chaoqun xu

Dr. chaoqun xu


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 February 2022 in Metals
Verified
Journal Article
Open access
PDF file
LYLi Yang
Li Yang
CaiHong LiCaiHong Li
CaiHong Li
SZSong Zhang
Song Zhang
CXchaoqun xu
chaoqun xu
HCHun Chen
Hun Chen
YLYongxin Li
Yongxin Li
The fluxgate magnetometer has the advantages of having a small volume and low power consumption and being light weight and is commonly used to detect weak magnetic targets, including ferrous metals, unexploded bombs (UXOs), and underground corrosion pipelines. However, the detection accuracy of the fluxgate magnetometer is affected by its own error. To obtain more accurate detection data, the sensor must be error-corrected before application. Previous researchers easily fell into the local minimum when solving error parameters. In this paper, the error correction method was proposed to tackle the problem, which combines the Dragonfly algorithm (DA) and the Levenberg–Marquardt (LM) algorithm, thereby solving the problem of the LM algorithm and improving the accuracy of solving error parameters. Firstly, we analyzed the error sources of the three-axis magnetic sensor and established the error model. Then, the error parameters were solved by using the LM algorithm and DA–LM algorithm, respectively. In addition, by comparing the results of the two methods, we found that the error parameters solved by using the DA–LM algorithm were more accurate. Finally, the magnetic measurement data were corrected. The simulation results show that the DA–LM algorithm can accurately solve the error parameters of the triaxial magnetic sensor, proving the effectiveness of the proposed algorithm. The experimental results show that the difference between the corrected and the ideal total value was decreased from 300 nT to 5 nT, which further verified the effectiveness of the DA–LM algorithm.

1 February 2020 in IOP Conference Series: Earth and Environmental Science
Verified
Conference Paper
Open access
CXchaoqun xu
chaoqun xu
KHKui Huang
Kui Huang
SZShaohua Zhang
Shaohua Zhang
LMLifei Meng
Lifei Meng
Aiming at the measurement errors caused by non-orthogonality, inconsistent sensitivity, zero-offset of the tri-axis fluxgate sensor and the position misalignment of two fluxgate sensors composed of the gradiometer, this paper establishes the correction model of measurement error of magnetometer and gradiometer, puts forward the comprehensive coefficient method, and uses the non-magnetic turntable to calibrate the Mag648 three-axis magnetometer and gradiometer in the uniform magnetic environment. The experimental results show that the method can reduce the maximum total magnetic field deviation of the two magnetometers from 552.4 nT to 15.0 nT, and reduce the maximum output deviation of the three-component gradiometer from 3891.5 nT to 37.2 nT, which effectively improves the reliability of the three-axis magnetic sensor in measurement.

7 December 2021 in Metals
Verified
Journal Article
Open access
PDF file
CXchaoqun xu
chaoqun xu
LYLi Yang
Li Yang
KHKui Huang
Kui Huang
YGYang Gao
Yang Gao
SZShaohua Zhang
Shaohua Zhang
ZYZhong Yi
Zhong Yi
The ocean is a very important arena in modern warfare where all marine powers deploy their military forces. Due to the complex environment of the ocean, underwater equipment has become a very threatening means of surprise attack in modern warfare. Therefore, the timely and effective detection of underwater moving targets is the key to obtaining warfare advantages and has important strategic significance for national security. In this paper, magnetic flux induction technology was studied with regard to the difficulty of detecting underwater concealed moving targets. Firstly, the characteristics of a magnetic target were analyzed and an equivalent magnetic dipole model was established. Secondly, the structure of the rectangular induction coil was designed according to the model, and the relationship between the target’s magnetism and the detection signal was deduced. The variation curves of the magnetic flux and the electromotive force induced in the coil were calculated by using the numerical simulation method, and the effects of the different motion parameters of the magnetic dipole and the size parameters of the coil on the induced electromotive force were analyzed. Finally, combined with the wavelet threshold filter, a series of field tests were carried out using ships of different materials in shallow water in order to verify the moving target detection method based on magnetic flux induction technology. The results showed that this method has an obvious response to moving targets and can effectively capture target signals, which verifies the feasibility of the magnetic flux induction detection technology.

21 March 2024
Verified
Book Chapter
Open access
PDF file
YZYuanpeng Zhang
Yuanpeng Zhang
KHKui Huang
Kui Huang
SZShaohua Zhang
Shaohua Zhang
CXchaoqun xu
chaoqun xu
QXQi Xiao
Qi Xiao
XTXiaojin Tang
Xiaojin Tang
The gradient magnetic field has been widely used in biomedicine and other fields. Electrical coils are often used in engineering to generate the required magnetic field. In practical application, the uniformity of the magnetic gradient coil has a great influence on the accuracy of measuring point positioning of the magnetic sensor. In this paper, the gradient uniformity is taken as the optimization goal, and the sequential quadratic programming (SQP) algorithm is creatively used to study the coil design and optimization method. Firstly, based on the design of the standard Helmholtz coil configuration, the parameters to be optimized are determined. The objective function of the magnetic field gradient uniformity is then established, and the objective function is iteratively optimized by the SQP optimization algorithm. Numerical simulation results show that the gradient uniformity of the magnetic field is greatly improved by optimizing the coil configuration.