Xiangzhi Liu

Mr. Xiangzhi Liu

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 December 2023 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Open access
XLXiangzhi Liu
Xiangzhi Liu
XZXiangliang Zhang
Xiangliang Zhang
BZBin Zhang
Bin Zhang
BZBin Zhou
Bin Zhou
ZHZexia He
Zexia He
Tao LiuTao Liu
Tao Liu
Walking is one of the most common daily movements of the human body. Therefore, quantitative evaluation of human walking has been commonly used to assist doctors in grasping the disease degree and rehabilitation process of patients in the clinic. Compared with the kinematic characteristics, the ground reaction force (GRF) during walking can directly reflect the dynamic characteristics of human walking. It can further help doctors understand the degree of muscle recovery and joint coordination of patients. This paper proposes a GRF estimation method based on the elastic elements and Newton-Euler equation hybrid driving GRF estimation method. Compared with the existing research, the innovations are as follows. i) The hardware system consists of only two inertial measurement units (IMUs) placed on shanks. The acquisition of the overall motion characteristics of human walking is realized through the simplified four-link walking model and the thigh prediction method. ii) The method was validated not only on 10 healthy subjects but also on 11 Parkinson’s patients and 10 stroke patients with normalized mean absolute errors (NMAEs) of 5.95%±1.32%, 6.09%±2.00%, 5.87%±1.59%. iii) This paper proposes a dynamic balance assessment method based on the acquired motion data and the estimated GRF. It evaluates the overall balance ability and fall risk at four key time points for all subjects recruited. Because of the low-cost system, ease of use, low motion interference and environmental constraints, and high estimation accuracy, the proposed GRF estimation method and walking balance automatic assessment have broad clinical value.

13 February 2023 in Sensors
Verified
Journal Article
Open access
PDF file
YHYi Han
Yi Han
XLXiangzhi Liu
Xiangzhi Liu
NZNing Zhang
Ning Zhang
XZXiufeng Zhang
Xiufeng Zhang
BZBin Zhang
Bin Zhang
JYJingang Yi
Jingang Yi
The rehabilitation evaluation of Parkinson’s disease has always been the research focus of human assistive systems. It is a research hotspot to objectively and accurately evaluate the gait condition of Parkinson’s disease patients, thereby adjusting the actuators of the human–machine system and making rehabilitation robots better adapt to the recovery process of patients. The rehabilitation evaluation of Parkinson’s disease has always been the research focus of rehabilitation robots. It is a research hotspot to be able to objectively and accurately evaluate the recovery of Parkinson’s disease patients, thereby adjusting the driving module of the human–machine collaboration system in real time, so that rehabilitation robots can better adapt to the recovery process of Parkinson’s disease. The gait task in the Unified Parkinson’s Disease Rating Scale (UPDRS) is a widely accepted standard for assessing the gait impairments of patients with Parkinson’s disease (PD). However, the assessments conducted by neurologists are always subjective and inaccurate, and the results are determined by the neurologists’ observation and clinical experience. Thus, in this study, we proposed a novel machine learning-based method of automatically assessing the gait task in UPDRS with wearable sensors as a more convenient and objective alternative means for PD gait assessment. In the design, twelve gait features, including three spatial–temporal features and nine kinematic features, were extracted and calculated from two shank-mounted IMUs. A novel nonlinear model is developed for calculating the score of gait task from the gait features. Twenty-five PD patients and twenty-eight healthy subjects were recruited for validating the proposed method. For comparison purpose, three traditional models, which have been used in previous studies, were also tested by the same dataset. In terms of percentages of participants, 84.9%, 73.6%, 73.6%, and 66.0% of the participants were accurately assigned into the true level with the proposed nonlinear model, the support vector machine model, the naive Bayes model, and the linear regression model, respectively, which indicates that the proposed method has a good performance on calculating the score of the UPDRS gait task and conformance with the rating done by neurologists.

9 January 2023 in IEEE Sensors Journal
Verified
Journal Article
Closed access
YGYu Gu
Yu Gu
YHYi Han
Yi Han
XLXiangzhi Liu
Xiangzhi Liu
NZNing Zhang
Ning Zhang
XZXiufeng Zhang
Xiufeng Zhang
Tao LiuTao Liu
Tao Liu
Motivation : Magnetic-Inertial Measurement Units (MIMUs) and flexible sensors are widely used in the wearable measurement system for human motion monitoring, clinical gait detection, and robotics motion control. However, MIMUs demonstrate measurement error due to magnetic disturbance in the indoor environment, and flexible sensors usually have low performance on linearity and accuracy. Objective : This paper is intended to eliminate the low-accuracy problem caused by magnetic disturbances and improve the measurement accuracy of MIMUs- flexible sensor based wearable systems. Approach : (1) a three-stage real-time data fusion (RT-ADF) algorithm is proposed, which contains an anti-disturbance filter based on a double Mathony filter along with a state observer, a signal holder for sensors’ data transmit synchronously, and a data fusion based on an adaptive Kalman filter. (2) The proposed algorithm is utilized and validated its performance on a designed MIMUs- flexible sensor wearable system. (3) 10 groups of knee motions (flexion/extension), 10 groups of hip motions (adduction/abduction), and 10 groups of elbow motions(flexion/extension) have been done by 7 subjects in the experiments. Main Results : The designed multi-sensor wearable system based on the presented data fusion algorithm demonstrates a high-accuracy performance under the magnetic disturbance environment, and the maximum root mean square error (RMSE) of the measured continuous three-dimensional motion angle of the knee, hip, and elbow cross all the experiments were 1.23°, 1.15°, 3.67° for each axis.

