Yuki Okamoto

Dr. Yuki Okamoto

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2019 in Sensors and Actuators A: Physical
Verified
Journal Article
Open access
RRR. Ranga Reddy
R. Ranga Reddy
KKKeisuke Komeda
Keisuke Komeda
YOYuki Okamoto
Yuki Okamoto
ELEric Lebrasseur
Eric Lebrasseur
AHAkio Higo
Akio Higo
YMYoshio Mita
Yoshio Mita

20 April 2023 in Scientific Reports
Verified
Journal Article
Open access
PDF file
YOYuki Okamoto
Yuki Okamoto
TNThanh-Vinh Nguyen
Thanh-Vinh Nguyen
HTHidetoshi Takahashi
Hidetoshi Takahashi
YTYusuke Takei
Yusuke Takei
HOHironao Okada
Hironao Okada
MIMasaaki Ichiki
Masaaki Ichiki
This study investigates a cantilever-based pressure sensor that can achieve a resolution of approximately 0.2 mPa, over the frequency range of 0.1–250 Hz. A piezoresistive cantilever with ultra-high acoustic compliance is used as the sensing element in the proposed pressure sensor. We achieved a cantilever with a sensitivity of approximately 40 times higher than that of the previous cantilever device by realizing an ultrathin (340 nm thick) structure with large pads and narrow hinges. Based on the measurement results, the proposed pressure sensor can measure acoustic signals with frequencies as low as 0.1 Hz. The proposed pressure sensor can be used to measure low-frequency pressure and sound, which is crucial for various applications, including photoacoustic-based gas/chemical sensing and monitoring of physiological parameters and natural disasters. We demonstrate the measurement of heart sounds with a high SNR of 58 dB. We believe the proposed microphone will be used in various applications, such as wearable health monitoring, monitoring of natural disasters, and realization of high-resolution photoacoustic-based gas sensors. We successfully measured the first (S1) and second (S2) cardiac sounds with frequencies of 7–100 Hz and 20–45 Hz, respectively.

22 December 2023 in Science Advances
Verified
Journal Article
Open access
TSTakao Saiki
Takao Saiki
KSKeitaro Shimada
Keitaro Shimada
AIAyumu Ishijima
Ayumu Ishijima
HSHang Song
Hang Song
XQXinyi Qi
Xinyi Qi
Keiichi NakagawaKeiichi Nakagawa
Keiichi Nakagawa
Single-shot optical imaging based on ultrashort lasers has revealed nonrepetitive processes in subnanosecond timescales beyond the recording range of conventional high-speed cameras. However, nanosecond photography without sacrificing short exposure time and image quality is still missing because of the gap in recordable timescales between ultrafast optical imaging and high-speed electronic cameras. Here, we demonstrate nanosecond photography and ultrawide time-range high-speed photography using a spectrum circuit that produces interval-tunable pulse trains while keeping short pulse durations. We capture a shock wave propagating through a biological cell with a 1.5-ns frame interval and 44-ps exposure time while suppressing image blur. Furthermore, we observe femtosecond laser processing over multiple timescales (25-ps, 2.0-ns, and 1-ms frame intervals), showing that the plasma generated at the picosecond timescale affects subsequent shock wave formation at the nanosecond timescale. Our technique contributes to accumulating data of various fast processes for analysis and to analyzing multi-timescale phenomena as a series of physical processes.

21 March 2018 in Royal Society Open Science
Verified
Journal Article
Open access
DTDaigo Terutsuki
Daigo Terutsuki
HMHidefumi Mitsuno
Hidefumi Mitsuno
TSTakeshi Sakurai
Takeshi Sakurai
YOYuki Okamoto
Yuki Okamoto
ATAgnès Tixier-Mita
Agnès Tixier-Mita
RKRyohei Kanzaki
Ryohei Kanzaki
Field-effect transistor (FET)-based biosensors have a wide range of applications, and a bio-FET odorant sensor, based on insect (Sf21) cells expressing insect odorant receptors (ORs) with sensitivity and selectivity, has emerged. To fully realize the practical application of bio-FET odorant sensors, knowledge of the cell–device interface for efficient signal transfer, and a reliable and low-cost measurement system using the commercial complementary metal-oxide semiconductor (CMOS) foundry process, will be indispensable. However, the interfaces between Sf21 cells and sensor devices are largely unknown, and electrode materials used in the commercial CMOS foundry process are generally limited to aluminium, which is reportedly toxic to cells. In this study, we investigated Sf21 cell–device interfaces by developing cross-sectional specimens. Calcium imaging of Sf21 cells expressing insect ORs was used to verify the functions of Sf21 cells as odorant sensor elements on the electrode materials. We found that the cell–device interface was approximately 10 nm wide on average, suggesting that the adhesion mechanism of Sf21 cells may differ from that of other cells. These results will help to construct accurate signal detection from expressed insect ORs using FETs.

25 November 2019 in Journal of Microelectromechanical Systems
Verified
Journal Article
Open access
YOYuki Okamoto
Yuki Okamoto
HRHiroyuki Ryoson
Hiroyuki Ryoson
KFKoji Fujimoto
Koji Fujimoto
TOTakayuki Ohba
Takayuki Ohba
YMYoshio Mita
Yoshio Mita
The rapid development of microfluidic technology has increased the demand for the integration of driving circuits in the microfluidic devices. We have proposed a novel on-chip electroosmotic (EOF) micropump integrated with a high-voltage (HV) generator. The HV (49.8 V) generator is based on a Dickson charge pump, which is fabricated on a silicon-on-insulator (SOI) substrate by the standard CMOS process, and the isolation is achieved by MEMS post-processed deep trench isolation. The size of the 49.8 V generator is 425x353 μ m². The HV required for the successful operation of the micropump was generated by the integrated driving circuit with a low-voltage power supply. The maximum flow velocity and flow rate of the proposed EOF micropump were measured as 137 μ m/s and 167 nL/min, respectively when it was driven by the integrated 49.8 V generator. The efficiency of the micropump is demonstrated by comparing it with the previously reported micropumps. The proposed integration technique is reliable and effective, and potentially boosts the practical applications of lab-on-chip devices. [2019-0206]

19 May 2017 in Japanese Journal of Applied Physics
Verified
Journal Article
Closed access
PDF file
YMYoshio Mita
Yoshio Mita
ELEric Lebrasseur
Eric Lebrasseur
YOYuki Okamoto
Yuki Okamoto
FMFrédéfic Marty
Frédéfic Marty
RSRyota Setoguchi
Ryota Setoguchi
MDMatthieu Denoual
Matthieu Denoual
Since the 2000s, several countries have established micro- and nanofabrication platforms for the research and education community as national projects. By combining such platforms with VLSI multichip foundry services, various integrated devices, referred to as “CMOS-MEMS”, can be realized without constructing an entire cleanroom. In this paper, we summarize MEMS-last postprocess schemes for CMOS devices on a bulk silicon wafer as well as on a silicon-on-insulator (SOI) wafer using an open-access cleanroom of the Nanotechnology Platform of MEXT Japan. The integration devices presented in this article are free-standing structures and postprocess isolated LSI devices. Postprocess issues are identified with their solutions, such as the reactive ion etching (RIE) lag for dry release and the impact of the deep RIE (DRIE) postprocess on transistor characteristics. Integration with nonsilicon materials is proposed as one of the future directions.