Houassine Hamza

Prof. Houassine Hamza

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2022 in Russian Journal of Nondestructive Testing
Verified
Journal Article
Closed access
PDF file
HEHassane Ezziane
Hassane Ezziane
HHHouassine Hamza
Houassine Hamza
SMSamir Moulahoum
Samir Moulahoum
MCMoustafa Sahnoune Chaouche
Moustafa Sahnoune Chaouche
Currently, the adoption of artificial intelligence is an inevitable necessity in diagnosing electrical systems failures, also, frequency response analysis FRA is widely used as a tool for diagnostic mechanical and electrical faults in power transformers, in this paper, a new methodology was proposed based on machine learning and advanced diagnostic technique FRA for detecting the type, location and severity of transformer fault. The method was applied and test it on three common actual defects (viz. axial displacement (AD), radial displacement (RD), and short circuit (SC)) that have been applied practically to an actual transformer winding at various locations and with different levels. Initially, the proposed approach is based on the collection and interpretation of the frequency response analysis (FRA) data of the winding faults to construct a database that can confine all possible cases of the fault and this has been tried with AD fault. After that, before classification, the problem of imbalance in the databases is addressed. Therefore, a support vector machine (SVM) classifier combined with SMOTE data preprocessing algorithm has been suggested to solve the imbalance problem. The performance of the suggested methodology was evaluated using experimental data collected from the winding transformer model. Where the results prove the ability of the proposed method to detect the type, locate and severity of the fault with high accuracy than other methods, which may effectively contribute to the development of machine learning reliance for the diagnosis of the power transformer faults.

1 June 2022 in Russian Journal of Nondestructive Testing
Verified
Journal Article
Closed access
PDF file
RCRachid Sahnoune Chaouche
Rachid Sahnoune Chaouche
HHHouassine Hamza
Houassine Hamza
SMSamir Moulahoum
Samir Moulahoum
MCMoustafa Sahnoune Chaouche
Moustafa Sahnoune Chaouche
SBSamir BENSAID
Samir BENSAID
Transfer function and state-space model are two powerful complementary tools have been used to monitoring the physical system. These two ways can be very successful in giving a comprehensive analysis of electrical power transformer malfunctions. This paper proposes a novel robust approach nondestructive to diagnose short circuit (SC) faults by considering axial displacements (AD) in the transformer winding. Initially, elaboration a native autonomously tool to control the LCR meters through computing systems. This platform will control the impedance measurement by the instrument of the LCR meter through MATLAB software. Additionally, achieving estimation autonomously to all the parameters of the lumped equivalent model of the winding accurately using frequency response analysis signal morphology interpretation (FRASMI). On the other hand, obtaining a new representation of the state-space model of the lumped equivalent model of an isolated winding with SC fault between its turns to locate and assess its severity. Finally, the relationship between the model parameters and the resonance frequencies of the frequency response curve can provide an effective nondestructive diagnostic tool for all mechanical damages of winding (e.g., SC with AD) which have been implemented experimentally, in which a new physical index has been proposed making it possible to locate and assess the extent of these defects simultaneously.

18 April 2018 in Open Physics
Verified
Journal Article
Open access
PDF file
MCMoustafa Sahnoune Chaouche
Moustafa Sahnoune Chaouche
SMSamir Moulahoum
Samir Moulahoum
HHHouassine Hamza
Houassine Hamza
The behavior analysis of the transformer is usually achieved by the frequency response analysis (FRA), which is obtained by the application of a very low AC voltage in over a wide frequency range. This paper presents a low and high frequency modelling approach of a three-phase transformer. The developed model consists of a cascade of parallel RLC cells, whose parameters are identified using the frequency response analysis data measurements obtained on each transformer phase. Thus, the proposed model can simulate the frequency behavior of the transformer windings without reference to the geometries of the coils which makes it easily usable in the failure diagnosis field. Experimental results on a 300 VA laboratory transformer validate the proposed model.

1 April 2023 in Russian Journal of Nondestructive Testing
Verified
Journal Article
Closed access
PDF file
ACAbdallah Chanane
Abdallah Chanane
MBMessaoud Belazzoug
Messaoud Belazzoug
HHHouassine Hamza
Houassine Hamza
Frequency response analysis (FRA) is considered as a reliable method for the diagnosis of the power transformer winding. Despite this popularity, interpretation of FRA signatures has challenges steel. This paper proposes an elegant and a robust decentralized computation methodology based on logistic chaotic JAYA algorithm (LCJAYA) to construct a high frequency mutually coupled equivalent circuit (HF-MCEC) of the transformer winding for diagnosis purposes. The decentralized HF-MCEC is firstly built from three frequency sub-bands (low, medium, and high frequency) separately. Afterwards, the synthesized LCJAYA algorithm with high efficiency and the mathematical model for HF-MCEC are elaborated. As well, the optimisation methods have difficulties in identifying the nearly unique equivalent circuit parameter in a large search space area. The proposed methodology uses two main strategies. At first, a logistic chaotic to enhance the population diversity and to improve the exploration search areas. Then, a chaotic mutation strategy to improve the exploration and the exploitation at different search process. The success of the proposed study can be imputed to a careful physical correlation between the inductances, capacitances, resistances parameters and their natural frequencies. FRA measurements has been conducted on transformer winding models. The performance of the proposed method is evaluated and compared under different cases.

1 August 2024 in Russian Journal of Nondestructive Testing
Verified
Journal Article
Closed access
PDF file
ACAbdallah Chanane
Abdallah Chanane
HHHouassine Hamza
Houassine Hamza
Frequency response analysis (FRA) is the widely used technique for diagnosis of power transformer winding. Previous works in the field of FRA have steer to the standardization of its measurements procedure. To date, there is no reliable standard code for the interpretation of FRA results. In this context, this paper proposes a new parametric method to synthesis the High frequency electrical ladder network circuit (HF-ELNC) of the transformer winding. Initially, a nondestructive process is applied to extract three main winding parameters. Mainly, the shunt-series capacitances and the total equivalent inductance basing on the frequency response data from the winding terminal. To this end, the proposed continuous-time state–space model is converted into a gain-numerator-denominator form. After that, the derived matrix equations are iteratively estimated by population-based algorithm using enhanced logistic choatic marine predator algorithm (ELCMPA), from where, three objective functions are considered in the model of identification including the capacitances, the inductances and the resistances. As well, classical methods such as finite elements or analytical formulas require design winding specifications. In this study, instead of winding geometry knowledge, the proposed method certifies a unique, physically and mutually coupled HF-ELNC. The accuracy of the proposed method is validated through case study of a real transformer winding.

1 August 2013
Verified
Conference Paper
Closed access
NKnadir Kabeche
nadir Kabeche
SMSamir Moulahoum
Samir Moulahoum
HHHouassine Hamza
Houassine Hamza
The present paper described the implementation of an adaptive scheme of the direct field oriented control (DRFOC) for an induction motor. A nonlinear estimator is suggested to estimate the rotor time constant inverse and thereafter it will be used with motor model to estimate the rotor flux. Both rotor flux and parameter estimations are hardware performed by using the Xilinx System Generator (XSG) for DSP within the Matlab/Simulink environment.