Wenling Jiao

Dr. Wenling Jiao


Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 December 2014 in Energies
Verified
Journal Article
Open access
PDF file
HWHaichao Wang
Haichao Wang
WJWenling Jiao
Wenling Jiao
RLRisto Lahdelma
Risto Lahdelma
CZChuanzhi Zhu
Chuanzhi Zhu
PZPinghua Zou
Pinghua Zou
Combined heat and power (CHP) is a promising technology that can contribute to energy efficiency and environmental protection. More CHP-based energy systems are planned for the future. This makes the evaluation and selection of CHP systems very important. In this paper, 16 CHP units representing different technologies are taken into account for multicriteria evaluation with respect to the end users’ requirements. These CHP technologies cover a wide range of power outputs and fuel types. They are evaluated from the energy, economy and environment (3E) points of view, specifically including the criteria of efficiency, investment cost, electricity cost, heat cost, CO2 production and footprint. Uncertainties and imprecision are common both in criteria measurements and weights, therefore the stochastic multicriteria acceptability analysis (SMAA) model is used in aiding this decision making problem. These uncertainties are treated better using a probability distribution function and Monte Carlo simulation in the model. Moreover, the idea of “feasible weight space (FWS)” which represents the union of all preference information from decision makers (DMs) is proposed. A complementary judgment matrix (CJM) is introduced to determine the FWS. It can be found that the idea of FWS plus CJM is well compatible with SMAA and thus make the evaluation reliable.

29 July 2022 in Journal of Civil Structural Health Monitoring
Verified
Journal Article
Closed access
PDF file
XTXinghao Tian
Xinghao Tian
WJWenling Jiao
Wenling Jiao
TLTianjie Liu
Tianjie Liu

10 June 2023 in Energies
Verified
Journal Article
Open access
PDF file
XKXiangyu Kong
Xiangyu Kong
WJWenling Jiao
Wenling Jiao
WXWeidong Xiang
Weidong Xiang
QWQiang Wang
Qiang Wang
JCJiaolong Cao
Jiaolong Cao
LHLianfu Han
Lianfu Han
Leakage incidents on LNG bunker vessels will result in a serious degree of hazard. This paper investigates typical high-risk scenarios such as hose ruptures and valve joint leakages. The consequences of an LNG leakage accident during the simultaneous operation of a bunker vessel and a container carrier are simulated using the FLACS software, and the dispersion range of the combustible vapor cloud is quantitatively analyzed under both ballast and laden conditions. Under the ballast condition, the diffusion range of the combustible vapor cloud on the side of the bunker vessel is 58 × 15.5 m from the front wall of the cargo equipment room to the bow of the vessel, and 35 × 9.5 m between the cargo equipment room and the transom of the vessel. Under the laden condition, the diffusion range on the side of the bunker vessel is 58 × 15.5 m from the front wall of the cargo equipment room to the bow of the vessel, and 15 × 4 m between the rear end wall of the cargo equipment room and the front wall of the stern of the vessel. These results provide important technical guidance and reference values for the safe operation of LNG bunker vessels.

9 December 2022 in Energy Science & Engineering
Verified
Journal Article
Open access
TLTianjie Liu
Tianjie Liu
WJWenling Jiao
Wenling Jiao
XTXinghao Tian
Xinghao Tian
XZXin Zhang
Xin Zhang
In the process of the district energy system (DES) operation and dispatching, there are various uncertainties brought by the strong coupling of equipment and the fluctuation of internal and external surroundings, and these uncertain parameters are often correlated. In this paper, an improved affine arithmetic‐based method is proposed to solve the economic dispatching problem of DES with correlated uncertainties. First, an optimal dispatching model considering economic and environmental factors is constructed. An affine algorithm is introduced and interval arithmetic is used to improve the problem of interval extension and high‐order noise element. Taking a classical DES system as an example, the optimal dispatching of the system is analyzed using deterministic method, interval method, and proposed method. The application effect of the proposed method under different uncertainties scale and amplitude is also discussed. The results show that the proposed method can effectively reduce the width of target value interval compared with the traditional interval optimization method, which can further contribute to the optimal operation decision.

22 October 2025 in Scientific Reports
Verified
Journal Article
Open access
PDF file
TLTianjie Liu
Tianjie Liu
WJWenling Jiao
Wenling Jiao
ZHZhiwei Huang
Zhiwei Huang
JYJianting Yu
Jianting Yu
XZXin Zhang
Xin Zhang
LLLuling Li
Luling Li
Accurate short-term air conditioning load forecasting is very important for controlling air conditioning energy consumption, and is also a requisite for realizing intelligent control of air conditioning units. This paper proposes a short-term load forecasting framework for air conditioning based on the concept of model stacking, which combines six mature machine learning models, including Lasso regression, Ridge regression, Random Forest, Support Vector Regression, eXtreme Gradient Boosting and Long Short-Term Memory, and trains new prediction models through model stacking. In order to realize the short term forecast function of air conditioning load, this paper presents a complete forecast framework, which includes operational procedures for feature screening, algorithm hyperparameters optimization, and cross stacking of prediction models. A real air conditioning system is employed for prediction analysis, the prediction results showed that 28 out of 36 control simulations achieved better prediction accuracy, with an average increase in R2 of 6.4%. Notably, simpler submodels in the meta-model yield better results in model stacking, whereas complex coupling models as the meta-model may degrade performance. The proposed framework not only improves prediction accuracy but also maintains reasonable training time and resource requirements, making it practical for real-world applications. These findings provide insights into implementation of model stacking and selecting the meta-model for short-term air conditioning load forecasting.

30 November 2022 in Energy Reports
Verified
Journal Article
Open access
TLTianjie Liu
Tianjie Liu
WJWenling Jiao
Wenling Jiao
XTXinghao Tian
Xinghao Tian
XZXin Zhang
Xin Zhang
According to the energy consumption characteristics of gas stations, the district energy system (DES) based on natural gas and renewable energy is a suitable form of energy supply. In the process of DES operation and dispatching, there are various uncertainties brought by the strong coupling of equipment and the fluctuation of internal and external surroundings, and these uncertain parameters are often correlated. In this paper, an improved affine arithmetic (AA) based method is proposed to solve the economic dispatching problem of DES with correlated uncertainties. Firstly, an optimal dispatching model considering economic and environmental factors is constructed. An affine algorithm is introduced and interval arithmetic (IA) is used to improve the problem of interval extension and high-order noise element. Taking a classical DES system as an example, the optimal dispatching of the system is analyzed using deterministic method, interval method and the proposed method. The application effect of the proposed method under different uncertainties scale and amplitude is also discussed. The calculation results in different scenarios show that compared with the traditional IA method, the proposed method can effectively reduce the width of the target value interval by about 13%, which can further contribute to the optimal operation decision.