Wojciech Rzeźnik

Dr. Wojciech Rzeźnik

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 October 2021 in Atmosphere
Verified
Journal Article
Open access
PDF file
PMPaulina Mielcarek-Bocheńska
Paulina Mielcarek-Bocheńska
WRWojciech Rzeźnik
Wojciech Rzeźnik
Agriculture is one of the main sources of greenhouse gas (GHG) emissions and has great potential for mitigating climate change. The aim of this study is to analyze the amount, dynamics of changes, and structure of GHG emissions from agriculture in the EU in the years 2005–2018. The research based on data about GHG collected by the European Environment Agency. The structure of GHG emissions in 2018 in the EU is as follows: enteric fermentation (45%), agricultural soils (37.8%), manure management (14.7%), liming (1.4%), urea application (1%), and field burning of agricultural residues (0.1%). Comparing 2018 with the base year, 2005, emissions from the agricultural sector decreased by about 2%, which is less than the assumed 10% reduction of GHG emissions in the non-emissions trading system (non-ETS) sector. The ambitious goals set by the EU for 2030 assume a 30% reduction in the non-ETS sector. This will require a significant reduction in GHG emissions from agriculture. Based on the analysis of the GHG emission structure and available reduction techniques, it was calculated that in this period, it should be possible to reduce emissions from agriculture by about 15%.

1 February 2022 in Atmosphere
Verified
Journal Article
Open access
PDF file
WRWojciech Rzeźnik
Wojciech Rzeźnik
PMPaulina Mielcarek-Bocheńska
Paulina Mielcarek-Bocheńska
Due to the intensification and concentration of agriculture and the interpenetration of residential and agricultural areas, odours are an important air pollutant. The changes taking place in rural areas mean that not all inhabitants of these areas are involved in agricultural activities, and there are new people looking for an idyllic life in the countryside. In recent years, there has been an increase in the number of complaints concerning odour emissions from agricultural sources. The aim of the study was to compare odour emissions from selected livestock buildings for various animal species in the Great Poland Voivodeship. The assessment of odour concentrations was made in accordance with EN 13725: 2003 using the TO 8 olfactometer in the accredited olfactometric laboratory of the Institute of Technology and Life Sciences National Research Institute in Poznań. The fattening house showed the highest odour burden for the surroundings (mean odour concentration and odour emission factor: 450 ouE·m3 and 0.419 ouE·s−1·kg−1, respectively). In the case of buildings for poultry and dairy cows, the differences in the emission factors were not large. The emission factor for poultry (0.232 ouE·s−1·kg−1) was 22% higher than that for dairy cows (0.190 ouE·s−1·kg−1). Conversely, the mean concentration in the hen house (281 ouE·m3) was 18% lower than that in the dairy cow barn (342 ouE·m3).

18 September 2023 in Energies
Verified
Journal Article
Open access
PDF file
WRWojciech Rzeźnik
Wojciech Rzeźnik
IRIlona Rzeźnik
Ilona Rzeźnik
PMPaulina Mielcarek-Bocheńska
Paulina Mielcarek-Bocheńska
MUMateusz Urbański
Mateusz Urbański
One of the aims of the environmental and energy policy of the European Union is to reduce the emission of air pollutants, primarily from heat and electricity production, e.g., using renewable energy sources. An example of such a fuel is agricultural biomass including animal manure, which can be used to produce energy in many ways, inter alia direct combustion. The aim of the study was to measure the concentration of NO, NOx, CO, dust and boiler efficiency during the combustion and co-combustion of wood and manure pellets. The research was conducted in the laboratory of the Poznań University of Technology using a 15 kW domestic boiler at maximum power. Manure pellets had higher moisture—9.2%, lower high heating value—17.25 MJ·kg−1, lower low heating value—16.45 MJ·kg−1, and higher ash content—11.23% than wood pellets. The average concentrations of CO, NO, NOx and dust for 100% wood pellets were 198 ± 27 mg·m−3, 129 ± 5 mg·m−3, 198 ± 8 mg·m−3 and 8.7 ± 0.5 mg·m−3, respectively. For this, the fuel boiler power was 13.6 kW (air–fuel ratio 1.48), and it was close to the maximal nominal power. Increasing the share of manure pellets in the burning mixture worsened the stability of the combustion process, and the occurrence of incomplete combustion was observed, which resulted in an increased concentration of CO and dust. Additionally, NO and NOx concentrations also increased. The average boiler power during the combustion of 100% manure pellets was 7.8 kW (air–fuel ratio 2.2), and the average concentrations of CO, NO, NOx and dust were 1548 ± 555 mg·m−3, 355 ± 53 mg·m−3, 554 ± 88 mg·m−3 and 482 ± 63 mg·m−3, respectively.

