Ivan Zorin

Dr. Ivan Zorin

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 December 2020 in Optica
Verified
Journal Article
Closed access
AVAron Vanselow
Aron Vanselow
PKPaul Kaufmann
Paul Kaufmann
IZIvan Zorin
Ivan Zorin
BHBettina Heise
Bettina Heise
HCHelen M. Chrzanowski
Helen M. Chrzanowski
SRSven Ramelow
Sven Ramelow
Mid-infrared (mid-IR) light scatters much less than shorter wavelengths, allowing greatly enhanced penetration depths for optical imaging techniques such as optical coherence tomography (OCT). However, both detection and broadband sources in the mid-IR are technologically challenging. Interfering entangled photons in a nonlinear interferometer enables sensing with undetected photons, making mid-IR sources and detectors obsolete. Here we implement mid-IR frequency-domain OCT based on ultra-broadband entangled photon pairs spanning from 3.3 to 4.3 µm. We demonstrate 10 µm axial and 20 µm lateral resolution 2D and 3D imaging of strongly scattering ceramic and paint samples. By intrinsically being limited only by shot noise, we observe times more sensitivity per integration time and power of the probe light. Together with the vastly reduced footprint and technical complexity, our technique can outperform conventional approaches with classical mid-IR light sources.

3 February 2022 in Optics Express
Verified
Journal Article
Closed access
IZIvan Zorin
Ivan Zorin
PGPaul Gattinger
Paul Gattinger
AEAlexander Ebner
Alexander Ebner
MBMarkus Brandstetter
Markus Brandstetter
Supercontinuum sources are all-fiber pulsed laser-driven systems that provide high power spectral densities within ultra-broadband spectral ranges. The tailored process of generating broadband, bright, and spectrally flat supercontinua—through a complex interplay of linear and non-linear processes—has been recently pushed further towards longer wavelengths and has evolved enough to enter the field of mid-infrared (mid-IR) spectroscopy. In this work, we review the current state and perspectives of this technology that offers laser-like emission properties and instantaneous broadband spectral coverage comparable to thermal emitters. We aim to go beyond a literature review. Thus, we first discuss the basic principles of supercontinuum sources and then provide an experimental part focusing on the quantification and analysis of intrinsic emission properties such as typical power spectral densities, brightness levels, spectral stability, and beam quality (to the best of the authors’ knowledge, the M2 factor for a mid-IR supercontinuum source is characterized for the first time). On this basis, we identify key competitive advantages of these alternative emitters for mid-IR spectroscopy over state-of-the-art technologies such as thermal sources or quantum cascade lasers. The specific features of supercontinuum radiation open up prospects of improving well-established techniques in mid-IR spectroscopy and trigger developments of novel analytical methods and instrumentation. The review concludes with a structured summary of recent advances and applications in various routine mid-IR spectroscopy scenarios that have benefited from the use of supercontinuum sources.

7 December 2018 in Optics Express
Verified
Journal Article
Closed access
PDF file
IZIvan Zorin
Ivan Zorin
RSRong Su
Rong Su
APAndrii Prylepa
Andrii Prylepa
JKJakob Kilgus
Jakob Kilgus
MBMarkus Brandstetter
Markus Brandstetter
BHBettina Heise
Bettina Heise
Optical technology in the mid-infrared wavelength range is currently a rapidly developing field initiated by the availability of novel high-power and spatially coherent sources. Non-destructive testing techniques based on these sources are very promising for industrial and medical applications. However, there are still many engineering problems due to the technical challenges and high prices of the optical elements suitable for the mid-infrared region. In this paper, we report the development and performances of the first mid-infrared Fourier-domain optical coherence tomography based on a supercontinuum source and low-cost pyroelectric detector. The system is designed to operate in the spectral region around 4 μm. Experimental results are demonstrated for detections of embedded microstructures in ceramic materials and subsurface oil paint layers.

