27 November 2023 in Nature Methods
To increase granularity in human neuroimaging science, we designed and built a next-generation 7 Tesla magnetic resonance imaging scanner to reach ultra-high resolution by implementing several advances in hardware. To improve spatial encoding and increase the image signal-to-noise ratio, we developed a head-only asymmetric gradient coil (200 mT m−1, 900 T m−1s−1) with an additional third layer of windings. We integrated a 128-channel receiver system with 64- and 96-channel receiver coil arrays to boost signal in the cerebral cortex while reducing g-factor noise to enable higher accelerations. A 16-channel transmit system reduced power deposition and improved image uniformity. The scanner routinely performs functional imaging studies at 0.35–0.45 mm isotropic spatial resolution to reveal cortical layer functional activity, achieves high angular resolution in diffusion imaging and reduces acquisition time for both functional and structural imaging.
24 August 2021 in Magnetic Resonance in Medicine
Purpose: To optimize pseudo‐continuous arterial spin labeling (pCASL) for 7 T, and to further improve the labeling efficiency with parallel RF transmission transmit B1 () shimming.Methods: pCASL parameters were optimized based on field distributions at 7 T with simulation. To increase labeling efficiency, the amplitude at inflowing arteries was increased with parallel RF transmission shimming. The “indv‐shim” with shimming weights calculated for each individual subject, and the “univ‐shim” with universal weights calculated on a group of 12 subjects, were compared with circular polarized (CP) shim. The optimized pCASL sequences with three shimming modes (indv‐shim, univ‐shim, and CP‐shim) were evaluated in 6 subjects who underwent two repeated scans 24 hours apart, along with a pulsed ASL sequence. Quantitative metrics including mean amplitude, perfusion, and intraclass correlation coefficient were calculated. The optimized 7T pCASL was compared with standard 3T pCASL on 5 subjects, using spatial SNR and temporal SNR.Results: The optimal pCASL parameter set (RF duration/gap = 300/250 us, ) achieved robust perfusion measurement in the presence of inhomogeneities. Both indv‐shim and univ‐shim significantly increased amplitude compared with CP‐shim in simulation and in vivo experiment (P < .01). Compared with CP‐shim, perfusion signal was increased by 9.5% with indv‐shim (P < .05) and by 5.3% with univ‐shim (P = .35). All three pCASL sequences achieved fair to good repeatability (intraclass correlation coefficient ≥ 0.5). Compared with 3T pCASL, the optimized 7T pCASL achieved 78.3% higher spatial SNR and 200% higher temporal SNR.Conclusion: The optimized pCASL achieved robust perfusion imaging at 7 T, while both indv‐shim and univ‐shim further increased labeling efficiency.
23 May 2025 in Magnetic Resonance in Medicine
Purpose: Peripheral nerve stimulation (PNS) remains a physiologic limitation to boosting spatiotemporal resolution with more powerful gradients. We investigate discrepancies in previous measurements and model predictions from PNS experienced by volunteers scanned with the investigational “Impulse” gradient coil on the NexGen 7T scanner.Methods: Twenty‐nine volunteers (18 males, mean ± standard deviation age 52.2 ± 17.1 years) underwent PNS characterizations in the scanner. The process was repeated after the subject positions were moved by 2 and 4 cm toward the feet, away from isocenter. These new data were compared with prior experimental data acquired at the factory (32 volunteers, 16 males, mean ± standard deviation age 58.3 ± 13.5 years) and to modeling results initially used to guide the gradient winding pattern.Results: The PNS threshold for the x‐axis (left–right) was significantly below the threshold level predicted by the model used to optimize the wiring pattern and thresholds measured in the factory, whereas there was closer agreement for the y‐axis (anterior–posterior) and z‐axis (superior–inferior). The x‐axis threshold increased as the subject was moved in the Z‐direction toward the foot end of the magnet, at the expense of gradient nonlinearity distortions. Sensitivity of the threshold for the x‐axis was measured as 20 mT/m per centimeter Z‐offset.Conclusion: The PNS threshold of the x‐axis measured in the scanner was much lower than predicted by the optimization model and as measured at the factory. Our measurements verified that PNS thresholds of asymmetric head gradient coils were sensitive to head position, subject variability, and age. The discrepancy of the PNS prediction model remains to be elucidated.
30 December 2025 in Magnetic Resonance in Medicine
24 April 2025 in Magnetic Resonance in Medicine