Michel Slama

Prof. Michel Slama


Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 April 2017 in American Journal of Respiratory and Critical Care Medicine
Verified
Journal Article
Closed access
PVPhilippe Vignon
Philippe Vignon
XRXavier Repessé
Xavier Repessé
EBEmmanuelle Bégot
Emmanuelle Bégot
JLJulie Léger
Julie Léger
CJChristophe Jacob
Christophe Jacob
AVAntoine Vieillard-Baron
Antoine Vieillard-Baron
Rationale: Assessment of fluid responsiveness relies on dynamic echocardiographic parameters that have not yet been compared in large cohorts. Objectives: To determine the diagnostic accuracy of dynamic parameters used to predict fluid responsiveness in ventilated patients with a circulatory failure of any cause. Methods: In this multicenter prospective study, respiratory variations of superior vena cava diameter (∆SVC) measured using transesophageal echocardiography, of inferior vena cava diameter (∆IVC) measured using transthoracic echocardiography, of the maximal Doppler velocity in left ventricular outflow tract (∆VmaxAo) measured using either approach, and pulse pressure variations (∆PP) were recorded with the patient in the semirecumbent position. In each patient, a passive leg raise was performed and an increase of aortic velocity time integral greater than or equal to 10% defined fluid responsiveness. Measurements and Main Results: Among 540 patients (379 men; age, 65 ± 13 yr; Simplified Acute Physiological Score II, 59 ± 18; Sequential Organ Failure Assessment, 10 ± 3), 229 exhibited fluid responsiveness (42%). ∆PP, ∆VmaxAo, ∆SVC, and ∆IVC could be measured in 78.5%, 78.0%, 99.6%, and 78.1% of cases, respectively. ∆SVC greater than or equal to 21%, ∆VmaxAo greater than or equal to 10%, and ∆IVC greater than or equal to 8% had a sensitivity of 61% (95% confidence interval, 57–66%), 79% (75–83%), and 55% (50–59%), respectively, and a specificity of 84% (81–87%), 64% (59–69%), and 70% (66–75%), respectively. The area under the receiver operating characteristic curve of ∆SVC was significantly greater than that of ∆IVC (P = 0.02) and ∆PP (P = 0.01). Conclusions: ∆VmaxAo had the best sensitivity and ∆SVC the best specificity in predicting fluid responsiveness. ∆SVC had a greater diagnostic accuracy than ∆IVC and ∆PP, but its measurement requires transesophageal echocardiography.

1 January 2020 in Annals of Intensive Care
Verified
Journal Article
Open access
PDF file
jean-francois timsitjean-francois timsit
jean-francois timsit
JBJulien Baleine
Julien Baleine
LBLouis Bernard
Louis Bernard
SCSilvia Calvino-Gunther
Silvia Calvino-Gunther
Michel DARMONMichel DARMON
Michel DARMON
VMVirginie Maxime
Virginie Maxime
The French Society of Intensive Care Medicine (SRLF), jointly with the French-Speaking Group of Paediatric Emergency Rooms and Intensive Care Units (GFRUP) and the French-Speaking Association of Paediatric Surgical Intensivists (ADARPEF), worked out guidelines for the management of central venous catheters (CVC), arterial catheters and dialysis catheters in intensive care unit. For adult patients: Using GRADE methodology, 36 recommendations for an improved catheter management were produced by the 22 experts. Recommendations regarding catheter-related infections’ prevention included the preferential use of subclavian central vein (GRADE 1), a one-step skin disinfection(GRADE 1) using 2% chlorhexidine (CHG)-alcohol (GRADE 1), and the implementation of a quality of care improvement program. Antiseptic- or antibiotic-impregnated CVC should likely not be used (GRADE 2, for children and adults). Catheter dressings should likely not be changed before the 7th day, except when the dressing gets detached, soiled or impregnated with blood (GRADE 2− adults). CHG dressings should likely be used (GRADE 2+). For adults and children, ultrasound guidance should be used to reduce mechanical complications in case of internal jugular access (GRADE 1), subclavian access (Grade 2) and femoral venous, arterial radial and femoral access (Expert opinion). For children, an ultrasound-guided supraclavicular approach of the brachiocephalic vein was recommended to reduce the number of attempts for cannulation and mechanical complications. Based on scarce publications on diagnostic and therapeutic strategies and on their experience (expert opinion), the panel proposed definitions, and therapeutic strategies.

17 May 2007 in Intensive Care Medicine
Verified
Journal Article
Closed access
PDF file
JMJulien Maizel
Julien Maizel
NANorair Airapetian
Norair Airapetian
ELEmmanuel Lorne
Emmanuel Lorne
CTChristophe Tribouilloy
Christophe Tribouilloy
ZMZiad Massy
Ziad Massy
MSMichel Slama
Michel Slama