7 November 2018 in Optics Express
Verified
Journal Article
Open access
PDF file
JKJakob Kilgus
Jakob Kilgus
GLGregor Langer
Gregor Langer
KDKristina Duswald
Kristina Duswald
Robert ZimmerleiterRobert Zimmerleiter
Robert Zimmerleiter
IZIvan Zorin
Ivan Zorin
MBMarkus Brandstetter
Markus Brandstetter
Chemical mapping was demonstrated with a mid-infrared (MIR) microspectroscopy setup based on a supercontinuum source (SC) emitting in the spectral range from 1.55 to 4.5 µm and a MEMS-based Fabry-Pérot filter spectrometer. Diffraction limited spatial resolution in reflection geometry was achieved. A multilayer film consisting of different polymers and mixtures thereof was measured and results were compared to those gained with a conventional FTIR microscope equipped with a thermal MIR source. Results show that compared to thermal sources, the application of the SC source results in higher signal-to-noise ratios together with better spatial resolution and faster scanning. Furthermore, diffraction limited imaging of red blood cells was demonstrated for the first time in the MIR spectral region in reflection mode. The distinctive characteristics of the MIR spectral region in conjunction with the high brightness, spatial coherence and broadband nature of supercontinuum radiation show the potential for improving infrared microscopy significantly.

19 April 2019 in Optics Express
Verified
Journal Article
Open access
PDF file
PGPaul Gattinger
Paul Gattinger
JKJakob Kilgus
Jakob Kilgus
IZIvan Zorin
Ivan Zorin
GLGregor Langer
Gregor Langer
RNRamin Nikzad-Langerodi
Ramin Nikzad-Langerodi
MBMarkus Brandstetter
Markus Brandstetter
We introduce a compressive sensing based approach for single pixel hyperspectral chemical imaging in a broad spectral range in the near-infrared. Fully integrated MEMS based Fabry-Pérot tunable filter spectrometers and a digital micro-mirror device were employed to achieve spectral and spatial resolution, respectively. The available spectral range from 1500 to 2200 nm covers molecular overtone vibrations enabling chemical identification. Hyperspectral images of different adhesives deposited on a textile were recorded revealing their chemical composition. Furthermore, spectrally resolved near-infrared images with compression rates up to 90% are presented. The approach of single pixel imaging illustrates a promising technology for the infrared spectral range superior to conventionally used costly focal plane arrays.

25 February 2020 in Applied Spectroscopy
Verified
Journal Article
Closed access
PDF file
IZIvan Zorin
Ivan Zorin
JKJakob Kilgus
Jakob Kilgus
KDKristina Duswald
Kristina Duswald
IAInstitute of Chemical Technologies and Analytics
Institute of Chemical Technologies and Analytics
BHBettina Heise
Bettina Heise
MBMarkus Brandstetter
Markus Brandstetter
Fourier transform infrared (FT-IR) spectrometers have been the dominant technology in the field of mid-infrared (mid-IR) spectroscopy for decades. Supercontinuum laser sources operating in the mid-IR spectral region now offer the potential to enrich the field of FT-IR spectroscopy due to their distinctive properties, such as high-brightness, broadband spectral coverage and enhanced stability. In our contribution, we introduce this advanced light source as a replacement for conventional thermal emitters. Furthermore, an approach to efficient coupling of pulsed mid-IR supercontinuum sources to FT-IR spectrometers is proposed and considered in detail. The experimental part is devoted to pulse-to-pulse energy fluctuations of the applied supercontinuum laser, performance of the system, as well as the noise and long-term stability. Comparative measurements performed with a conventional FT-IR instrument equipped with a thermal emitter illustrate that similar noise levels can be achieved with the supercontinuum-based system. The analytical performance of the supercontinuum-based FT-IR spectrometer was tested for a concentration series of aqueous formaldehyde solutions in a liquid flow cell (500 µm path length) and compared with the conventional FT-IR (130 µm path length). The results show a four-times-enhanced detection limit due to the extended path length enabled by the high brightness of the laser. In conclusion, FT-IR spectrometers equipped with novel broadband mid-IR supercontinuum lasers could outperform traditional systems providing superior performance, e.g., interaction path lengths formerly unattainable, while maintaining low noise levels known from highly stable thermal emitters.