Markus Brandstetter

Dr. Markus Brandstetter

orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 August 2017 in Chemical Society Reviews
Verified
Journal Article
Open access
PDF file
ASAndreas Schwaighofer
Andreas Schwaighofer
MBMarkus Brandstetter
Markus Brandstetter
IAInstitute of Chemical Technologies and Analytics
Institute of Chemical Technologies and Analytics
This review focuses on the recent applications of QCLs in mid-IR spectroscopy of clinically relevant samples.

3 February 2022 in Optics Express
Verified
Journal Article
Closed access
IZIvan Zorin
Ivan Zorin
PGPaul Gattinger
Paul Gattinger
AEAlexander Ebner
Alexander Ebner
MBMarkus Brandstetter
Markus Brandstetter
Supercontinuum sources are all-fiber pulsed laser-driven systems that provide high power spectral densities within ultra-broadband spectral ranges. The tailored process of generating broadband, bright, and spectrally flat supercontinua—through a complex interplay of linear and non-linear processes—has been recently pushed further towards longer wavelengths and has evolved enough to enter the field of mid-infrared (mid-IR) spectroscopy. In this work, we review the current state and perspectives of this technology that offers laser-like emission properties and instantaneous broadband spectral coverage comparable to thermal emitters. We aim to go beyond a literature review. Thus, we first discuss the basic principles of supercontinuum sources and then provide an experimental part focusing on the quantification and analysis of intrinsic emission properties such as typical power spectral densities, brightness levels, spectral stability, and beam quality (to the best of the authors’ knowledge, the M2 factor for a mid-IR supercontinuum source is characterized for the first time). On this basis, we identify key competitive advantages of these alternative emitters for mid-IR spectroscopy over state-of-the-art technologies such as thermal sources or quantum cascade lasers. The specific features of supercontinuum radiation open up prospects of improving well-established techniques in mid-IR spectroscopy and trigger developments of novel analytical methods and instrumentation. The review concludes with a structured summary of recent advances and applications in various routine mid-IR spectroscopy scenarios that have benefited from the use of supercontinuum sources.

10 June 2015 in Analytical Chemistry
Verified
Journal Article
Closed access
MAMirta R. Alcaráz
Mirta R. Alcaráz
ASAndreas Schwaighofer
Andreas Schwaighofer
CKChristian Kristament
Christian Kristament
GRGeorg Ramer
Georg Ramer
MBMarkus Brandstetter
Markus Brandstetter
BLBernhard Lendl
Bernhard Lendl

22 June 2012 in Applied Physics B
Verified
Journal Article
Closed access
PDF file
MBMarkus Brandstetter
Markus Brandstetter
LVL. Volgger
L. Volgger
AGA. Genner
A. Genner
CJC. Jungbauer
C. Jungbauer
BLB. Lendl
B. Lendl

7 December 2018 in Optics Express
Verified
Journal Article
Closed access
PDF file
IZIvan Zorin
Ivan Zorin
RSRong Su
Rong Su
APAndrii Prylepa
Andrii Prylepa
JKJakob Kilgus
Jakob Kilgus
MBMarkus Brandstetter
Markus Brandstetter
BHBettina Heise
Bettina Heise
Optical technology in the mid-infrared wavelength range is currently a rapidly developing field initiated by the availability of novel high-power and spatially coherent sources. Non-destructive testing techniques based on these sources are very promising for industrial and medical applications. However, there are still many engineering problems due to the technical challenges and high prices of the optical elements suitable for the mid-infrared region. In this paper, we report the development and performances of the first mid-infrared Fourier-domain optical coherence tomography based on a supercontinuum source and low-cost pyroelectric detector. The system is designed to operate in the spectral region around 4 μm. Experimental results are demonstrated for detections of embedded microstructures in ceramic materials and subsurface oil paint layers.

7 November 2018 in Optics Express
Verified
Journal Article
Open access
PDF file
JKJakob Kilgus
Jakob Kilgus
GLGregor Langer
Gregor Langer
KDKristina Duswald
Kristina Duswald
Robert ZimmerleiterRobert Zimmerleiter
Robert Zimmerleiter
IZIvan Zorin
Ivan Zorin
MBMarkus Brandstetter
Markus Brandstetter
Chemical mapping was demonstrated with a mid-infrared (MIR) microspectroscopy setup based on a supercontinuum source (SC) emitting in the spectral range from 1.55 to 4.5 µm and a MEMS-based Fabry-Pérot filter spectrometer. Diffraction limited spatial resolution in reflection geometry was achieved. A multilayer film consisting of different polymers and mixtures thereof was measured and results were compared to those gained with a conventional FTIR microscope equipped with a thermal MIR source. Results show that compared to thermal sources, the application of the SC source results in higher signal-to-noise ratios together with better spatial resolution and faster scanning. Furthermore, diffraction limited imaging of red blood cells was demonstrated for the first time in the MIR spectral region in reflection mode. The distinctive characteristics of the MIR spectral region in conjunction with the high brightness, spatial coherence and broadband nature of supercontinuum radiation show the potential for improving infrared microscopy significantly.