20 September 2022 in Energies
Verified
Journal Article
Open access
PDF file
WRWojciech Rzeźnik
Wojciech Rzeźnik
IRIlona Rzeźnik
Ilona Rzeźnik
PHPaweł Hara
Paweł Hara
Determining the demand for heat power for domestic hot water preparation is necessary to perform a building energy assessment. For this, we need to predict domestic hot water consumption. Considering the number of factors influencing domestic hot water consumption, it is difficult to develop a highly accurate methodology. The aim of the study was to compare the real domestic hot water consumption and heat power for its preparation with the values calculated based on the available prediction methods in multi-family buildings. The analysis was carried out based on annual monitoring (2021 year) of domestic hot water consumption and the actual demand for heat power in eight multi-family buildings located in Grudziądz, in Central Poland. The results of these measurements were compared with the values determined based on the available methodologies for forecasting the demand for heat power and domestic hot water consumption: Sander’s, Recknagel’s, the standard method and the method according to Polish regulations from 2008 and 2015. The real average demand for heat power for domestic hot water was 89.8 ± 8.5 W/person, 211.2 ± 13.7 W/apartment and 4.8 ± 0.3 W/m2, and the daily domestic hot water consumption was 26.7 ± 3.6 dm3/person·day, 62.6 ± 5.8 dm3/apartment·day and 1.4 ± 0.1 dm3/m2·day. The real demand for heat power for domestic hot water was lower than that determined by the analyzed methods. The values obtained from the modified standard method based on Standard PN-92/B-01706/A1: 1999, with mean relative error of 10.5 ± 4.1%, were the closest to the real values. The current ordinance method (Regulation 2015) is characterized by an error of 45.4 ± 10.2%. The predicted domestic hot water consumption using the current ordinance was the closest to the real consumption. On average, it was higher by 7.7 ± 5.0%.

16 January 2020 in Polish Journal of Environmental Studies
Verified
Journal Article
Closed access
WRWojciech Rzeźnik
Wojciech Rzeźnik
PMPaulina Mielcarek-Bocheńska
Paulina Mielcarek-Bocheńska
The sustainable intensification of agriculture needs the use of natural fertilizers. Odour emission from their application is bothersome for the surroundings – especially in suburban areas. The aim of the study was to compare odour concentrations after pig slurry application using two different types of applicators. Odour measurements were carried out on two experimental fields where the pig slurry was applied by different methods. On field I it was a trailing hose applicator (Zunhammer SKE 15,5), and on field II it was a conventional splash-plate applicator (Joskin Modulo 2 8400 with a so-called ‘Exact’ scatterer). Measurements included 6 series in the following periods: immediately after application and 1, 2, 3, 4 and 5 hours after application. Odour analysis was made within 30h of collection using the dynamic olfactometry method (ECOMA TO 8 olfactometer) according to the Standard PN-EN 13725:2007. The average value of odour concentration was 683 ouE·m-3 for a trailing hose applicator and 522 ouE·m-3 for conventional splash-plate applicator. Three hours after application of pig slurry, the odour concentrations on two experimental fields were relatively low and almost did not differ between each other. Use of the trailing hose applicator for pig slurry application resulted in 31% higher odour emissions than slurry spreading by conventional splash-plate applicator. The biggest difference between odour concentration was immediately after application (56%) and it decreased to almost 0% (3 hours after application). The largest decrease in odour concentration, by nearly 50% for both fields, was observed during the first hour after slurry application.

1 December 2019 in Ecological Chemistry and Engineering S
Verified
Journal Article
Open access
PDF file
PMPaulina Mielcarek-Bocheńska
Paulina Mielcarek-Bocheńska
WRWojciech Rzeźnik
Wojciech Rzeźnik
The aim of this study was to examine the impact of inside temperature and relative humidity, ventilation rate and gas concentrations (NH3, N2O, CO2) on odour emissions from deep-litter piggery. The studied facility had temperature-controlled mechanical ventilation. The measurements were conducted from March to June 2014. During the research, selected microclimate parameters, as well as number and mass of animals were monitored and air samples were collected (two samples of air in each series of measurements). Temperature and relative humidity were measured using Testo 435-4 multifunctional measuring instrument. To measurements of gas concentrations was used the photo-acoustic spectrometer Multi Gas Monitor Model 1312. The concentration of odours in the air samples was determined by dynamic olfactometry with the TO 8 olfactometer, according to PN-EN 13725:2007. The odour concentration ranged from 450 to 2004 ouE · m–3 (mean 1048 ouE · m–3) and the mean odour emission factor was from 5.76 to 46.79 ouE · (s · pig)−1 (mean 20.93 ouE· (s · pig)−1.The statistical analysis showed that the inside temperature explained most of the variability of the odour concentration and the relationship was described by equation: cod = 5634 – 197 Tinside (R2 = 0.82, p ≤ 0.05). For odour emission factor, two parameters: the inside temperature and ventilation rate, explained most of the variability, according to the equation: EFod = 108 + 1939 VR – 5.5 Tinside (R2 = 0.81, p ≤ 0.05).