Ilona Rzeźnik

Dr. Ilona Rzeźnik


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 September 2022 in Energies
Verified
Journal Article
Open access
PDF file
WRWojciech Rzeźnik
Wojciech Rzeźnik
IRIlona Rzeźnik
Ilona Rzeźnik
PHPaweł Hara
Paweł Hara
Determining the demand for heat power for domestic hot water preparation is necessary to perform a building energy assessment. For this, we need to predict domestic hot water consumption. Considering the number of factors influencing domestic hot water consumption, it is difficult to develop a highly accurate methodology. The aim of the study was to compare the real domestic hot water consumption and heat power for its preparation with the values calculated based on the available prediction methods in multi-family buildings. The analysis was carried out based on annual monitoring (2021 year) of domestic hot water consumption and the actual demand for heat power in eight multi-family buildings located in Grudziądz, in Central Poland. The results of these measurements were compared with the values determined based on the available methodologies for forecasting the demand for heat power and domestic hot water consumption: Sander’s, Recknagel’s, the standard method and the method according to Polish regulations from 2008 and 2015. The real average demand for heat power for domestic hot water was 89.8 ± 8.5 W/person, 211.2 ± 13.7 W/apartment and 4.8 ± 0.3 W/m2, and the daily domestic hot water consumption was 26.7 ± 3.6 dm3/person·day, 62.6 ± 5.8 dm3/apartment·day and 1.4 ± 0.1 dm3/m2·day. The real demand for heat power for domestic hot water was lower than that determined by the analyzed methods. The values obtained from the modified standard method based on Standard PN-92/B-01706/A1: 1999, with mean relative error of 10.5 ± 4.1%, were the closest to the real values. The current ordinance method (Regulation 2015) is characterized by an error of 45.4 ± 10.2%. The predicted domestic hot water consumption using the current ordinance was the closest to the real consumption. On average, it was higher by 7.7 ± 5.0%.

18 September 2023 in Energies
Verified
Journal Article
Open access
PDF file
WRWojciech Rzeźnik
Wojciech Rzeźnik
IRIlona Rzeźnik
Ilona Rzeźnik
PMPaulina Mielcarek-Bocheńska
Paulina Mielcarek-Bocheńska
MUMateusz Urbański
Mateusz Urbański
One of the aims of the environmental and energy policy of the European Union is to reduce the emission of air pollutants, primarily from heat and electricity production, e.g., using renewable energy sources. An example of such a fuel is agricultural biomass including animal manure, which can be used to produce energy in many ways, inter alia direct combustion. The aim of the study was to measure the concentration of NO, NOx, CO, dust and boiler efficiency during the combustion and co-combustion of wood and manure pellets. The research was conducted in the laboratory of the Poznań University of Technology using a 15 kW domestic boiler at maximum power. Manure pellets had higher moisture—9.2%, lower high heating value—17.25 MJ·kg−1, lower low heating value—16.45 MJ·kg−1, and higher ash content—11.23% than wood pellets. The average concentrations of CO, NO, NOx and dust for 100% wood pellets were 198 ± 27 mg·m−3, 129 ± 5 mg·m−3, 198 ± 8 mg·m−3 and 8.7 ± 0.5 mg·m−3, respectively. For this, the fuel boiler power was 13.6 kW (air–fuel ratio 1.48), and it was close to the maximal nominal power. Increasing the share of manure pellets in the burning mixture worsened the stability of the combustion process, and the occurrence of incomplete combustion was observed, which resulted in an increased concentration of CO and dust. Additionally, NO and NOx concentrations also increased. The average boiler power during the combustion of 100% manure pellets was 7.8 kW (air–fuel ratio 2.2), and the average concentrations of CO, NO, NOx and dust were 1548 ± 555 mg·m−3, 355 ± 53 mg·m−3, 554 ± 88 mg·m−3 and 482 ± 63 mg·m−3, respectively.

7 November 2017 in E3S Web of Conferences
Verified
Conference Paper
Open access
PDF file
IRIlona Rzeźnik
Ilona Rzeźnik
The air relative humidity in closed spaces of indoor swimming pools influences significantly on users thermal comfort and the stability of the building structure, so its preservation on suitable level is very important. For this purpose, buildings are equipped with HVAC systems which provide adequate level of humidity. The selection of devices and their technical parameters is made using the mathematical models of water evaporation rate in the unoccupied and occupied indoor swimming pool. In the literature, there are many papers describing this phenomena but the results differ from each other. The aim of the study was the experimental verification of published models of evaporation rate in the pool. The tests carried out on a laboratory scale, using model of indoor swimming pool, measuring 99cm/68cm/22cm. The model was equipped with water spray installation with six nozzles to simulate conditions during the use of the swimming pool. The measurements were made for conditions of sports pools (water temperature 24°C) and recreational swimming pool (water temperature 34°C). According to the recommendations the air temperature was about 2°C higher than water temperature, and the relative humidity ranged from 40% to 55%. Models Shah and Biasin & Krumm were characterized by the best fit to the results of measurements on a laboratory scale.

3 July 2018
Verified
Conference Paper
Open access
IRIlona Rzeźnik
Ilona Rzeźnik
The results of experimental investigation of determining the time of temperature drop in domestic hot water circuit were presented in this paper on the example of single-family house. The test were carried out on vertical sections of installations made of PE-X/Al/PE pipes (cross-linked polyethylene and aluminum) with and without insulation. The temperature drop process was investigated in temperature range typical for domestic hot water installation from 55ºC to 40ºC. On the basis of the obtained results with appropriate adjustment of the working time of circulation pump, energy savings of 90% were achieved.