Xiaolong Huang

Dr. Xiaolong Huang


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 March 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
XFXudong Fan
Xudong Fan
XHXiaolong Huang
Xiaolong Huang
YKYang Kang
Yang Kang
CLCan Li
Can Li
NLNING LI
NING LI
CWChunsheng Weng
Chunsheng Weng
We report the realization of an ultra-broadband bending beam based on acoustic metamaterials by the theoretical prediction and the numerical validation. The proposed structure is composed of a series of straight tubes with spatially modulated depths. We analytically derive the depth profile required for the generation of an ultra-broadband bending beam, and examine the performance of the metastructure numerically. The design is then extended for the generation of a three-dimensional bottle beam. The transverse trapping behaviours on small rigid objects by the bottle beam are investigated based on the force potential. Our work will help the further study of broadband acoustic meta-structures, and may also find applications in a variety of fields such as ultrasound imaging, health monitoring and particle manipulations.

10 September 2021 in Energies
Verified
Journal Article
Open access
PDF file
XHXiaolong Huang
Xiaolong Huang
NLNING LI
NING LI
YKYang Kang
Yang Kang
Fill fraction not only has a profound impact on the process of deflagration to detonation in pulsed detonation engine, but also affects the propulsion performance in both flight and ground tests. In this paper, a novel optical diagnostic method based on detonation exhaust radiation in visible and near-infrared region within 300–2600 nm is developed to determine the current working state in the gas–liquid two-phase pulsed detonation cycle. The results show that the radiation characteristic in each stage of detonation cycle is unique and can be a good indicator to infer the fill fraction. This is verified experimentally by comparison with the laser absorption spectroscopy method, which utilizes a DFB laser driven by ramp injection current to scan H2O transition of 1391.67 nm at a frequency of 20 kHz. Due to concentrated radiation intensity, time duration reaching accumulated radiant energy ratio of 50% in detonation status would be smaller than 1.2 ms, and detonation status would be easily distinguished from deflagration with this critical condition. In addition, the variation of important intermediates OH, CH, and C2 radicals during detonation combustion are obtained according to the analysis of detonation spectrum, which can also be proposed as a helpful optical diagnostics method for the combustion condition based on C radical concentration. The study demonstrates the feasibility of optical diagnostics based on radiation in visible and near-infrared regions, which could provide an alternative means to diagnose and improve pulsed detonation engine performance.

7 October 2021 in International Journal of Turbo & Jet-Engines
Verified
Journal Article
Closed access
XHXiaolong Huang
Xiaolong Huang
NLNING LI
NING LI
YKYang Kang
Yang Kang
HWHui Wang
Hui Wang
CWChunsheng Weng
Chunsheng Weng
In order to study the influence of different nozzle configurations on the gas–liquid two-phase pulse detonation engine (PDE) propulsion performance, the measurement system based on the tunable diode laser absorption spectroscopy (TDLAS) technology is built to measure the velocity and the temperature, while the high frequency dynamic pressure sensor is used to measure the nozzle gas pressure. Based on the momentum principle, the contribution mechanism of unsteady gas jet on thrust is obtained indirectly by TDLAS data. The results show that the impulses of PDE with non-nozzle, convergent nozzle, divergent nozzle and convergent–divergent nozzle are 1.95, 2.08, 1.85 and 2.16 N∙s within 20 ms of the exhaust period, respectively. The analysis reveals that the impulses of PDE with convergent and convergent–divergent nozzles are larger than that with non-nozzle, while the impulse of PDE with divergent nozzle is smaller than that with non-nozzle. The research results in this paper can provide reference for the design of nozzles for PDE.