Li Yang

Li Yang


Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 November 2024 in IEEE Transactions on Geoscience and Remote Sensing
Verified
Journal Article
Closed access
ZLZhiyu Lu
Zhiyu Lu
LYLi Yang
Li Yang
BWBin Wang
Bin Wang
KWKun Wu
Kun Wu
YLYongxin Li
Yongxin Li
XZXiaoping Zheng
Xiaoping Zheng
Magnetic sensor arrays are typically used to detect magnetic targets. Currently, research on sensor array calibration focuses on solving the problems of inconsistent sensitivity, zero offset, and non-orthogonality in individual sensors, and misalignment errors between sensors. However, in magnetic field detection, sensor arrays are usually mounted on a platform or carried as a handheld device and are prone to random swaying during the detection process, leading to changes in the attitude and position of the magnetic sensors, which in turn generates swaying errors. In this study, the source of swaying error in sensor arrays was first analyzed theoretically, and a swaying error model of a magnetic sensor was established. Second, an swaying error calibration method was proposed in combination with the classical prediction model— Gaussian Process Regression (GPR), Backpropagation Neural Network (BP) and Support Vector Machine (SVM) in the field of artificial intelligence. The experimental results show that the prediction performance based on the BP neural network is the most outstanding. After correction, the relative error percentage of the swaying error in the magnetic field data decreased significantly from 165.50% to 9.35%, which is a significant improvement of the correction effect. In addition, we conducted model comparison experiments in different environments, and the results show that the BP model performs well in various environments, demonstrating its strong generalization ability and robustness. Finally, the distance error of the magnetic dipole position was significantly reduced after calibration, from 1.56 m, 1.12 m, and 2.50 m to 0.17 m, 0.04 m, and 0.04 m, respectively. Thus, the effectiveness of the calibration method was verified.

28 November 2014 in Asian Pacific Journal of Cancer Prevention
Verified
Journal Article
Open access
PDF file
LYLi Yang
Li Yang
XHXianhe Huang
Xianhe Huang
LSLiang Sun
Liang Sun
A Piezoelectric Immunosensor for Early Cervical Cancer Detection Quartz crystal microbalance;immunosensor;early cervical cancer;detection; Background: A piezoelectric immunosensor for early cervical cancer detection was developed involving short analyis time and less invasive technique for $p16^{INK4a}$, a protein that has been linked to cervical cancer. Materials and Methods: $5{\mu}L$ of 5.0 mg/mL $p16^{INK4a}$ antibody and then supernatant from different clinical samples from West China Second University Hospital (Sichuan, China) were dripped on the center of the AT-cut crystal through a micro-injector. Absorption of the $p16^{INK4a}$ by antibody caused a shift in the resonant frequency of the immunosensor, and the resonant frequency was correlated to the amount of the $p16^{INK4a}$ in the supernatant. Results: The greater severity of lesion grading, the greater the expression level of $p16^{INK4a}$. Conclusion: Degree of cervical cancer lesion development could be determined by detected amount of $p16^{INK4a}$ in different clinical samples.

4 March 2025 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
LYLi Yang
Li Yang
ZLZhiyu Lu
Zhiyu Lu
BWBin Wang
Bin Wang
KWKun Wu
Kun Wu
XZXiaoping Zheng
Xiaoping Zheng
The difficulty in magnetic multi-target recognition is that it is difficult to recognize magnetic targets with different magnetic moments and different depths at the same time. This is because the magnetic moment and depth of a magnetic target affect the strength of the generated magnetic field information, resulting in localization results that favor targets that generate stronger magnetic fields, while targets with weaker magnetic fields cannot be accurately identified. In addition, the traditional Euler equation-based multi-target localization method requires calibration of the sensor array before detection, which requires high calibration accuracy as it relies on the inversion of mathematical equations to solve for magnetic targets. To address this problem, this paper proposes an inverse tangent function imaging processing method based on the magnetic gradient tensor information (MGT) depth direction change rate. The method aims to balance the differences in magnetic field information between different magnetic targets and enhance the recognition of the horizontal position of targets with weaker magnetic fields. Based on this, a depth detection method based on MGT is proposed to acquire the depth information of magnetic targets. A grid-format data acquisition method is also proposed to obtain the MGT. The method does not require calibration of the sensor array or separation of the magnetic anomaly field from the total field. Simulation and experimental results show that the positioning error of this method for each magnetic target in the x, y, and z axes is less than 0.15 m. For a magnetic target with a depth of 1 m, the x-axis error is 0.15 m, the y-axis error is 0.05 m, and the z-axis error is 0.06 m. For a magnetic target with a depth of 0.7 m, the x-axis error is 0.08 m, the y-axis error is 0.12 m, and the z-axis error is 0.13 m.

7 December 2021 in Metals
Verified
Journal Article
Open access
PDF file
CXchaoqun xu
chaoqun xu
LYLi Yang
Li Yang
KHKui Huang
Kui Huang
YGYang Gao
Yang Gao
SZShaohua Zhang
Shaohua Zhang
ZYZhong Yi
Zhong Yi
The ocean is a very important arena in modern warfare where all marine powers deploy their military forces. Due to the complex environment of the ocean, underwater equipment has become a very threatening means of surprise attack in modern warfare. Therefore, the timely and effective detection of underwater moving targets is the key to obtaining warfare advantages and has important strategic significance for national security. In this paper, magnetic flux induction technology was studied with regard to the difficulty of detecting underwater concealed moving targets. Firstly, the characteristics of a magnetic target were analyzed and an equivalent magnetic dipole model was established. Secondly, the structure of the rectangular induction coil was designed according to the model, and the relationship between the target’s magnetism and the detection signal was deduced. The variation curves of the magnetic flux and the electromotive force induced in the coil were calculated by using the numerical simulation method, and the effects of the different motion parameters of the magnetic dipole and the size parameters of the coil on the induced electromotive force were analyzed. Finally, combined with the wavelet threshold filter, a series of field tests were carried out using ships of different materials in shallow water in order to verify the moving target detection method based on magnetic flux induction technology. The results showed that this method has an obvious response to moving targets and can effectively capture target signals, which verifies the feasibility of the magnetic flux induction detection technology.

14 February 2025 in Measurement
Verified
Journal Article
Closed access
LYLi Yang
Li Yang
ZLZhiyu Lu
Zhiyu Lu
XTXiaoyu Tang
Xiaoyu Tang
BWBin Wang
Bin Wang
XZXiaoping Zheng
Xiaoping Zheng

12 February 2024 in Modelling and Simulation in Materials Science and Engineering
Verified
Journal Article
Closed access
JXJianping Xiao
Jianping Xiao
LYLi Yang
Li Yang
SWShuqun Wang
Shuqun Wang
Accurate and rapid bandgap prediction is a fundamental task in materials science. We propose graph neural networks with transfer learning to overcome the scarcity of training data for high-fidelity bandgap predictions. We also add a perturbation-based component to our framework to improve explainability. The experimental results show that a framework consisting of graph-level pre-training and standard fine-tuning achieves superior performance on all high-fidelity bandgap prediction tasks and training-set sizes. Furthermore, the framework provides a reliable explanation that considers node features together with the graph structure. We also used the framework to screen 105 potential photovoltaic absorber materials.