Civil structural health monitoring (CSHM) has become significantly more important within the last decades due to rapidly growing construction volume worldwide as well as aging infrastructure and longer service lifetimes of the structures. The utilization of distributed fiber optic sensing (DFOS) allows the assessment of strain and temperature distributions continuously along the installed sensing fiber and is widely used for testing of concrete structures to detect and quantify local deficiencies like cracks. Relations to the curvature and bending behavior are however mostly excluded. This paper presents a comprehensive study of different approaches for distributed fiber optic shape sensing of concrete structures. Different DFOS sensors and installation techniques were tested within load tests of concrete beams as well as real-scale tunnel lining segments, where the installations were interrogated using fully-distributed sensing units as well as by fiber Bragg grating interrogators. The results point out significant deviations between the capabilities of the different sensing systems, but demonstrate that DFOS can enable highly reliable shape sensing of concrete structures, if the system is appropriately designed depending on the CSHM application.
27 January 2021 in Journal of Civil Structural Health Monitoring
Deformation monitoring and structural reliability assessment are key components in modern conventional tunneling. The state-of-the-art monitoring design is usually based on displacement measurements of geodetic targets using total stations paired with pointwise geotechnical sensors inside the tunnel lining. In recent years, distributed fiber optic sensing (DFOS) has become more popular in tunneling applications. DFOS measurements basically deliver internal strain and temperature distributions, but no direct relation to the tunnel shape’s behavior. This paper introduces a novel sensing and evaluation concept, which combines DFOS strain measurements and geodetic displacement readings for distributed shape assessment along curved structures, such as tunnel cross-sections. The designed system was implemented into shotcrete tunnel cross-sections as well as shaft linings and enables the determination of displacement profiles with high spatial resolution in the range of centimeters. Evaluations of continuous monitoring campaigns over several weeks as well as epoch-wise measurements performed by different DFOS sensing units in combination with stochastic analysis demonstrate the high potential of the developed approach and its capability to extend traditional monitoring methods in tunneling.
17 March 2022 in Journal of Civil Structural Health Monitoring
Structural integrity assessment is essential in modern tunneling to ensure safe construction works. State-of-the-art monitoring approaches like displacement readings of geodetic prisms are often limited in the spatial as well as the temporal measurement resolution, which is why potential safety hazards might be overlooked. This paper introduces a large-scale distributed fiber optic sensing (DFOS) network inside the tunnel lining of a highway tunnel currently under construction in Austria. The tunnel construction site faces challenging geological conditions with loose rock excavation near to the surface with minimal covering. Fiber optic sensing cables were installed along both tunnel tubes to autonomously monitor 13 cross-sections of the primary shotcrete lining, about 220 m of the tunnel in longitudinal direction and 10 cross-sections of the secondary inner lining. Measurements are continuously evaluated and autonomously transferred to the geotechnical engineer on-site for further analysis. While the construction works are ongoing, alerts are additionally sent out automatically, if pre-defined thresholds are exceeded. The paper outcomes demonstrate that the innovative DFOS system immediately responds to structural modifications and, indeed, increases safety at the construction site.
7 June 2020 in Journal of Civil Structural Health Monitoring
Efficient and economic foundations are essential to ensure the long-term integrity of structures. Driven ductile piles offer a safe and quick solution for foundations, which can be individually customized to changing soil conditions. Geotechnical load tests on a small subset of piles can be performed at large construction sites to examine the bearing capacity for optimization purposes. Arising deformations during these statical tests are usually measured using electrical sensors at the top, which, however, do not deliver information about the stress distribution along the pile. This paper presents a fiber optic monitoring approach, which provides distributed strain profiles with a spatial resolution of up to 10 mm along driven ductile piles. The high measurement resolution of about $$1~{\mu}m/m$$ enables the detection of local effects in the load transfer from the pile to the surrounding grout and soil. The critical sensor installation on-site as well as results of various field applications with pile lengths of up to 25 m are presented. Verification measurements at the pile’s head and internal measurements of strain gauges prove the suitability of the developed monitoring approach and demonstrate the high potential of distributed fiber optic sensing for applications in soil mechanics.
Predictive maintenance and safety assessment during the construction and operational phase are becoming more and more important in modern tunnelling. However, traditional measurement methods are often time-consuming, expensive and partially require an interruption of the tunnel traffic. In this article, we present a tunnel monitoring approach based on distributed fibre optic sensing (DFOS), which delivers hundreds of strain and temperature sensing points inside the structure and gives completely new information about the behaviour of the tunnel lining. Measurements can be performed automatically without the need of access to the tunnel and hence, monitoring can be made without disturbing the tunnel construction or operation. The developed system was installed within the shotcrete tunnel lining of a railway tunnel under construction in Austria. In addition to the critical installation process, this article discusses the main monitoring results and compares them to conventional measurements.