Rupak Dua

Dr. Rupak Dua

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 November 2021 in Polymers
Verified
Journal Article
Open access
PDF file
RDRupak Dua
Rupak Dua
ZRZuri Rashad
Zuri Rashad
JSJoy Spears
Joy Spears
GDGrace Elisabeth Dunn
Grace Elisabeth Dunn
MMMicaela Maxwell
Micaela Maxwell
Polyether ether ketone (PEEK) is an organic polymer that has excellent mechanical, chemical properties and can be additively manufactured (3D-printed) with ease. The use of 3D-printed PEEK has been growing in many fields. This article systematically reviews the current status of 3D-printed PEEK that has been used in various areas, including medical, chemical, aerospace, and electronics. A search of the use of 3D-printed PEEK articles published until September 2021 in various fields was performed using various databases. After reviewing the articles, and those which matched the inclusion criteria set for this systematic review, we found that the printing of PEEK is mainly performed by fused filament fabrication (FFF) or fused deposition modeling (FDM) printers. Based on the results of this systematic review, it was concluded that PEEK is a versatile material, and 3D-printed PEEK is finding applications in numerous industries. However, most of the applications are still in the research phase. Still, given how the research on PEEK is progressing and its additive manufacturing, it will soon be commercialized for many applications in numerous industries.

25 November 2020 in Journal of Biomedical Materials Research Part B: Applied Biomaterials
Verified
Journal Article
Closed access
PDF file
DEDrew T. Elliott
Drew T. Elliott
RWRussell J. Wiggins
Russell J. Wiggins
RDRupak Dua
Rupak Dua

19 December 2023 in Journal of Dental Sciences
Verified
Journal Article
Open access
AAArefin Alam
Arefin Alam
Monica YamautiMonica Yamauti
Monica Yamauti
ACAbu Faem Mohammad Almas Chowdhury
Abu Faem Mohammad Almas Chowdhury
XWXiaohong Wang
Xiaohong Wang
PÁPedro Álvarez-Lloret
Pedro Álvarez-Lloret
HSHidehiko Sano
Hidehiko Sano
The dental adhesive market is constantly evolving to meet the demands of dentists and patients, but new products and upgrades should be rigorously evaluated before being used in clinical practice. This study investigated the physicomechanical properties and dentin bonding efficacy of a newly upgraded universal adhesive compared to its predecessor. Twenty-four molars were divided into four groups (n = 6/group) based on adhesive (new vs. predecessor) and application mode [self-etch (SE) vs. etch-and-rinse (ER)] for evaluating their dentin microtensile bond strength (μTBS), failure pattern, and bonding interface. Additional thirty-six molars’ crowns were perpendicularly sectioned to obtain flat mid-coronal dentin discs. The opposing dentin surfaces of each disc received contrasting treatments (new/predecessor adhesive applied in SE/ER mode), resulting in six interventions. The bonded discs (n = 6/intervention) were used to assess the adhesives’ survival probability employing a double-sided μTBS test. The other physicomechanical properties examined were adhesives’ oxygen inhibition layer (OIL), viscosity, hardness, elastic modulus, degree of conversion (DC), and in-situ DC. Both adhesive versions showed similar μTBS (P > 0.05), failure pattern (P > 0.05), and survival probability (P > 0.008). ER mode promoted resin tag formation and exhibited a slender adhesive layer for both adhesives. The newer adhesive version showed a thinner adhesive layer in general with narrower OIL (P < 0.001), less viscosity (P < 0.001), higher hardness (P < 0.05), elastic modulus (P < 0.05), DC (P < 0.001), and in-situ DC (P < 0.001). While the newly updated adhesive had superior physicomechanical properties with more fluidity, its dentin bonding efficacy and survival probability were comparable to its predecessor.

