Alireza Sadeghi-Tarakameh

Dr. Alireza Sadeghi-Tarakameh

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 November 2019 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
ASAlireza Sadeghi-Tarakameh
Alireza Sadeghi-Tarakameh
LDLance DelaBarre
Lance DelaBarre
RLRussell L. Lagore
Russell L. Lagore
ATAngel Torrado-Carvajal
Angel Torrado-Carvajal
XWXiaoping Wu
Xiaoping Wu
YEYigitcan Eryaman
Yigitcan Eryaman

13 March 2025 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
RLRussell L. Lagore
Russell L. Lagore
ASAlireza Sadeghi-Tarakameh
Alireza Sadeghi-Tarakameh
AGAndrea Grant
Andrea Grant
MWMatt Waks
Matt Waks
EAEdward Auerbach
Edward Auerbach
KUKamil Uğurbil
Kamil Uğurbil
Purpose: To develop and characterize a 128‐channel head array for brain imaging at 10.5 T, evaluate signal‐to‐noise ratio (SNR) relative to ultimate intrinsic SNR (uiSNR) and lower field strengths, and demonstrate human brain anatomical and functional imaging with this unique magnetic field and high‐channel‐count array. Methods: The coil consists of a 16‐channel self‐decoupled loop transmit/receive (16Tx/Rx) array with a 112‐loop receive‐only (Rx) insert. Interactions between the 16Tx/Rx array and the 112Rx insert were mitigated using coaxial cable traps placed every 1/16 of a wavelength on each feed cable, locating most preamplifier boards outside the transmitter field, and miniaturizing those placed directly on individual coils. Results: The effect of the 112Rx insert on the circumscribing 16Tx/Rx array was minimized, leading to similar transmit field maps obtained experimentally with and without the 112Rx array in place and by electromagnetic simulations of the 16Tx/Rx array alone. The 128‐channel array captured 77% of uiSNR centrally. Significantly higher 1/g‐factor values across the whole brain was achieved compared with 7 T. Excellent SNR, high parallel‐imaging performance, and minimal Tx‐Rx interactions collectively facilitated acquisition of high‐quality, high‐resolution, proof‐of‐concept functional and anatomical images, including with power‐demanding sequences in the human brain. Conclusions: Counterintuitive to expectations based on magnetic fields less than or equal to 7 T, the higher channel counts provided SNR gains centrally, capturing about 80% uiSNR. The fraction of uiSNR achieved centrally in 64Rx, 80Rx, and 128Rx arrays suggested that a plateau was being reached at 80%. At this plateau, B 0 ‐dependent SNR gains for 10.5 T relative to 7 T were approximately linear to quadratic for the periphery and the center, respectively.

16 October 2024 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
MWMatt Waks
Matt Waks
RLRussell L. Lagore
Russell L. Lagore
EAEdward Auerbach
Edward Auerbach
AGAndrea Grant
Andrea Grant
ASAlireza Sadeghi-Tarakameh
Alireza Sadeghi-Tarakameh
KUKamil Uğurbil
Kamil Uğurbil
Purpose: Toward pushing the boundaries of ultrahigh fields for human brain imaging, we wish to evaluate experimentally achievable SNR relative to ultimate intrinsic SNR (uiSNR) at 10.5T, develop design strategies toward approaching the latter, quantify magnetic field–dependent SNR gains, and demonstrate the feasibility of whole‐brain, high‐resolution human brain imaging at this uniquely high field strength.Methods: A dual row 16‐channel self‐decoupled transmit (Tx) and receive (Rx) array was developed for 10.5T using custom Tx/Rx switches. A 64‐channel receive‐only array was built to fit into the 16‐channel Tx/Rx array. Electromagnetic modeling and experiments were used to define safe operational power limits. Experimental SNR was evaluated relative to uiSNR at 10.5T and 7T.Results: The 64‐channel Rx array alone captured approximately 50% of the central uiSNR at 10.5T, while an identical array developed for 7T captured about 76% of uiSNR at 7T. The 16‐channel Tx/80‐channel Rx configuration brought the fraction of uiSNR captured at 10.5T to levels comparable to the 64‐channel Rx array at 7T. SNR data displayed an approximate dependence over a large central region when evaluated in the context of uiSNR. Whole‐brain, high‐resolution ‐weighted and T1‐weighted anatomical and gradient‐recalled‐echo BOLD‐EPI functional MRI images were obtained at 10.5T for the first time with such an advanced array.Conclusion: We demonstrated the ability to approach the uiSNR at 10.5T over the human brain, achieving large SNR gains over 7T, currently the most commonly used ultrahigh‐field platform. Whole‐brain, high‐resolution anatomical and EPI‐based functional MRI data were obtained at 10.5T, illustrating the promise of greater than 10T fields in studying the human brain.

