An inducer is a key component in a cryogenic pump to improve its cavitation performance. The thermodynamic effects of the cryogenic medium make the cryogenic cavitation flow extremely complicated. For this reason, it is crucial to investigate the cryogenic cavitation flow of the inducer which is equipped upstream of the cryogenic pump. In this paper, the isothermal cavitation model is modified based on the law of heat conduction, and the cryogenic cavitation model of the inducer is developed by considering thermodynamic effects. The turbulence model is also modified to account for the compressibility of cryogenic cavitation flow. The methods of numerical calculations are performed to investigate the influence of thermodynamic effects on cryogenic cavitation of the inducer. The law of the spatio-temporal evolution of cryogen cavitation in the inducer is clarified. The initial position, development and collapse phenomenon of cavitation are obtained. The relationship between the generation and collapse of the cavitation and the work capacity of the inducer’s blade, the relationship between thermodynamic effects and the influence of the inducer’s blade tip leakage vortex and thermodynamic on cryogenic cavitation of the inducer are revealed.
The influence mechanism of the blade tip clearance (TC) of an inducer on the performance of a centrifugal pump at high speed was researched under different flow rate conditions in this work. An experiment on the pump’s external performance was carried out, and numerical calculation was also performed under four different TCs. The full characteristic performance curves, static pressure and pressure pulsation distributions of the pump were obtained. Through the research and analysis, it was found that the influence of the TC on the efficiency and the head of the centrifugal pump are related to the flow rate. Under the influence of a large flow rate, the increase in the TC is helpful to improve the efficiency and the head of the pump. The increase in the TC helps to weaken the gap jet effect on the inducer. The inlet jet of the inducer, caused by TC leakage, will form a low-pressure vortex zone at the inlet of the inducer. The splitter-bladed inducer’s pressure pulsation is affected by the TC. The peak pressure pulsation at the monitoring point at the short blades is larger than that at the long blades. With the increase in TC, the cavitation degree at the inlet of the long blade of the inducer is decreased, while the cavitation degree at the short blade is deepened. It is also found that the TC has little effect on the radial force of the inducer and the impeller. These results will provide the design basis for the tip clearance of an inducer.
V-port ball valves have been widely utilized as a control device in various fluid transmission systems, achieving the function of throttling and controlling the flow direction effectively. However, the flow characteristics for a V-port ball valve in the opening and closing processes are unclear, especially the influence of different cone angles on the valve regulation process. The present work investigates the transient regulation performance and internal flow characteristics with different cone angles of a V-port ball valve in its opening and closing processes experimentally and numerically. The results reveal that the performance parameters involving the flow rate, pressure, and flow coefficient in the opening process are greater than those in the closing process; subsequently, they become the same after stabilization. The V-port cone angle affects the flow rate, pressure, and flow coefficient significantly. The maximum flow rate and flow coefficient increases with the increase in the cone angle. The inlet pressure and the initial opening in which the outlet pressure begins to reduce decrease with an increase in the cone angle. In the valve regulation process, the interaction between the flow and the cone leading edge produces a large flow variation. As the cone angle increases, the variation degree at the leading edge weakens. The current conclusions can provide a reference for the design and optimization of V-port ball valves.
For a high-speed centrifugal pump, cavitation occurs easily. To equip a high-performance splitter-bladed inducer upstream of the pump is an effective method to suppress cavitation. In this paper, an external characteristics experiment of the high-speed centrifugal pump with a splitter-bladed inducer is carried out, and the corresponding numerical calculations are completed. The research shows that the results of the numerical calculation are credible. Numerical cavitation calculations under eight different tip clearance conditions are carried out. First, it is found that the tip clearance (TC) has a certain impact on the head of the centrifugal pump. When TC is in a small range, the clearance leakage is small, and the impact on the head of the pump is not so obvious, which can give the pump a higher performance. Second, it is found that TC has a certain influence on the static pressure distribution in the cascade passage of the splitter-bladed inducer. When TC is in a certain range, the increasement in TC will aggravate the cavitation at the suction surface of the long blades near the inlet. When it exceeds the certain range, it will cause cavitation at the outlet of the inducer. At last, it is found that the cavitation’s severity and position of the inducer are closely related to TC. TC affects the magnitude and position of vorticity in the inducer’s passage. In this paper the flow mechanism of TC is revealed, and its research results can provide theoretical basis and technical support for the design of the tip clearance of the inducers.
8 July 2024 in International Journal of Fluid Engineering
Accurate prediction of the impact of flow maldistribution on the thermo-hydraulic behavior of plate heat exchangers is important for thermal design and optimization in a number of practical applications. In this paper, a coupled modeling framework, consisting of a heat transfer model and a hydraulic model, is proposed for quantitatively evaluating the impact of maldistribution on the thermo-hydraulic performance of a cross-flow-corrugated plate heat exchanger. The numerical results of the proposed approach are validated by comparison with experimental data. Using the coupled model, the flow distribution nonuniformity, heat exchanger effectiveness deteriorations, and pressure drop deviations are analyzed. Furthermore, the combined effects of side stream maldistribution are investigated for different inlet Reynolds numbers and inlet temperatures. The results demonstrate that when the inlet gas Reynolds number is in the range of 1100–2700, nonuniform distribution of the gas side will cause air maldistribution, and a 10%–30% effectiveness deterioration rate. It is found that air maldistribution will not result in gas maldistribution when the inlet air Reynolds number is in the range of 6000–18 000, but increasing air nonuniformity. Will lead to increasing deterioration in heat exchanger effectiveness. In the presence of air and gas flow maldistribution, the pressure drops on the gas and air sides increase by 5% and less than 12.4%, respectively. This work provides a computational framework for optimization of cross-flow-corrugated plate heat exchangers to achieve desired thermo-hydraulic performance.
In order to study the effect of tip clearance on the internal cavitation stability of a shunt blade inducer, an external characteristics experiment of a centrifugal pump with a shunt blade inducer was carried out. Based on the turbulence model and mixture model, the cavitating flow in a centrifugal pump with the inducer was numerically simulated. The influence of tip clearance on the cavitating flow in a shunt inducer was studied and analyzed. Through the research, it was found that tip clearance has a certain influence on the critical cavitation coefficient. The existence of the tip clearance caused a significant leakage vortex near the inducer’s inlet and a strong transient effect was shown. The location and degree of cavitation caused by the tip leakage are clarified in this paper. Tip clearance has a great impact on the pressure distribution on a shunt blade inducer. The influence law of tip clearance on an inducer’s blade load distribution was clarified. The results showed that tip clearance has a significant effect on the cavitation of a shunt blade inducer under low flow rate conditions.