Chunmei Guo

Prof. Dr. Chunmei Guo

School of Energy and Safety Engineering, Tianjin Chengjian University, Tianjin 300384, China

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 August 2024 in Energies
Verified
Journal Article
Open access
PDF file
Yuwen YouYuwen You
Yuwen You
ZWZhonghua Wang
Zhonghua Wang
ZLZhihao Liu
Zhihao Liu
Chunmei GuoChunmei Guo
Chunmei Guo
Bin YangBin Yang
Bin Yang
Cogeneration is an important means for heat supply enterprises to obtain heat, and accurate load prediction is particularly crucial. The heat load of a centralized heat supply system is influenced by various factors such as outdoor meteorological parameters, the building envelope structure, and regulation control, which exhibit a strong coupling and nonlinearity. It is essential to identify the key variables affecting the heat load at different heating stages through data mining techniques and to use deep learning algorithms to precisely regulate the heating system based on load predictions. In this study, a heat station in a northern Chinese city is taken as the subject of research. We apply the Fuzzy Clustering based on Fourier distance (FCBD-FCM) algorithm to transform the factors influencing the long and short-term load prediction of heat supply from the time domain to the frequency domain. This transformation is used to analyze the degree of their impact on load changes and to extract factors with significant influence as the multifeatured input variables for the prediction model. Five neural network models for load prediction are established, namely, Backpropagation (BP), convolutional neural network (CNN), Long Short-Term Memory (LSTM), CNN-LSTM, and CNN-BiLSTM. These models are compared and analyzed for their performance in long-term, short-term, and ultrashort-term heating load prediction. The findings indicate that the load prediction accuracy is high when multifeatured input variables are based on fuzzy clustering. Furthermore, the CNN-BiLSTM model notably enhances the prediction accuracy and generalization ability compared to other models, with the Mean Absolute Percentage Error (MAPE) averaging within 3%.

28 April 2023 in Sustainability
Verified
Journal Article
Open access
PDF file
Chunmei GuoChunmei Guo
Chunmei Guo
YLYu Li
Yu Li
XLXianli Li
Xianli Li
RBRuxue Bai
Ruxue Bai
Chuanshuai DongChuanshuai Dong
Chuanshuai Dong
In order to promote the engineering application of indirect evaporative cooling (IEC) in the field of building air conditioning, as well as reduce air conditioning energy consumption and carbon emissions, this paper proposes a fresh air unit using indirect evaporative cooling to achieve heat recovery from exhaust air, which gives the recommended values of air and spray water operation parameters. The indirect evaporative cooler heat and mass transfer mathematical model and numerical solution procedure were made. In summer outdoor design conditions, the fresh air outlet state parameters, cooling capacity, fresh air cooling load, wet bulb efficiency and enthalpy efficiency were numerically solved for thirty typical cities from five climate zones of China. In addition, also based on the model results for the cities in China, two representative operating conditions points of medium and high humidity were selected. Eight models of fresh air unit coolers in the air volume range of 1000–10,000 m3/h commonly used in engineering were simulated to obtain the optimal heat transfer area and size selection of ERIEC heat exchangers for fresh air units, and economic analysis was performed. The results show that the wet bulb efficiency ranges from 0.67–0.98, and increases as the outdoor design wet bulb temperature decreases; the enthalpy efficiency ranges from 0.76–1.29, and increases as the outdoor design wet bulb temperature increases; and the fresh air load that the exhaust air heat recovery type indirect evaporative cooler can bear ranges from 55–100%, which could largely decrease the cold load of the matched surface cooler. As demonstrated, the energy-saving effect is remarkable.