13 November 2015 in Critical Care
Verified
Journal Article
Open access
PDF file
NANorair Airapetian
Norair Airapetian
JMJulien Maizel
Julien Maizel
OAOla Alyamani
Ola Alyamani
YMYazine Mahjoub
Yazine Mahjoub
ELEmmanuel Lorne
Emmanuel Lorne
MSMichel Slama
Michel Slama
Introduction: We have almost no information concerning the value of inferior vena cava (IVC) respiratory variations in spontaneously breathing ICU patients (SBP) to predict fluid responsiveness. Methods: SBP with clinical fluid need were included prospectively in the study. Echocardiography and Doppler ultrasound were used to record the aortic velocity-time integral (VTI), stroke volume (SV), cardiac output (CO) and IVC collapsibility index (cIVC) ((maximum diameter (IVCmax)– minimum diameter (IVCmin))/ IVCmax) at baseline, after a passive leg-raising maneuver (PLR) and after 500 ml of saline infusion. Results: Fifty-nine patients (30 males and 29 females; 57 ± 18 years-old) were included in the study. Of these, 29 (49 %) were considered to be responders (≥10 % increase in CO after fluid infusion). There were no significant differences between responders and nonresponders at baseline, except for a higher aortic VTI in nonresponders (16 cm vs. 19 cm, p = 0.03). Responders had a lower baseline IVCmin than nonresponders (11 ± 5 mm vs. 14 ± 5 mm, p = 0.04) and more marked IVC variations (cIVC: 35 ± 16 vs. 27 ± 10 %, p = 0.04). Prediction of fluid-responsiveness using cIVC and IVCmax was low (area under the curve for cIVC at baseline 0.62 ± 0.07; 95 %, CI 0.49-0.74 and for IVCmax at baseline 0.62 ± 0.07; 95 % CI 0.49-0.75). In contrast, IVC respiratory variations >42 % in SBP demonstrated a high specificity (97 %) and a positive predictive value (90 %) to predict an increase in CO after fluid infusion. Conclusions: In SBP with suspected hypovolemia, vena cava size and respiratory variability do not predict fluid responsiveness. In contrast, a cIVC >42 % may predict an increase in CO after fluid infusion.

9 June 2017 in Critical Care
Verified
Journal Article
Open access
PDF file
PMPablo Mercado
Pablo Mercado
JMJulien Maizel
Julien Maizel
CBChristophe Beyls
Christophe Beyls
DTDimitri Titeca-Beauport
Dimitri Titeca-Beauport
MJMagalie Joris
Magalie Joris
MSMichel Slama
Michel Slama
Cardiac output (CO) monitoring is a valuable tool for the diagnosis and management of critically ill patients. In the critical care setting, few studies have evaluated the level of agreement between CO estimated by transthoracic echocardiography (CO-TTE) and that measured by the reference method, pulmonary artery catheter (CO-PAC). The objective of the present study was to evaluate the precision and accuracy of CO-TTE relative to CO-PAC and the ability of transthoracic echocardiography to track variations in CO, in critically ill mechanically ventilated patients. Thirty-eight mechanically ventilated patients fitted with a PAC were included in a prospective observational study performed in a 16-bed university hospital ICU. CO-PAC was measured via intermittent thermodilution. Simultaneously, a second investigator used standard-view TTE to estimate CO-TTE as the product of stroke volume and the heart rate obtained during the measurement of the subaortic velocity time integral. Sixty-four pairs of CO-PAC and CO-TTE measurements were compared. The two measurements were significantly correlated (r = 0.95; p < 0.0001). The median bias was 0.2 L/min, the limits of agreement (LOAs) were –1.3 and 1.8 L/min, and the percentage error was 25%. The precision was 8% for CO-PAC and 9% for CO-TTE. Twenty-six pairs of ΔCO measurements were compared. There was a significant correlation between ΔCO-PAC and ΔCO-TTE (r = 0.92; p < 0.0001). The median bias was –0.1 L/min and the LOAs were –1.3 and +1.2 L/min. With a 15% exclusion zone, the four-quadrant plot had a concordance rate of 94%. With a 0.5 L/min exclusion zone, the polar plot had a mean polar angle of 1.0° and a percentage error LOAs of –26.8 to 28.8°. The concordance rate was 100% between 30 and –30°. When using CO-TTE to detect an increase in ΔCO-PAC of more than 10%, the area under the receiving operating characteristic curve (95% CI) was 0.82 (0.62–0.94) (p < 0.001). A ΔCO-TTE of more than 8% yielded a sensitivity of 88% and specificity of 66% for detecting a ΔCO-PAC of more than 10%. In critically ill mechanically ventilated patients, CO-TTE is an accurate and precise method for estimating CO. Furthermore, CO-TTE can accurately track variations in CO.

17 June 2015 in Critical Care
Verified
Journal Article
Open access
PDF file
JCJean-Louis Chauvet
Jean-Louis Chauvet
SEShari El-Dash
Shari El-Dash
ODOlivier Delastre
Olivier Delastre
BBBernard Bouffandeau
Bernard Bouffandeau
DJDominique Jusserand
Dominique Jusserand
MSMichel Slama
Michel Slama
Introduction: Based on previously published case reports demonstrating dynamic left intraventricular obstruction (IVO) triggered by hypovolemia or catecholamines, this study aimed to establish: (1) IVO occurrence in septic shock patients; (2) correlation between the intraventricular gradient and volume status and fluid responsiveness; and (3) mortality rate.Method: We prospectively analyzed patients with septic shock admitted to a general ICU over a 28-month period who presented Doppler signs of IVO. Clinical characteristics and hemodynamic parameters as well as echocardiographic data regarding left ventricular function, size, and calculated mass, and left ventricular outflow Doppler pattern and velocity before and after fluid infusions were recorded.Results: During the study period, 218 patients with septic shock were admitted to our ICU. IVO was observed in 47 (22 %) patients. Mortality rate at 28 days was found to be higher in patients with than in patients without IVO (55 % versus 33 %,p< 0.01). Small, hypercontractile left ventricles (end-diastolic left ventricular surface 4.7 ± 2.1 cm2/m2and ejection fraction 82 ± 12 %), and frequent pseudohypertrophy were found in these patients. A rise ≥12 % in stroke index was found in 87 % of patients with IVO, with a drop of 47 % in IVO after fluid infusion.Conclusion: Left IVO is a frequent event in septic shock patients with an important correlation with fluid responsiveness. The mortality rate was found to be higher in these patients in comparison with patients without obstruction.