Adopting proton exchange membrane fuel cells fuelled by hydrogen presents a promising solution for the shipping industry’s deep decarbonisation. However, the potential safety risks associated with hydrogen leakage pose a significant challenge to the development of hydrogen-powered ships. This study examines the safe design principles and leakage risks of the hydrogen gas supply system of China’s first newbuilt hydrogen-powered ship. This study utilises the computational fluid dynamics tool FLACS to analyse the hydrogen dispersion behaviour and concentration distributions in the hydrogen fuel cell room based on the ship’s parameters. This study predicts the flammable gas cloud and time points when gas monitoring points first reach the hydrogen volume concentrations of 0.8% and 1.6% in various leakage scenarios, including four different diameters (1, 3, 5, and 10 mm) and five different directions. This study’s findings indicate that smaller hydrogen pipeline diameters contribute to increased hydrogen safety. Specifically, in the hydrogen fuel cell room, a single-point leakage in a hydrogen pipeline with an inner diameter not exceeding 3 mm eliminates the possibility of flammable gas cloud explosions. Following a 10 mm leakage diameter, the hydrogen concentration in nearly all room positions reaches 4.0% within 6 s of leakage. While the leakage diameter does not impact the location of the monitoring point that first activates the hydrogen leak alarm and triggers an emergency hydrogen supply shutdown, the presence of obstructions near hydrogen detectors and the leakage direction can affect it. These insights provide guidance on the optimal locations for hydrogen detectors in the fuel cell room and the pipeline diameters on hydrogen gas supply systems, which can facilitate the safe design of hydrogen-powered ships.
In order to ensure the safety of shore-based hydrogen bunkering operations, this paper takes a 2000-ton bulk hydrogen powered ship as an example. Firstly, the HAZID method is used to identify the hazards of hydrogen bunkering, then the probability of each scenario is analyzed, and then the consequences of scenarios with high risk based on FLACS software is simulated. Finally, the personal risk of bunkering operation is evaluated and the bunkering restriction area is defined. The results show that the personal risk of shore-based bunkering operation of hydrogen powered ship is acceptable, but the following risk control measures should be taken: (1) The bunkering restriction area shall be delineated, and only the necessary operators are allowed to enter the area and control the any form of potential ignition source; (2) The hose is the high risk hazards during bunkering. The design form of bunkering arm and bunkering hose is considered to shorten the length of the hose as far as possible; (3) A safe distance between shore-based hydrogenation station and the building outside the station should be guaranteed. The results have a guiding role in effectively reducing the risk of hydrogen bunkering operation.
Leakage incidents on LNG bunker vessels will result in a serious degree of hazard. This paper investigates typical high-risk scenarios such as hose ruptures and valve joint leakages. The consequences of an LNG leakage accident during the simultaneous operation of a bunker vessel and a container carrier are simulated using the FLACS software, and the dispersion range of the combustible vapor cloud is quantitatively analyzed under both ballast and laden conditions. Under the ballast condition, the diffusion range of the combustible vapor cloud on the side of the bunker vessel is 58 × 15.5 m from the front wall of the cargo equipment room to the bow of the vessel, and 35 × 9.5 m between the cargo equipment room and the transom of the vessel. Under the laden condition, the diffusion range on the side of the bunker vessel is 58 × 15.5 m from the front wall of the cargo equipment room to the bow of the vessel, and 15 × 4 m between the rear end wall of the cargo equipment room and the front wall of the stern of the vessel. These results provide important technical guidance and reference values for the safe operation of LNG bunker vessels.