23 June 2020 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
ASAlireza Sadeghi-Tarakameh
Alireza Sadeghi-Tarakameh
GAGregor Adriany
Gregor Adriany
GMGregory J. Metzger
Gregory J. Metzger
RLRussell L. Lagore
Russell L. Lagore
SJSteve Jungst
Steve Jungst
YEYigitcan Eryaman
Yigitcan Eryaman

22 April 2024 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
BZBei Zhang
Bei Zhang
JRJerahmie Radder
Jerahmie Radder
IGIlias Giannakopoulos
Ilias Giannakopoulos
AGAndrea Grant
Andrea Grant
RLRussell Lagore
Russell Lagore
KUKamil Uğurbil
Kamil Uğurbil
Purpose: We examined magnetic field dependent SNR gains and ability to capture them with multichannel receive arrays for human head imaging in going from 7 T, the most commonly used ultrahigh magnetic field (UHF) platform at the present, to 10.5 T, which represents the emerging new frontier of >10 T in UHFs.Methods: Electromagnetic (EM) models of 31‐channel and 63‐channel multichannel arrays built for 10.5 T were developed for 10.5 T and 7 T simulations. A 7 T version of the 63‐channel array with an identical coil layout was also built. Array performance was evaluated in the EM model using a phantom mimicking the size and electrical properties of the human head and a digital human head model. Experimental data was obtained at 7 T and 10.5 T with the 63‐channel array. Ultimate intrinsic SNR (uiSNR) was calculated for the two field strengths using a voxelized cloud of dipoles enclosing the phantom or the digital human head model as a reference to assess the performance of the two arrays and field depended SNR gains.Results: uiSNR calculations in both the phantom and the digital human head model demonstrated SNR gains at 10.5 T relative to 7 T of 2.6 centrally, ˜2 at the location corresponding to the edge of the brain, ˜1.4 at the periphery. The EM models demonstrated that, centrally, both arrays captured ˜90% of the uiSNR at 7 T, but only ˜65% at 10.5 T, leading only to ˜2‐fold gain in array SNR in going from 7 to 10.5 T. This trend was also observed experimentally with the 63‐channel array capturing a larger fraction of the uiSNR at 7 T compared to 10.5 T, although the percentage of uiSNR captured were slightly lower at both field strengths compared to EM simulation results.Conclusions: Major uiSNR gains are predicted for human head imaging in going from 7 T to 10.5 T, ranging from ˜2‐fold at locations corresponding to the edge of the brain to 2.6‐fold at the center, corresponding to approximately quadratic increase with the magnetic field. Realistic 31‐ and 63‐channel receive arrays, however, approach the central uiSNR at 7 T, but fail to do so at 10.5 T, suggesting that more coils and/or different type of coils will be needed at 10.5 T and higher magnetic fields.

26 January 2023 in PLOS ONE
Verified
Journal Article
Open access
PDF file
EKEhsan Kazemivalipour
Ehsan Kazemivalipour
ASAlireza Sadeghi-Tarakameh
Alireza Sadeghi-Tarakameh
BKBoris Keil
Boris Keil
YEYigitcan Eryaman
Yigitcan Eryaman
EAErgin Atalar
Ergin Atalar
LGLaleh Golestanirad
Laleh Golestanirad
Background: Since the advent of magnetic resonance imaging (MRI) nearly four decades ago, there has been a quest for ever-higher magnetic field strengths. Strong incentives exist to do so, as increasing the magnetic field strength increases the signal-to-noise ratio of images. However, ensuring patient safety becomes more challenging at high and ultrahigh field MRI (i.e., ≥3 T) compared to lower fields. The problem is exacerbated for patients with conductive implants, such as those with deep brain stimulation (DBS) devices, as excessive local heating can occur around implanted lead tips. Despite extensive effort to assess radio frequency (RF) heating of implants during MRI at 1.5 T, a comparative study that systematically examines the effects of field strength and various exposure limits on RF heating is missing. Purpose: This study aims to perform numerical simulations that systematically compare RF power deposition near DBS lead models during MRI at common clinical and ultra-high field strengths, namely 1.5, 3, 7, and 10.5 T. Furthermore, we assess the effects of different exposure constraints on RF power deposition by imposing limits on either the B1+ or global head specific absorption rate (SAR) as these two exposure limits commonly appear in MRI guidelines. Methods: We created 33 unique DBS lead models based on postoperative computed tomography (CT) images of patients with implanted DBS devices and performed electromagnetic simulations to evaluate the SAR of RF energy in the tissue surrounding lead tips during RF exposure at frequencies ranging from 64 MHz (1.5 T) to 447 MHz (10.5 T). The RF exposure was implemented via realistic MRI RF coil models created based on physical prototypes built in our institutions. We systematically examined the distribution of local SAR at different frequencies with the input coil power adjusted to either limit the B1+ or the global head SAR. Results: The MRI RF coils at higher resonant frequencies generated lower SARs around the lead tips when the global head SAR was constrained. The trend was reversed when the constraint was imposed on B1+. Conclusion: At higher static fields, MRI is not necessarily more dangerous than at lower fields for patients with conductive leads. Specifically, when a conservative safety criterion, such as constraints on the global SAR, is imposed, coils at a higher resonant frequency tend to generate a lower local SAR around implanted leads due to the decreased B1+ and, by proxy, E field levels.