Purpose: Functional MRI (fMRI) at the mesoscale of cortical layers and columns requires both sensitivity and specificity, which can be compromised if the imaging method is affected by vascular artifacts, particularly cortical draining veins at the pial surface. Recent studies have shown that cerebral blood volume (CBV) imaging is more specific to the actual laminar locus of neural activity than BOLD imaging when using standard gradient-echo (GE) EPI sequences. Gradient and Spin Echo (GRASE) BOLD imaging has also shown greater specificity when compared with GE-BOLD. Methods: Here we directly compare CBV and BOLD contrasts in high-resolution imaging of the primary motor cortex for laminar fMRI in four combinations of signal labeling, VASO (CBV) and BOLD with 3D GE-EPI and zoomed 3D GRASE image readouts. Results: We find that both CBV imaging using EPI-VASO and BOLD imaging using GRASE-BOLD, show similar specificity and sensitivity and are thus useful tools for mesoscopic fMRI in the human cortex. Conclusion: These techniques demonstrate sufficient sensitivity and specificity to allow layer-fMRI to be used by neuroscientists in a wide range of investigations of depth-dependent neural circuitry in the human brain.
12 August 2019 in IEEE Transactions on Medical Imaging
This work develops a novel, simultaneous multi-VENC and simultaneous multi-slice (SMV+SMS) imaging in a single acquisition for robust phase contrast (PC) MRI. To this end, the pulse sequence was designed to permit concurrent acquisition of multiple VENCs as well as multiple slices on a shared frequency encoding gradient, in which each effective echo time for multiple VENCs was controlled by adjusting net gradient area while multiple slices were simultaneously excited by employing multiband resonance frequency (RF) pulses. For VENC and slice separation, RF phase cycling and gradient blip were applied to create both inter-VENC and inter-slice shifts along phase encoding direction, respectively. With an alternating RF phase cycling that generates oscillating steady-state with low and high signal amplitude, the acquired multi-VENC k-space was reformulated into 3D undersampled k-space by generating a virtual dimension along VENC direction for modulation induced artifact reduction. In vivo studies were conducted to validate the feasibility of the proposed method in comparison with conventional PC MRI. The proposed method shows comparable performance to the conventional method in delineating both low and high flow velocities across cardiac phases with high spatial coverage without apparent artifacts. In the presence of high flow velocity that is above the VENC value, the proposed method exhibits clear depiction of flow signals over conventional method, thereby leading to high VNR image with improved velocity dynamic range.