Purpose: To develop and characterize a 128‐channel head array for brain imaging at 10.5 T, evaluate signal‐to‐noise ratio (SNR) relative to ultimate intrinsic SNR (uiSNR) and lower field strengths, and demonstrate human brain anatomical and functional imaging with this unique magnetic field and high‐channel‐count array. Methods: The coil consists of a 16‐channel self‐decoupled loop transmit/receive (16Tx/Rx) array with a 112‐loop receive‐only (Rx) insert. Interactions between the 16Tx/Rx array and the 112Rx insert were mitigated using coaxial cable traps placed every 1/16 of a wavelength on each feed cable, locating most preamplifier boards outside the transmitter field, and miniaturizing those placed directly on individual coils. Results: The effect of the 112Rx insert on the circumscribing 16Tx/Rx array was minimized, leading to similar transmit field maps obtained experimentally with and without the 112Rx array in place and by electromagnetic simulations of the 16Tx/Rx array alone. The 128‐channel array captured 77% of uiSNR centrally. Significantly higher 1/g‐factor values across the whole brain was achieved compared with 7 T. Excellent SNR, high parallel‐imaging performance, and minimal Tx‐Rx interactions collectively facilitated acquisition of high‐quality, high‐resolution, proof‐of‐concept functional and anatomical images, including with power‐demanding sequences in the human brain. Conclusions: Counterintuitive to expectations based on magnetic fields less than or equal to 7 T, the higher channel counts provided SNR gains centrally, capturing about 80% uiSNR. The fraction of uiSNR achieved centrally in 64Rx, 80Rx, and 128Rx arrays suggested that a plateau was being reached at 80%. At this plateau, B 0 ‐dependent SNR gains for 10.5 T relative to 7 T were approximately linear to quadratic for the periphery and the center, respectively.
Purpose: Toward pushing the boundaries of ultrahigh fields for human brain imaging, we wish to evaluate experimentally achievable SNR relative to ultimate intrinsic SNR (uiSNR) at 10.5T, develop design strategies toward approaching the latter, quantify magnetic field–dependent SNR gains, and demonstrate the feasibility of whole‐brain, high‐resolution human brain imaging at this uniquely high field strength.Methods: A dual row 16‐channel self‐decoupled transmit (Tx) and receive (Rx) array was developed for 10.5T using custom Tx/Rx switches. A 64‐channel receive‐only array was built to fit into the 16‐channel Tx/Rx array. Electromagnetic modeling and experiments were used to define safe operational power limits. Experimental SNR was evaluated relative to uiSNR at 10.5T and 7T.Results: The 64‐channel Rx array alone captured approximately 50% of the central uiSNR at 10.5T, while an identical array developed for 7T captured about 76% of uiSNR at 7T. The 16‐channel Tx/80‐channel Rx configuration brought the fraction of uiSNR captured at 10.5T to levels comparable to the 64‐channel Rx array at 7T. SNR data displayed an approximate dependence over a large central region when evaluated in the context of uiSNR. Whole‐brain, high‐resolution ‐weighted and T1‐weighted anatomical and gradient‐recalled‐echo BOLD‐EPI functional MRI images were obtained at 10.5T for the first time with such an advanced array.Conclusion: We demonstrated the ability to approach the uiSNR at 10.5T over the human brain, achieving large SNR gains over 7T, currently the most commonly used ultrahigh‐field platform. Whole‐brain, high‐resolution anatomical and EPI‐based functional MRI data were obtained at 10.5T, illustrating the promise of greater than 10T fields in studying the human brain.
For human head magnetic resonance imaging at 10.5 tesla (T), we built an 8-channel transceiver dipole antenna array and evaluated the influence of coaxial feed cables. The influence of coaxial feed cables was evaluated in simulation and compared against a physically constructed array in terms of transmit magnetic field (B1+) and specific absorption rate (SAR) efficiency. A substantial drop (23.1% in simulation and 20.7% in experiment) in B1+ efficiency was observed with a tight coaxial feed cable setup. For the investigation of the feed location, the center-fed dipole antenna array was compared to two 8-channel end-fed arrays: monopole and sleeve antenna arrays. The simulation results with a phantom indicate that these arrays achieved ~24% higher SAR efficiency compared to the dipole antenna array. For a human head model, we observed 30.8% lower SAR efficiency with the 8-channel monopole antenna array compared to the phantom. Importantly, our simulation with the human model indicates that the sleeve antenna arrays can achieve 23.8% and 21% higher SAR efficiency compared to the dipole and monopole antenna arrays, respectively. Finally, we obtained high-resolution human cadaver images at 10.5 T with the 8-channel sleeve antenna array.
The upper bounds of the signal‐to‐noise ratio (also known as the “ultimate intrinsic signal‐to‐noise ratio” (UISNR)) for internal and external coils were calculated. In the calculation, the body was modeled as a dielectric cylinder with a small coaxial cylindrical cavity in which internal coils could be placed. The calculated UISNR values can be used as reference solutions to evaluate the performance of internal MRI coils. As examples, we evaluated the performance of a loopless antenna and an endourethral coil design by comparing their ISNR with the UISNR. Magn Reson Med 52:640–649, 2004.