Yeji Hwang

Ms. Yeji Hwang


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 February 2020 in IEEE Robotics and Automation Letters
Verified
Journal Article
Closed access
YHYeji Hwang
Yeji Hwang
SLSeongpung Lee
Seongpung Lee
Jaesung HongJaesung Hong
Jaesung Hong
JKJonghyun Kim
Jonghyun Kim
End-effector type robots have been popularly applied to robot-aided therapy for rehabilitation purpose. However, those robots have a key drawback for the purpose: lack of the user's posture (joint angle) information. This paper proposes a novel end-effector rehabilitation robot system that contains a contactless motion sensor to monitor upper- extremity posture during robot-aided reaching exercise. The sensor allows the posture estimation without complicated procedures but has an inaccuracy problem such as occlusion and an unreliable segment length. Therefore, we developed a posture monitoring method, which is an analytical method without training procedure, based on the combined use of the information obtained from the sensor and the robot. Eight healthy subjects participated in the experiment with planar reaching exercise for validation. The results of joint angle estimation, high correlation coefficient (about 0.95) and small errors (about 3.55 degree), show that the proposed system can provide affordable upper-extremity posture estimation.

3 September 2021 in Sensors
Verified
Journal Article
Open access
PDF file
SLSeunghee Lee
Seunghee Lee
YHYeji Hwang
Yeji Hwang
HLHwang-Jae Lee
Hwang-Jae Lee
YKYun-Hee Kim
Yun-Hee Kim
MOMatjaž Ogrinc
Matjaž Ogrinc
JKJonghyun Kim
Jonghyun Kim
In rehabilitation, the Fugl–Meyer assessment (FMA) is a typical clinical instrument to assess upper-extremity motor function of stroke patients, but it cannot measure fine changes of motor function (both in recovery and deterioration) due to its limited sensitivity. This paper introduces a sensor-based automated FMA system that addresses this limitation with a continuous rating algorithm. The system consists of a depth sensor (Kinect V2) and an algorithm to rate the continuous FM scale based on fuzzy inference. Using a binary logic based classification method developed from a linguistic scoring guideline of FMA, we designed fuzzy input/output variables, fuzzy rules, membership functions, and a defuzzification method for several representative FMA tests. A pilot trial with nine stroke patients was performed to test the feasibility of the proposed approach. The continuous FM scale from the proposed algorithm exhibited a high correlation with the clinician rated scores and the results showed the possibility of more sensitive upper-extremity motor function assessment.