Ning Zhang

Mrs. Ning Zhang

National Research Center for Rehabilitation Technical Aids

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 February 2023 in Sensors
Verified
Journal Article
Open access
PDF file
YHYi Han
Yi Han
XLXiangzhi Liu
Xiangzhi Liu
NZNing Zhang
Ning Zhang
XZXiufeng Zhang
Xiufeng Zhang
BZBin Zhang
Bin Zhang
JYJingang Yi
Jingang Yi
The rehabilitation evaluation of Parkinson’s disease has always been the research focus of human assistive systems. It is a research hotspot to objectively and accurately evaluate the gait condition of Parkinson’s disease patients, thereby adjusting the actuators of the human–machine system and making rehabilitation robots better adapt to the recovery process of patients. The rehabilitation evaluation of Parkinson’s disease has always been the research focus of rehabilitation robots. It is a research hotspot to be able to objectively and accurately evaluate the recovery of Parkinson’s disease patients, thereby adjusting the driving module of the human–machine collaboration system in real time, so that rehabilitation robots can better adapt to the recovery process of Parkinson’s disease. The gait task in the Unified Parkinson’s Disease Rating Scale (UPDRS) is a widely accepted standard for assessing the gait impairments of patients with Parkinson’s disease (PD). However, the assessments conducted by neurologists are always subjective and inaccurate, and the results are determined by the neurologists’ observation and clinical experience. Thus, in this study, we proposed a novel machine learning-based method of automatically assessing the gait task in UPDRS with wearable sensors as a more convenient and objective alternative means for PD gait assessment. In the design, twelve gait features, including three spatial–temporal features and nine kinematic features, were extracted and calculated from two shank-mounted IMUs. A novel nonlinear model is developed for calculating the score of gait task from the gait features. Twenty-five PD patients and twenty-eight healthy subjects were recruited for validating the proposed method. For comparison purpose, three traditional models, which have been used in previous studies, were also tested by the same dataset. In terms of percentages of participants, 84.9%, 73.6%, 73.6%, and 66.0% of the participants were accurately assigned into the true level with the proposed nonlinear model, the support vector machine model, the naive Bayes model, and the linear regression model, respectively, which indicates that the proposed method has a good performance on calculating the score of the UPDRS gait task and conformance with the rating done by neurologists.

26 July 2023 in Sensors
Verified
Journal Article
Open access
PDF file
XHXiangyu Han
Xiangyu Han
QZQian Zhai
Qian Zhai
NZNing Zhang
Ning Zhang
XZXiufeng Zhang
Xiufeng Zhang
LHLong He
Long He
Tao LiuTao Liu
Tao Liu
Noncontact vital sign monitoring based on radar has attracted great interest in many fields. Heart Rate Variability (HRV), which measures the fluctuation of heartbeat intervals, has been considered as an important indicator for general health evaluation. This paper proposes a new algorithm for HRV monitoring in which frequency-modulated continuous-wave (FMCW) radar is used to separate echo signals from different distances, and the beamforming technique is adopted to improve signal quality. After the phase reflecting the chest wall motion is demodulated, the acceleration is calculated to enhance the heartbeat and suppress the impact of respiration. The time interval of each heartbeat is estimated based on the smoothed acceleration waveform. Finally, a joint optimization algorithm was developed and is used to precisely segment the acceleration signal for analyzing HRV. Experimental results from 10 participants show the potential of the proposed algorithm for obtaining a noncontact HRV estimation with high accuracy. The proposed algorithm can measure the interbeat interval (IBI) with a root mean square error (RMSE) of 14.9 ms and accurately estimate HRV parameters with an RMSE of 3.24 ms for MEAN (the average value of the IBI), 4.91 ms for the standard deviation of normal to normal (SDNN), and 9.10 ms for the root mean square of successive differences (RMSSD). These results demonstrate the effectiveness and feasibility of the proposed method in emotion recognition, sleep monitoring, and heart disease diagnosis.

