Spread spectrum time domain reflectometry (SSTDR) is a broadband electrical reflectometry technique that has been used to detect and locate faults on live electrical systems, including photovoltaic systems. In this article, we evaluate the detectability and localizability from both existing literature and our own measurements using SSTDR of open-circuit faults, connection faults, short-circuit faults, ground faults, arc faults, shading faults, bypass diode faults, and accelerated degradation faults in PV cells and mini-modules. Reflection magnitudes for these faults are compared. Preliminary data on buried and grounded PV cable along with arc fault detection are presented.
Sequence time-domain reflectometry (STDR) and spread spectrum time-domain reflectometry (SSTDR) detect, locate, and diagnose faults in live (energized) electrical systems. In this paper, we survey the present SSTDR literature for discussions on theory, algorithms used in its analysis, and its more prominent implementations and applications. Our review includes both scientific litera-ture and selected patents. We also discuss future applications of SSTDR.
This paper explains the use of supervised and unsupervised dictionary learning approaches on spread spectrum time domain (SSTDR) data to detect and locate disconnections in a PV array consisting of five panels. The aim is to decompose an SSTDR reflection signature into different components where each component has a physical interpretation, such as noise, environmental effects, and faults. In the unsupervised dictionary learning approach, the decomposed components are inspected to detect and localize faults. The maximum difference between actual and predicted location of the fault is 0.44 m on a system with five panels connected to an SSTDR box with a leader cable of 59.13 m and total length of 67.36 m including the effective length of the panels. In the supervised dictionary learning approach, the dictionary components are used to classify the SSTDR data to their respective fault types. Our results show a 97% accuracy using the supervised learning approach.
This article utilizes variational autoencoder (VAE) and spread spectrum time domain reflectometry (SSTDR) to detect, isolate, and characterize anomalous data (or faults) in a photovoltaic (PV) array. The goal is to learn the distribution of non-faulty input signals, inspect the reconstruction error of test signals, flag anomalies, and then locate or characterize the anomalous data using a predicted baseline rather than a fixed baseline that might be too rigid. The use of VAE handles imbalanced data better than other methods used for classification of PV faults because of its unsupervised nature. We consider only disconnects in this work, and our results show an overall accuracy of 96% for detecting true negatives (non-faulty data), a 99% true positive rate of detecting anomalies, 0.997 area under the ROC curve, 0.99 area under the precision-recall curve, and a maximum percentage absolute relative error of 0.40% in locating the faults on a 5-panel setup with a 59.13 m leader cable.
Spread spectrum time domain reflectometry (SSTDR) has been traditionally used to detect hard faults (open and short circuit faults) in transmission lines. Prior work has focused on loads at the end of the line with little research on impedances from circuit elements located in the middle of the line (i.e., not at the load) or on only one wire of the line. In this work we consider cases of transmission lines with different impedances on each wire. We refer to lines with the same impedance on both wires (positive and negative) as symmetric. Lines with different impedances on each wire are asymmetric. For highly localized impedances (approximately infinitesimal in length, i.e. with a length significantly smaller than the wavelength of the incident signal), the reflections and their effects on the propagating wave become difficult to describe with traditional transmission line theory. We provide analytical expressions for reflection coefficients for symmetric and asymmetric transmission lines and show that these formulae describe experimental measurements of capacitors and resistors to about 99% accuracy for the magnitudes and 75% for the phases.