18 November 2021 in Scientific Reports
Verified
Journal Article
Open access
PDF file
RDRupak Dua
Rupak Dua
HJHugh Jones
Hugh Jones
PNPhilip C. Noble
Philip C. Noble
Recent advances in materials and manufacturing processes have allowed the fabrication of intricate implant surfaces to facilitate bony attachment. However, refinement and evaluation of these new design strategies are hindered by the cost and complications of animal studies, particularly during early iterations in the development process. To address this problem, we have previously constructed and validated an ex-vivo bone bioreactor culture system that can maintain the viability of bone samples for an extended period ex-vivo. In this study, we investigated the mineralization of a titanium wire mesh scaffold under both static and dynamic culturing using our ex vivo bioreactor system. Thirty-six cancellous bone cores were harvested from bovine metatarsals at the time of slaughter and divided into five groups under the following conditions: Group 1) Isolated bone cores placed in static culture, Group 2) Unloaded bone cores placed in static culture in contact with a fiber-mesh metallic scaffold, Group 3) Bone cores placed in contact with a fiber-mesh metallic scaffold under the constant pressure of 150 kPa, Group 4) Bone core placed in contact with a fiber-mesh metallic scaffold and exposed to cyclic loading with continuous perfusion flow of media within the ex-vivo culture system and Group 5) Bone core evaluated on Day 0 to serve as a positive control for comparison with all other groups at weeks 4 and 7. Bone samples within Groups 1–4 were incubated for 4 and 7 weeks and then evaluated using histological examination (H&E) and the Live-Dead assay (Life Technologies). Matrix deposits on the metallic scaffolds were examined with scanning electron microscopy (SEM), while the chemical composition of the matrix was measured using energy-dispersive x-ray spectroscopy (EDX). We found that the viability of bone cores was maintained after seven weeks of loading in our ex vivo system. In addition, SEM images revealed crystallite-like structures on the dynamically loaded metal coupons (Group 4), corresponding to the initial stages of mineralization. EDX results further confirmed the presence of carbon at the interface and calcium phosphates in the matrix. We conclude that a bone bioreactor can be used as an alternate tool for in-vivo bone ingrowth studies of new implant surfaces or coatings.

1 June 2021 in Bone Reports
Verified
Journal Article
Open access
RDRupak Dua
Rupak Dua
HJHugh Jones
Hugh Jones
PNPhilip C. Noble
Philip C. Noble
Several different bioreactors have been developed to study bone biology. Keeping a bone viable for long-term studies is still a challenge. We have developed an ex-vivo bone bioreactor that can keep the ex-vivo live bone viable for more than 4 weeks. Keeping a bone viable for over a month can be used as an alternative model for in-vivo experiments in animals. We hypothesize that the perfusion flow and mechanical load on the bone provide a real-time environment for the bone to survive. Cancellous bones were harvested from the bovine metatarsals and were placed in the dynamic culture with cyclic loading at regular intervals. After a period of week 4, the bone cores were retrieved from the bioreactor and tested for viability using calcein-AM and ethidium homodimer −1 fluorescent dyes and were compared with the cores that were placed in static culture with and without any loads on them and Day 0 bone core that acted as a positive control. The bone blocks were then fixed in 10% formalin, and bone mineral density was evaluated using a DXA scanner before staining them for H&E to study the morphological changes. Results revealed that the bone cultured in the bioreactor was viable as compared to the one in the static culture with and without constant load. Bone cores cultured in our ex-vivo bioreactor system also maintained their morphology and no statistical difference was found in the bone mineral density compared to positive controls and the statistical difference was found when compared with the cores cultured in static culture. This tool can be used to study bone biology for various applications such as bone ingrowth studies, to study the effect of drugs, hormones, or any growth factors, and much more.

19 June 2024 in Journal of Materials Science: Materials in Medicine
Verified
Journal Article
Open access
PDF file
HHHanieh Hadady
Hanieh Hadady
AAArefin Alam
Arefin Alam
IKIndu Khurana
Indu Khurana
IMIsha Mutreja
Isha Mutreja
Dhiraj KumarDhiraj Kumar
Dhiraj Kumar
RDRupak Dua
Rupak Dua
Orthopedic and dental implant failure continues to be a significant concern due to localized bacterial infections. Previous studies have attempted to improve implant surfaces by modifying their texture and roughness or coating them with antibiotics to enhance antibacterial properties for implant longevity. However, these approaches have demonstrated limited effectiveness. In this study, we attempted to engineer the titanium (Ti) alloy surface biomimetically at the nanometer scale, inspired by the cicada wing nanostructure using alkaline hydrothermal treatment (AHT) to simultaneously confer antibacterial properties and support the adhesion and proliferation of mammalian cells. The two modified Ti surfaces were developed using a 4 h and 8 h AHT process in 1 N NaOH at 230 °C, followed by a 2-hour post-calcination at 600 °C. We found that the control plates showed a relatively smooth surface, while the treatment groups (4 h & 8 h AHT) displayed nanoflower structures containing randomly distributed nano-spikes. The results demonstrated a statistically significant decrease in the contact angle of the treatment groups, which increased wettability characteristics. The 8 h AHT group exhibited the highest wettability and significant increase in roughness 0.72 ± 0.08 µm (P < 0.05), leading to more osteoblast cell attachment, reduced cytotoxicity effects, and enhanced relative survivability. The alkaline phosphatase activity measured in all different groups indicated that the 8 h AHT group exhibited the highest activity, suggesting that the surface roughness and wettability of the treatment groups may have facilitated cell adhesion and attachment and subsequently increased secretion of extracellular matrix. Overall, the findings indicate that biomimetic nanotextured surfaces created by the AHT process have the potential to be translated as implant coatings to enhance bone regeneration and implant integration. Graphical Abstract