8 June 2022 in Sensors
Verified
Journal Article
Open access
PDF file
YXYang Xia
Yang Xia
JLJiejunyi Liang
Jiejunyi Liang
QLQuanlin Li
Quanlin Li
PXPeiyang Xin
Peiyang Xin
NZNing Zhang
Ning Zhang
The problem of 3D gaze estimation can be viewed as inferring the visual axes from eye images. It remains a challenge especially for the head-mounted gaze tracker (HMGT) with a simple camera setup due to the complexity of the human visual system. Although the mainstream regression-based methods could establish the mapping relationship between eye image features and the gaze point to calculate the visual axes, it may lead to inadequate fitting performance and appreciable extrapolation errors. Moreover, regression-based methods suffer from a degraded user experience because of the increased burden in recalibration procedures when slippage occurs between HMGT and head. To address these issues, a high-accuracy 3D gaze estimation method along with an efficient recalibration approach is proposed with head pose tracking in this paper. The two key parameters, eyeball center and camera optical center, are estimated in head frame with geometry-based method, so that a mapping relationship between two direction features is proposed to calculate the direction of the visual axis. As the direction features are formulated with the accurately estimated parameters, the complexity of mapping relationship could be reduced and a better fitting performance can be achieved. To prevent the noticeable extrapolation errors, direction features with uniform angular intervals for fitting the mapping are retrieved over human’s field of view. Additionally, an efficient single-point recalibration method is proposed with an updated eyeball coordinate system, which reduces the burden of calibration procedures significantly. Our experiment results show that the calibration and recalibration methods could improve the gaze estimation accuracy by 35 percent (from a mean error of 2.00 degrees to 1.31 degrees) and 30 percent (from a mean error of 2.00 degrees to 1.41 degrees), respectively, compared with the state-of-the-art methods.

6 November 2023 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
YGYu Gu
Yu Gu
JLJiaxing Li
Jiaxing Li
WFWu Fan
Wu Fan
NZNing Zhang
Ning Zhang
XZXiufeng Zhang
Xiufeng Zhang
Tao LiuTao Liu
Tao Liu
Prosthetic hands hold significant potential in aiding amputees to regain their manipulative abilities, instill confidence, and improve their quality of life. Nonetheless, the lack of compatibility between prosthetic devices and residual limbs could lead to secondary injuries, such as skin pressure ulcers caused by prolonged high-pressure states and restricted upper limb movements while using. These issues contribute to a high device abandonment rate among individuals with disabilities. In this study, a wearable monitoring system was initially designed and presented. Subsequently, multiindicators comprising motion deviation ( $\eta _{q}$ ), pressure distribution ( ${\eta _{p}}$ ), and proximity to pain pressure ( ${\eta _{\bar P}}$ ) were proposed, which were correspondingly derived from clinical criteria, pressure, and motion information. Then, a comprehensive assessment approach was proposed to evaluate the adaptability of prosthetic hands. Moreover, the proposed adaptability assessment approach based on the wearable monitoring system underwent testing on seven forearm amputees conducted under three loading conditions. The results were compared with a standard clinical scale, demonstrating a favorable evaluation performance (RMSE = 3.30, $R^{2} = 0.6019$ ). This research work enables quantitative adaptability evaluation of prosthetic hands and has the potential to aid in the optimization of prosthetic design.

20 May 2022 in Electronics
Verified
Journal Article
Open access
PDF file
YHYi Han
Yi Han
LCLiu Chenhao
Liu Chenhao
BZBin Zhang
Bin Zhang
NZNing Zhang
Ning Zhang
SWShuoyu Wang
Shuoyu Wang
XZXiufeng Zhang
Xiufeng Zhang
Gait recognition and rehabilitation has been a research hotspot in recent years due to its importance to medical care and elderly care. Active intelligent rehabilitation and assistance systems for lower limbs integrates mechanical design, sensing technology, intelligent control, and robotics technology, and is one of the effective ways to resolve the above problems. In this review, crucial technologies and typical prototypes of active intelligent rehabilitation and assistance systems for gait training are introduced. The limitations, challenges, and future directions in terms of gait measurement and intention recognition, gait rehabilitation evaluation, and gait training control strategies are discussed. To address the core problems of the sensing, evaluation and control technology of the active intelligent gait training systems, the possible future research directions are proposed. Firstly, different sensing methods need to be proposed for the decoding of human movement intention. Secondly, the human walking ability evaluation models will be developed by integrating the clinical knowledge and lower limb movement data. Lastly, the personalized gait training strategy for collaborative control of human–machine systems needs to be implemented in the clinical applications.

10 August 2021 in Sustainability
Verified
Journal Article
Open access
PDF file
XZXu Zhao
Xu Zhao
JZJie Zhang
Jie Zhang
NZNing Zhang
Ning Zhang
Yiik Diew WONGYiik Diew WONG
Yiik Diew WONG
YZYufang Zhou
Yufang Zhou
MMMeng Meng
Meng Meng
This study proposes a geographic information system (GIS)-based cellular automata (CA) model, which is designed for planning bikeways upon existing footpath networks within an urban area. The CA model was developed based on a GIS platform as a visual interface whereby spatiotemporal characteristics and spatial processing can be combined in a highly effective way. The host value of each CA cell is conditioned upon four indicator variables, namely cycling demand level, land-use nature, social value, and traffic safety. This model gives traffic planners a quick and intuitive framework to develop cycling facilities under limited land resources. A model prototype has been developed in a common desktop GIS and applied to a mid-sized rapidly developing area in Singapore.