30 December 2022 in IEEE Transactions on Automation Science and Engineering
Verified
Journal Article
Closed access
XLXiangzhi Liu
Xiangzhi Liu
BZBin Zhou
Bin Zhou
BZBin Zhang
Bin Zhang
Tao LiuTao Liu
Tao Liu
The detection and evaluation of gait kinematics is vital for patient diagnosis and rehabilitation. Aiming at limitations of commonly used optical capture and wearable sensing systems in clinical applications, this paper proposes a thigh attitude angle prediction method based on the hip error tolerance from the kinematic data of two shank-mounted IMUs (Inertial Measurement Unit). The novelties of the proposed method are summarized as follows: i) It develops a parallel approach to regress variation of hip error tolerance for different subjects. This parallel approach, by simultaneously deconstructing the shank kinematics data via different regression algorithm including support vector machine, boosting tree, and stepwise linearity regression, is able to well accommodate the characteristics of both health subjects and patients. ii) It develops some evaluation indices based on gait symmetry, consistency, and activity to fully evaluate the human lower limbs motion performance in gait by only two IMUs. The effectiveness of the proposed method is verified by the experimental results among 8 healthy subjects and 16 cerebral infarction patients. For the healthy subjects, the estimated error of thigh prediction compared with Xsens and Vicon are $3.3 \pm {0.3^ \circ }$ and $3.5 \pm {0.7^ \circ }$ , respectively. For the patients, the estimated error compared with Xsens-measured angle is $4.8 \pm {1.7^ \circ }$ . Its broad significance in actual intelligent healthcare and robotics-assisted rehabilitation is three-fold: First, it is a recursive real-time method as it only needs data from the previous gait cycle to predict the thigh angle. Second, its accuracy meets the actual clinical needs. Third, it is a low-cost method that only needs two IMUs and has high potentials of clinical applications. Note to Practitioners —Gait is of great significance to quantify the degree of movement disorders in clinical practice, and the existing equipment is rarely able to meet the needs of full dimension, low cost, and low place constraints in clinical practice. This paper presents an innovative gait kinematic prediction method, which only uses two IMUs attached to the shanks to predict the orientation of thigh. Compared with related works, the proposed methods have achieved high-precision, real-time and low-cost acquisition. This paper is inspired by the problems of large number, high motion interference, and high cost of wearable gait measurement devices in clinical practice. The proposed method have potential to be integrated into exoskeletons and medical walking AIDS, which could greatly improve the comfort and control precision of the wearable system.

24 June 2025 in Bioengineering
Verified
Journal Article
Open access
PDF file
XLXiangzhi Liu
Xiangzhi Liu
XZXiangliang Zhang
Xiangliang Zhang
JLJuan Li
Juan Li
WPWenhao Pan
Wenhao Pan
YSYiping Sun
Yiping Sun
Tao LiuTao Liu
Tao Liu
The quantitative assessment of Parkinson’s disease (PD) is critical for guiding diagnosis, treatment, and rehabilitation. Conventional clinical evaluations—heavily dependent on manual rating scales such as the Unified Parkinson’s Disease Rating Scale (UPDRS)—are time-consuming and prone to inter-rater variability. In this study, we propose a fully automated UPDRS gait-scoring framework. Our method combines (a) surface electromyography (EMG) signals and (b) inertial measurement unit (IMU) data into a single deep learning model. Our end-to-end network comprises three specialized branches—a diagnosis head, an evaluation head, and a balance head—whose outputs are integrated via a customized fusion-detection module to emulate the multidimensional assessments performed by clinicians. We validated our system on 21 PD patients and healthy controls performing a simple walking task while wearing a four-channel EMG array on the lower limbs and 2 shank-mounted IMUs. It achieved a mean classification accuracy of 92.8% across UPDRS levels 0–2. This approach requires minimal subject effort and sensor setup, significantly cutting clinician workload associated with traditional UPDRS evaluations while improving objectivity. The results demonstrate the potential of wearable sensor-driven deep learning methods to deliver rapid, reliable PD gait assessment in both clinical and home settings.

8 October 2023 in Sensors
Verified
Journal Article
Open access
PDF file
Tao LiuTao Liu
Tao Liu
XLXiangzhi Liu
Xiangzhi Liu
Due to the advantages of ease of use, less motion disturbance, and low cost, wearable systems have been widely used in the human–machine interaction (HRI) field. However, HRI in complex clinical rehabilitation scenarios has further requirements for wearable sensor systems, which has aroused the interest of many researchers. However, the traditional wearable system has problems such as low integration, limited types of measurement data, and low accuracy, causing a gap with the actual needs of HRI. This paper will introduce the latest progress in the current wearable systems of HRI from four aspects. First of all, it introduces the breakthroughs of current research in system integration, which includes processing chips and flexible sensing modules to reduce the system’s volume and increase battery life. After that, this paper reviews the latest progress of wearable systems in electrochemical measurement, which can extract single or multiple biomarkers from biological fluids such as sweat. In addition, the clinical application of non-invasive wearable systems is introduced, which solves the pain and discomfort problems caused by traditional clinical invasive measurement equipment. Finally, progress in the combination of current wearable systems and the latest machine-learning methods is shown, where higher accuracy and indirect acquisition of data that cannot be directly measured is achieved. From the evidence presented, we believe that the development trend of wearable systems in HRI is heading towards high integration, multi-electrochemical measurement data, and clinical and intelligent development.