Chris Deline

Chris Deline

Auto-generated profile, based on publicly available information

Chris Deline

National Laboratory of the Rockies, Golden, CO (United States)

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 December 2017 in IEEE Journal of Photovoltaics
Verified
Journal Article
Open access
DJDirk C. Jordan
Dirk C. Jordan
CDChris Deline
Chris Deline
SKSarah R. Kurtz
Sarah R. Kurtz
GKGregory M. Kimball
Gregory M. Kimball
MAMike Anderson
Mike Anderson
The degradation rate plays an important role in predicting and assessing the long-term energy generation of photovoltaics (PV) systems. Many methods have been proposed for extracting the degradation rate from operational data of PV systems, but most of the published approaches are susceptible to bias due to inverter clipping, module soiling, temporary outages, seasonality, and sensor degradation. In this paper, we propose a methodology for determining PV degradation leveraging available modeled clear-sky irradiance data rather than site sensor data, and a robust year-over-year rate calculation. We show the method to provide reliable degradation rate estimates even in the case of sensor drift, data shifts, and soiling. Compared with alternate methods, we demonstrate that the proposed method delivers the lowest uncertainty in degradation rate estimates for a fleet of 486 PV systems.

14 November 2018 in IEEE Journal of Photovoltaics
Verified
Journal Article
Open access
SPSilvana Ayala Pelaez
Silvana Ayala Pelaez
CDChris Deline
Chris Deline
SMSara M. MacAlpine
Sara M. MacAlpine
BMBill Marion
Bill Marion
Joshua S. SteinJoshua S. Stein
Joshua S. Stein
RKRaymond K. Kostuk
Raymond K. Kostuk
Models predicting rear irradiance for bifacial systems are critical to establish accurate estimates of energy yield. Here, we compare five published bifacial irradiance models, varying clearance, row spacing, tilt, and albedo to measure the sensitivity to these parameters. Bifacial energy gains (BG $_{\rm E}$ ) as high as 20% are predicted for some configurations. Model agreement is generally good for low ground clearance (clearance heights lower than 0.75 times the collector width), but at higher clearances, finite system size and edge effects become a significant factor in simulations, stretching assumptions of infinite system extent made in some models. In addition, rear irradiance uniformity is improved at high ground clearance, as expected. A test-bed construction and results are described for comparison between modeled and measured data in Golden, CO, USA. The investigations indicate that model agreement for BG $_{\rm E}$ calculation is better than 2% (absolute) when compared with measured results, depending on the system configuration.

6 March 2020 in Progress in Photovoltaics: Research and Applications
Verified
Journal Article
Closed access
PDF file
CDChris Deline
Chris Deline
SPSilvana Ayala Pelaez
Silvana Ayala Pelaez
SMSara MacAlpine
Sara MacAlpine
COCarlos Olalla
Carlos Olalla

7 August 2022 in Progress in Photovoltaics: Research and Applications
Verified
Journal Article
Open access
MTMarios Theristis
Marios Theristis
Joshua S. SteinJoshua S. Stein
Joshua S. Stein
CDChris Deline
Chris Deline
DJDirk Jordan
Dirk Jordan
CRCharles Robinson
Charles Robinson
BKBruce H. King
Bruce H. King
The cost of photovoltaic (PV) modules has declined by 85% since 2010. To achieve this reduction, manufacturers altered module designs and bill of materials; changes that could affect module durability and reliability. To determine if these changes have affected module durability, we measured the performance degradation of 834 fielded PV modules representing 13 module types from 7 manufacturers in 3 climates over 5 years. Degradation rates (Rd) are highly nonlinear over time, and seasonal variations are present in some module types. Mean and median degradation rate values of −0.62%/year and −0.58%/year, respectively, are consistent with rates measured for older modules. Of the 23 systems studied, 6 have degradation rates that will exceed the warranty limits in the future, whereas 13 systems demonstrate the potential of achieving lifetimes beyond 30 years, assuming Rd trends have stabilized.

17 November 2017 in IEEE Journal of Photovoltaics
Verified
Journal Article
Closed access
DJDirk C. Jordan
Dirk C. Jordan
CDChris Deline
Chris Deline
SJSteve Johnston
Steve Johnston
SRSteve R. Rummel
Steve R. Rummel
BSBill Sekulic
Bill Sekulic
RSRonald A. Sinton
Ronald A. Sinton
A silicon heterostructure photovoltaic system fielded for 10 years has been investigated in detail. The system has shown degradation, but at a rate similar to an average Si system, and still within the module warranty level. The power decline is dominated by a nonlinear V$_{\rm {oc}}$ loss rather than more typical changes in I$_{\rm {sc}}$ or Fill Factor. Modules have been evaluated using multiple techniques including: dark and light I–V measurement, Suns-V$_{\rm {oc}}$, thermal imaging, and quantitative electroluminescence. All techniques indicate that recombination and series resistance in the cells have increased along with a decrease of factor 2 in minority carrier lifetime. Performance changes are fairly uniform across the module, indicating changes occur primarily within the cells .

24 April 2022 in Progress in Photovoltaics: Research and Applications
Verified
Journal Article
Open access
DJDirk C. Jordan
Dirk C. Jordan
KAKevin Anderson
Kevin Anderson
KPKirsten Perry
Kirsten Perry
MMMatthew Muller
Matthew Muller
MDMichael Deceglie
Michael Deceglie
CDChris Deline
Chris Deline
In the PV Fleet Performance Data Initiative, high‐frequency data from commercial and utility‐scale photovoltaic (PV) systems have been collected to examine performance loss rates (PLRs) at a fleet scale. To date, performance data from more than 7.2‐gigawatt (GW) capacity, 1700 sites and 19,000 inverters—approximately equivalent to 6% to 7% of the entire US PV market—have been collected. An overall PLR of −0.75%/year was found, which is in line with historical and recent findings. Tracked silicon (Si) and cadmium telluride (CdTe) performed comparably with all fixed‐tilt systems. Higher PLRs were found for hotter temperature zones; cooler climates exhibit a median −0.48%/year loss, which increases to −0.88%/year in hotter climates. High‐efficiency module technologies showed median PLRs in line with conventional Si technologies but demonstrated markedly different PLR behavior when filtered only for low‐light conditions <600 W/m2. Causes for this technology‐dependent behavior are under investigation.