid responsiveness in critically ill ventilated patients. A prospective study. The medical and surgical intensive care unit of a university medical center. Forty-one mechanically ventilated patients with a pulse pressure variation of >12%. Stroke volume was continuously monitored by esophageal Doppler. Intra-abdominal pressure was measured via bladder pressure. After a passive leg-raising maneuver and a return to baseline, fluid loading with 500 mL of saline was performed. Hemodynamic parameters were recorded at each step. Nonresponders to volume loading were not analyzed (10 patients). Thirty-one patients were classified into two groups according to their response to passive leg raising: responders to passive leg raising (at least a 12% increase in stroke volume) and nonresponders to passive leg raising. Sixteen patients (52%) were responders to passive leg raising, and 15 (48%) were nonresponders to passive leg raising (i.e., false negatives). At baseline, the median intra-abdominal pressure was significantly higher in the nonresponders to passive leg raising than in the responders to passive leg raising (20 [6.5] vs. 11.5 [5.5], respectively; p < .0001). The area under the receiver-operating characteristic curve was 0.969 +/- 0.033. An intra-abdominal pressure cutoff value of 16 mm Hg discriminated between responders to passive leg raising and nonresponders to passive leg raising with a sensitivity of 100% (confidence interval, 78-100) and a specificity of 87.5% (confidence interval, 61.6-98.1). An intra-abdominal pressure of > or =16 mm Hg was the only independent predictor of nonresponse to passive leg raising in a multivariate analysis (odds ratio, 2.6 [confidence interval, 1.1-6.6]; p = .04). An intra-abdominal pressure of > or =16 mm Hg seems to be responsible for false negatives to passive leg raising. Hence, the intra-abdominal pressure should be measured in critically ill ventilated patients, especially before performing passive leg raising.

29 December 2013 in British Journal of Anaesthesia
Verified
Journal Article
Open access
PDF file
YMYazine Mahjoub
Yazine Mahjoub
VLV. Lejeune
V. Lejeune
LML. Muller
L. Muller
SPS. Perbet
S. Perbet
LZL. Zieleskiewicz
L. Zieleskiewicz
HDH. Dupont
H. Dupont
Respiratory variation in pulse pressure (ΔPP) is commonly used to predict the fluid responsiveness of critically ill patients. However, some researchers have demonstrated that this measurement has several limitations. The present study was designed to evaluate the proportion of patients satisfying criteria for valid application of ΔPP at a given time-point. A 1 day, prospective, observational, point-prevalence study was performed in 26 French intensive care units (ICUs). All patients hospitalized in the ICUs on the day of the study were included. The ΔPP validity criteria were recorded prospectively and defined as follows: (i) mechanical ventilation in the absence of spontaneous respiration; (ii) regular cardiac rhythm; (iii) tidal volume ≥8 ml kg−1 of ideal body weight; (iv) a heart rate/respiratory rate ratio >3.6; (v) total respiratory system compliance ≥30 ml cm H2O−1; and (vi) tricuspid annular peak systolic velocity ≥0.15 m s−1. The study included 311 patients with a Simplified Acute Physiology Score II of 41 (39–43). Overall, only six (2%) patients satisfied all validity criteria. Of the 170 patients with an arterial line in place, only five (3%) satisfied the validity criteria. During the 24 h preceding the study time-point, fluid responsiveness was assessed for 79 patients. ΔPP had been used to assess fluid responsiveness in 15 of these cases (19%). A very low percentage of patients satisfied all criteria for valid use of ΔPP in the evaluation of fluid responsiveness. Physicians must consider limitations to the validity of ΔPP before using this variable.

4 November 2014 in Critical Care
Verified
Journal Article
Open access
PDF file
MBMatthieu Biais
Matthieu Biais
SEStephan Ehrmann
Stephan Ehrmann
AMArnaud Mari
Arnaud Mari
BCBenjamin Conte
Benjamin Conte
YMYazine Mahjoub
Yazine Mahjoub
WGwith the collaboration of AzuRea Group
with the collaboration of AzuRea Group
Introduction: Pulse pressure variation (PPV) has been shown to predict fluid responsiveness in ventilated intensive care unit (ICU) patients. The present study was aimed at assessing the diagnostic accuracy of PPV for prediction of fluid responsiveness by using the grey zone approach in a large population. Methods: The study pooled data of 556 patients from nine French ICUs. Hemodynamic (PPV, central venous pressure (CVP) and cardiac output) and ventilator variables were recorded. Responders were defined as patients increasing their stroke volume more than or equal to 15% after fluid challenge. The receiver operating characteristic (ROC) curve and grey zone were defined for PPV. The grey zone was evaluated according to the risk of fluid infusion in hypoxemic patients. Results: Fluid challenge led to increased stroke volume more than or equal to 15% in 267 patients (48%). The areas under the ROC curve of PPV and CVP were 0.73 (95% confidence interval (CI): 0.68 to 0.77) and 0.64 (95% CI 0.59 to 0.70), respectively (P <0.001). A grey zone of 4 to 17% (62% of patients) was found for PPV. A tidal volume more than or equal to 8 ml.kg-1 and a driving pressure (plateau pressure - PEEP) more than 20 cmH2O significantly improved the area under the ROC curve for PPV. When taking into account the risk of fluid infusion, the grey zone for PPV was 2 to 13%. Conclusions: In ventilated ICU patients, PPV values between 4 and 17%, encountered in 62% patients exhibiting validity prerequisites, did not predict fluid responsiveness.

15 March 2018 in Annals of Intensive Care
Verified
Journal Article
Open access
PDF file
JTJean Louis Trouillet
Jean Louis Trouillet
OCOlivier Collange
Olivier Collange
FBFouad Belafia
Fouad Belafia
FBFrançois Blot
François Blot
GCGilles Capellier
Gilles Capellier
MGMax Guillot
Max Guillot
Tracheotomy is widely used in intensive care units, albeit with great disparities between medical teams in terms of frequency and modality. Indications and techniques are, however, associated with variable levels of evidence based on inhomogeneous or even contradictory literature. Our aim was to conduct a systematic analysis of the published data in order to provide guidelines. We present herein recommendations for the use of tracheotomy in adult critically ill patients developed using the Grading of Recommendations Assessment, Development, and Evaluation (GRADE) method. These guidelines were conducted by a group of experts from the French Intensive Care Society (Société de Réanimation de Langue Française) and the French Society of Anesthesia and Intensive Care Medicine (Société Francaise d’Anesthésie Réanimation) with the participation of the French Emergency Medicine Association (Société Française de Médecine d’Urgence), the French Society of Otorhinolaryngology. Sixteen experts and two coordinators agreed to consider questions concerning tracheotomy and its practical implementation. Five topics were defined: indications and contraindications for tracheotomy in intensive care, tracheotomy techniques in intensive care, modalities of tracheotomy in intensive care, management of patients undergoing tracheotomy in intensive care, and decannulation in intensive care. The summary made by the experts and the application of GRADE methodology led to the drawing up of 8 formal guidelines, 10 recommendations, and 3 treatment protocols. Among the 8 formal guidelines, 2 have a high level of proof (Grade 1+/−) and 6 a low level of proof (Grade 2+/−). For the 10 recommendations, GRADE methodology was not applicable and instead 10 expert opinions were produced.