Abdallah Chanane

Dr. Abdallah Chanane

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2023 in Russian Journal of Nondestructive Testing
Verified
Journal Article
Closed access
PDF file
ACAbdallah Chanane
Abdallah Chanane
MBMessaoud Belazzoug
Messaoud Belazzoug
HHHouassine Hamza
Houassine Hamza
Frequency response analysis (FRA) is considered as a reliable method for the diagnosis of the power transformer winding. Despite this popularity, interpretation of FRA signatures has challenges steel. This paper proposes an elegant and a robust decentralized computation methodology based on logistic chaotic JAYA algorithm (LCJAYA) to construct a high frequency mutually coupled equivalent circuit (HF-MCEC) of the transformer winding for diagnosis purposes. The decentralized HF-MCEC is firstly built from three frequency sub-bands (low, medium, and high frequency) separately. Afterwards, the synthesized LCJAYA algorithm with high efficiency and the mathematical model for HF-MCEC are elaborated. As well, the optimisation methods have difficulties in identifying the nearly unique equivalent circuit parameter in a large search space area. The proposed methodology uses two main strategies. At first, a logistic chaotic to enhance the population diversity and to improve the exploration search areas. Then, a chaotic mutation strategy to improve the exploration and the exploitation at different search process. The success of the proposed study can be imputed to a careful physical correlation between the inductances, capacitances, resistances parameters and their natural frequencies. FRA measurements has been conducted on transformer winding models. The performance of the proposed method is evaluated and compared under different cases.

1 August 2024 in Russian Journal of Nondestructive Testing
Verified
Journal Article
Closed access
PDF file
ACAbdallah Chanane
Abdallah Chanane
HHHouassine Hamza
Houassine Hamza
Frequency response analysis (FRA) is the widely used technique for diagnosis of power transformer winding. Previous works in the field of FRA have steer to the standardization of its measurements procedure. To date, there is no reliable standard code for the interpretation of FRA results. In this context, this paper proposes a new parametric method to synthesis the High frequency electrical ladder network circuit (HF-ELNC) of the transformer winding. Initially, a nondestructive process is applied to extract three main winding parameters. Mainly, the shunt-series capacitances and the total equivalent inductance basing on the frequency response data from the winding terminal. To this end, the proposed continuous-time state–space model is converted into a gain-numerator-denominator form. After that, the derived matrix equations are iteratively estimated by population-based algorithm using enhanced logistic choatic marine predator algorithm (ELCMPA), from where, three objective functions are considered in the model of identification including the capacitances, the inductances and the resistances. As well, classical methods such as finite elements or analytical formulas require design winding specifications. In this study, instead of winding geometry knowledge, the proposed method certifies a unique, physically and mutually coupled HF-ELNC. The accuracy of the proposed method is validated through case study of a real transformer winding.

19 August 2026 in Energies
Verified
Journal Article
Open access
PDF file
EIEssam Hassan Abdou Ibraheem
Essam Hassan Abdou Ibraheem
MEMohamed Ebeed
Mohamed Ebeed
AFAisha Fathy Fareed
Aisha Fathy Fareed
emad Abdelnabi mohamed Younisemad Abdelnabi mohamed Younis
emad Abdelnabi mohamed Younis
Mokhtar AlyMokhtar Aly
Mokhtar Aly
AAAdel Fathy Khalifa Agamy
Adel Fathy Khalifa Agamy
Recently, microgrid (MG) structures include a mix of renewable energy sources (RES) and conventional sources. At high levels of RES penetration, reduced inertia and frequency stability have been confirmed in several studies. Properly designed and structured load frequency control (LFC) and virtual inertia control (VIC) are feasible solutions to these problems. In this paper, a new hybridized two-degree-of-freedom (2DOF) non-integer controller is proposed for multi-generation, multi-area MGs’ frequency regulation. The proposed new LFC is based on a 2DOF tilt-integral/tilt-derivative-double-derivative controller with a filter (TI-TD2F2). Meanwhile, the proposed design process considers coordinating capacitive energy storage (CES) to help regulate frequency deviation, as well as the high penetration of RESs (wind and PV). The incorporation of CES participation in frequency regulation helps provide fast VIC for the studied multi-MG system. Furthermore, an Enhanced Escape Algorithm (EESC) optimization algorithm is proposed to simultaneously optimize the control parameter set of the two-area MG system. The proposed EESC optimization algorithm identifies appropriate parameters for controller design, yielding better overall dynamic performance. An enhanced Escape Algorithm (EESC) is based on boosting the searching mechanism of the conventional Escape Algorithm by the integration of three modifications, including the Chaos map logistic mutation mechanism, the Fitness distance balance mechanism, and the Sorted Quasi-oppositional based learning (SQOBL). The proposed 2DOF TI-TD2F2 controller demonstrates improved frequency stability and sustainable operation under load changes, variation in RESs, and other uncertainties of system parameters. The obtained results showed that the proposed EESC optimization algorithm adjusts the parameters of the TI-TD2F2 controller, which significantly improves the dynamic performance in load frequency and tie-line power control. Compared to traditional TID and FOPID controllers, TI-TD2F2 achieves up to a 70–80% reduction in tie-line power deviation and up to 60% faster settling time in many scenarios, demonstrating better robustness, faster response, and better overall system stability.